Summary of the content on the page No. 1
Owner’s
Manual
Portable Air Conditioner
Model CPLMB-12000E
It is important that
you read these
instructions before
using your new
purchase and we
strongly recommend
that you keep them
in a safe place for
future reference.
™
Innovative AutoDrain NanoMist Technology
Patent Pending
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Table of Contents THANK YOU ……………………………………………………………………… 2 Energy Saving Tips …………………………………………………………… 2 SPECIFICATIONS ………………………………………………………………… 3 BEFORE USE ……………………………………………………………………… 4 THE CPLMB UNIT / PARTS ……………………………………………………… 5 AUTODRAIN NANOMIST TECHNOLOGY™ ASSEMBLY ……………………… 6 INSTALLATION OF THE WINDOW KIT ………………………………………… 7 Window Kit Installation ……………………………………………………… 7 INSTALLATION …………………………………………………………………… 8 OPERATION ……………………………………………………………………… 9 Turning the Unit On ……………
Summary of the content on the page No. 4
Thank You! Thank you for purchasing an AMCOR Portable Air Conditioner. AMCOR is a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Portable Air Conditioner offers you. AMCOR has specialized in complete indoor environment control, manufacturing world-class air conditioners, dehumidifiers and air purifiers with innovative technology
Summary of the content on the page No. 5
Specifications Model CPLMB-12000E Cooling Capacity 12,000 BTU/h Cooling Power Consumption 1,100 W / 9.8 A Power Supply 115V / 60Hz / 1 Phase Dehumidification 80 pints / Day Recommended room size Up to 400 sq. ft. Refrigerant R-22 Compressor Rotary Fan Speeds 3 (2 + 1 Turbo) Thermostat 64º - 90º F Timer 0-24 hours Dimensions 20”W x 16”D x 33”H Weight 75 lbs. REMARKS: The cooling capacity of the unit may be affected by the height of the ceiling, quality of insulation, number of windows, etc. Su
Summary of the content on the page No. 6
Before Use IMPORTANT! • Leave the unit in an upright position for at least 2 hours before use. • Always place the unit on an even surface. • The power cord has a built-in L.C.D.I. (Leakage Current Detection and Interruption) circuit breaker for added safety. If the power supply is interrupted, please press the reset button to reconnect the unit to the power source. The green light should be on. • Make sure the unit is connected to a correctly grounded power supply. • For proper operat
Summary of the content on the page No. 7
ON/OFF UP FAN DOWN The CPLMB Unit A i r O u t l e t C o n t r o l P a n e l U p p e r a i r i n l e t C a r r y i n g H a n d l e E x h a u s t A i r o u t l e t L o w e r a i r i n l e t C a s t e r W a t e r s t o p p e r / W h e e l s d r a i n c a p Parts Air Filter (Pre-installed) D r a i n P a n E x h a u s t H o s e R e m o t e C o n t r o l Spiral Water Pipe S l i d e B a r A d j u s t a b l e S l i d e B a r I n s u l a t i o n S t r i p s
Summary of the content on the page No. 8
TM AutoDrain NanoMist Technology Assembly Put spiral water Attach Window 1 2 pipe into hot air Slide Bar flexible hose. Connector to Exhaust Hose by twisting as shown. Connect the Turn the 3 4 connector female half of the quick connector 90 degrees at the end of the clockwise until it is locked in place. spiral water pipe to the male part in the hot air outlet pipe. Assemble the Clip on the 5 hot air hose on 6 water atomizer the unit. at the end of the spiral pipe to the hol
Summary of the content on the page No. 9
TM AutoDra Inis n N tallaan to io M n o ist T f te hc e W hno in lo dg oy w K A itssembly In order for this unit to function properly, it must be vented to the outside. Fitting the Exhaust Hose through a window is easy. Please see below. Adjustable Slide Bar Slide Bar Connector Exhaust Hose Window Kit Installation: 1. Extend Exhaust Hose at least 6" and insert it into back of the unit, tightening into place by turning it clockwise. 2. Attach Slide Bar Connector to the other end of the Hose
Summary of the content on the page No. 10
Installation WARNING! The length of the exhaust pipe is specially designed according to the specification of this product. Do not extend it with your own hose, as this could cause the unit to malfunction 8
Summary of the content on the page No. 11
Operation IMPORTANT: The air conditioner should be left in an upright position for at least two hours Reset Button A. Turning the Unit On: 1. Plug the unit into a working electrical outlet. 2. Make sure the green light on the plug is on. Test Button (If not, press the Reset button.) 3. Press the unit’s ON/OFF Button on the LCD display. Green Light It may take a few minutes before cold air is dispersed. 4. Adjust FAN Speed by pressing the FAN Button until the preferred fan speed is reac
Summary of the content on the page No. 12
Operation Timer The TIMER function allows you to program the time the unit turns on and turns off. TO SET THE TIMER: • Press the TIME button briefly, the 2 hour digits will flash. • Press the UP or DOWN button to adjust the hour. • Press the TIME button again. The 2 minute digits will flash. • Press the UP or DOWN button briefly to adjust the minutes. • The TIME is set. After 10 seconds the time display returns. Programming the Timer for ON: • Perform the standard steps as described above.
Summary of the content on the page No. 13
Operation The unit will operate daily according to the timer setting, unless changed. After a power failure, or after the unit has been unplugged, you will have to program the timer settings again. Canceling the Timer Setting In order to cancel the timer programming press the TIME button. Sleep Mode The SLEEP MODE gradually adjusts the temperature of the unit 4 degrees upward, over a 3 hour period, to meet the needs of a body at rest. To activate the SLEEP MODE: • Ensure the unit is operating
Summary of the content on the page No. 14
Remote Control To Operate the Remote Control: Insert batteries by pulling down on front cover (See fig. 1). Be sure the remote is pointed at the unit at all times. 1. To Set the Clock: 10:09 • Press the TIME button for 3 seconds. 72 F ϒ • The hour digits will flash. Press UP or DOWN to adjust the hour. • Press the TIME button. The minute digits will flash. ON/OFF UP Press UP or DOWN to adjust the minutes. FAN DOWN • Press the TIME button when finished. TIME 2. To Turn Unit ON: • Pres
Summary of the content on the page No. 15
Emptying the Internal Water Container Note: There are two instances where draining the internal water container may be recommended: 1. In the unlikely event that the Container Full Light on the LCD display flashes 2. Prior to storage of unit. When the internal water container is full, the back light on the LCD display flashes. The unit will shut off automatically, and must be drained before it will restart. To Drain the Unit: • Switch off the unit and remove the plug from the wall so
Summary of the content on the page No. 16
Maintenance Always unplug the unit from the wall before performing any maintenance. • Make sure the unit is drained before moving. Cleaning the Unit: • Only use a soft damp cloth. • Never use chemicals, oil-based products, detergents, or other cleaning solutions. These could damage the cabinet. Cleaning the “Upper” Filter: • Slide out the filter holder from the unit. • Separate the filter fixer from the filter holder (see fig. 1). • Remove the active carbon filter (black) and slide o
Summary of the content on the page No. 17
Troubleshooting Never try to repair or dismantle the air conditioner yourself. Tampering with the unit may result in the loss of warranty and can endanger the user and property. Problem Cause Solution The Air Condi- Windows or doors are open. Close doors and windows. tioner Does Not The filter is dirty. Clean or replace filter. Function Properly Air inlet or air outlet is blocked. Remove blockage. Room temperature lower than the Lower temperature selected. selected value. The Unit Does The ov
Summary of the content on the page No. 18
Don’t forget to register your Amcor purchase online, and view our broad selection of innovative products. www.amcorgroupusa.com 16
Summary of the content on the page No. 19
Summary of the content on the page No. 20
One Year Limited Warranty (5 Years for Compressor Only) Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the United States that the Amcor product with which this warranty is enclosed is free from defects in materials and workmanship. Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair, free of charge, all defective parts, for a period of one (1) year from date of original purchase. (5 years for Compressor Onl