York GUA user manual

User manual for the device York GUA

Device: York GUA
Category: Air Conditioner
Manufacturer: York
Size: 0.28 MB
Added : 2/7/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York GUA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York GUA.

For your convenience

If looking through the York GUA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York GUA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York GUA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York GUA User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York GUA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York GUA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

036-21145-003 Rev. A (0403)

DESCRIPTION
R
These cooling and heat pump coils are designed to be
installed with UPG furnaces and to be matched with UPG
cooling and heat pump outdoor units. All coils are available
as sweat-connect models for your convenience and ease of
matching.
Heating Air Conditioning
Upflow Coils - Available in high-capacity models to match
any system and upflow furnace. Models available with factory
installed TXV or orifice metering system.
TECHNICAL GUIDE
Multi-Positi

Summary of the content on the page No. 2

036-21145-003 Rev. A (0403) * COOLING CAPACITY - Coil Only MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING ENTERING RATED PRESSURE °F / PSIG MODEL AIR °F CFM (WET BULB) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW "A" TYPE 72 35.6 32.5 29.0 25.2 67 32.9 29.7 26.3 22.7 G1FA024S14(T) 675 G1UA024S14 62 27.0 23.9 20.7 17.4 57 21.9 19.0 15.9 12.4 72 35.6 32.5 29.0 25.2 G1FA024S17(T) 67 32.9 29.7 26.3 22.7 850 G1UA024S17 62 27.0 23.9 20.7 17.4 57 21.9 19.0 15.9 12.4 72 38.9 35.4 31.6 27.6 G1FA030S1

Summary of the content on the page No. 3

036-21145-003 Rev. A (0403) * COOLING CAPACITY - COIL ONLY Entering Air °F MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG Model Coil Rated CFM (Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION 72 36.3 33.0 29.5 25.6 G2FD024(S,H)14(T) 67 33.4 30.2 26.7 23.1 850 G2FD024(S,H)17(T) 62 27.4 24.3 21.0 17.7 57 22.2 19.3 16.2 12.6 72 41.5 37.8 33.7 29.5 G2FD030(S,H)17(T) 67 36.2 32.4 28.6 24.5 1025 G2FD035(S,H)14(T) 62 29.1 25.3 24.0 19.2 57 24.1 21.

Summary of the content on the page No. 4

036-21145-003 Rev. A (0403) * COOLING CAPACITY - COIL ONLY MBH@ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE °F / PSIG MODEL COIL RATED CFM ENTERING AIR °F (WET BULB) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UNCASED UPFLOW 72 27.4 25.0 22.3 19.4 67 25.3 22.9 20.3 17.5 G1NA024S17G 800 62 20.8 18.4 15.9 13.4 57 16.9 14.6 12.2 9.4 72 35.2 32.0 28.6 24.8 67 32.4 28.6 25.3 21.9 G1NA030S17H 1000 62 26.6 23.6 21.5 18.7 57 25.2 22.7 20.2 17.6 72 39.6 36.0 32.1 27.9 67 36.4 33.2 29.5 25.7 G1NA030S17K

Summary of the content on the page No. 5

036-21145-003 Rev. A (0403) STATIC PRESSURE VS. AIRFLOW (BASED ON WET COIL) MODEL AIRFLOW WET COIL MODEL AIRFLOW WET COIL UPFLOW CASED "A" TYPE CASED "A" TYPE MULTI-POSITION 600 0.12 600 0.10 G1FA024S14(T) 800 0.21 G2FD024(S,H)14(T) 800 0.19 G1UA024S14 1000 0.33 1000 0.29 600 0.10 600 0.08 G1FA024S17(T) 800 0.17 G2FD024(S,H)17(T) 800 0.15 G1UA024S17 1000 0.27 1000 0.23 800 0.14 800 0.22 G1FA030S14(T) 1000 0.22 G2FD035(S,H)14(T) 1000 0.34 G1UA030S14 1200 0.31 1200 0.49 1000 0.21 800 0.18 G1FA036S

Summary of the content on the page No. 6

036-21145-003 Rev. A (0403) PHYSICAL DATA REFRIG. STD. FACE FIN OPERATING ROWS TUBE TUBE FIN EXPANSION MODEL APPLICATION CONN. ORIFICE AREA PER COIL SIZE WEIGHT DEEP GEOMETRY DIA. TYPE DEVICE TYPES SIZE (SQ. FT.) IN. (LBS.) UPFLOW "A" TYPE G1FA024S14 59 2.92 2 14 (2) 12 x 17.5 Orifice 30 G1FA024S14T 59 2.92 2 14 (2) 12 x 17.5 TXV 30 G1FA024S17 59 2.92 2 14 (2) 12 x 17.5 Orifice 31 G1FA024S17T 59 2.92 2 14 (2) 12 x 17.5 TXV 31 G1FA030S14 65 3.40 2 14 (2) 12 x 17.5 Orifice 38 G1FA030S14T 65 3.40 2

Summary of the content on the page No. 7

036-21145-003 Rev. A (0403) PHYSICAL DATA (Continued) REFRIG. STD. FACE FIN OPERATING ROWS TUBE TUBE FIN EXPANSION MODEL APPLICATION CONN. ORIFICE AREA PER COIL SIZE WEIGHT DEEP GEOMETRY DIA. TYPE DEVICE TYPES SIZE (SQ. FT.) IN. (LBS.) FULL CASED "A" TYPE MULTI-POSITION G2FD024(S,H)14 61 3.40 2 14 (2) 14 x 17.5 Orifice 37 G2FD024H14T 61 3.40 2 14 (2) 14 x 17.5 TXV 37 G2FD024(S,H)17 61 3.40 2 14 (2) 14 x 17.5 Orifice 42 G2FD024H17T 61 3.40 2 14 (2) 14 x 17.5 TXV 42 G2FD035(S,H)14 65 3.89 2 14 (2)

Summary of the content on the page No. 8

036-21145-003 Rev. A (0403) DIMENSIONS G1FA UPFLOW CASED COIL 20-7/8 C B 22 A D 20-3/16 REFRIGERANT DIMENSIONS — INCHES CONNECTIONS MODEL LINE SIZE AB C D E F G LIQUID VAPOR 14-1/2 16 13-3/8 13-1/2 - - - 3/8 5/8 G1FA024S14(T) G1FA024S17(T) 17-1/2 16 16-3/8 16-1/2 - - - 3/8 5/8 G1FA030S14(T) 14-1/2 18 13-3/8 13-1/2 - - - 3/8 3/4 G1FA036S14(T) 14-1/2 22-1/4 13-3/8 13-1/2 - - - 3/8 3/4 G1FA036S17(T) 17-1/2 19-1/2 16-3/8 16-1/2 - - - 3/8 3/4 G1FA036S21(T) 21 19-1/2 19-7/8 20 - - - 3/8 3/4 G1FA048S17

Summary of the content on the page No. 9

036-21145-003 Rev. A (0403) G1UA UPFLOW CASED COIL B 10 20-7/8 C 22 A 20-3/16 D REFRIGERANT DIMENSIONS — INCHES CONNECTIONS MODEL LINE SIZE AB C D E F G LIQUID VAPOR G1UA024S14 14-1/2 14-1/2 13-3/8 13-1/2 - - - 3/8 5/8 G1UA024S17 17-1/2 14 16-3/8 16-1/2 - - - 3/8 5/8 G1UA030S14 14-1/2 16-5/8 13-3/8 13-1/2 - - - 3/8 3/4 G1UA036S14 14-1/2 19-7/8 13-3/8 13-1/2 - - - 3/8 3/4 G1UA036S17 17-1/2 18-3/8 16-3/8 16-1/2 - - - 3/8 3/4 G1UA036S21 21 17-7/8 19-7/8 20 - - - 3/8 3/4 G1UA048S17 17-1/2 25-5/8 16

Summary of the content on the page No. 10

036-21145-003 Rev. A (0403) G1HD HORIZONTAL DUCT COIL 3-3/4 A 2-5/8 1-3/8 LIQ UID CONN. D 3/4 MPT SECONDARY VAPOR CONN. DRAIN CONN. 3/4 MPT PRIMARY DRAIN CONN. B 7/8 1-3/4 1 -3/8 1-7/8 C 4 -1/8 OUTLET SAME SIZE A S INLET (ALL FLANGES 3/4" T HICK ) 5 - 5/8 DIMENSIONS — INCHES REFRIGERANT CONNECTIONS MODEL LINE SIZES AB C D E F G LIQUID VAPOR G1HD024 28-3/4 24 23-3/4 21-5/8 - - - 3/8 5/8 G1HD036 28-3/4 24 23-3/4 21-5/8 - - - 3/8 3/4 G1HD048 28-3/4 28 23-3/4 25-5/8 - - - 3/8 7/8 G1HD060 3

Summary of the content on the page No. 11

036-21145-003 Rev. A (0403) G2FD MULTI-POSITION “A” COIL D E (Available with or without a factory installed horizontal drain pan). 3/4” FLANGE C G F B A BOTTOM OPENING DIMENSIONS — INCHES REFRIGERANT CONNECTIONS MODELS QUICK-CONNECT LINE SIZE A BCD E F G LIQUID VAPOR LIQUID VAPOR G2FD024(S,H)14(T) 14-1/2 23 13-3/8 13-1/2 — — 5/8 G2FD024(S,H)17(T) 17-1/2 23 16-3/8 16-1/2 — — 5/8 G2FD035(S,H)14(T) 14-1/2 23 13-3/8 13-1/2 — — 5/8 G2FD030(S,H)17(T) 17-1/2 23 16-3/8 16-1/2 — — 5/8 G2FD036(S,H)17(T) 1

Summary of the content on the page No. 12

G1NA COIL C B A DIMENSIONS — INCHES REFRIGERANT CONNECTIONS MODELS QUICK-CONNECT LINE SIZE A BCD E F G LIQUID VAPOR LIQUID VAPOR G1NA024S17G 16-1/4 14-5/8 — — — — — — 3/4 G1NA030S17H 16-1/4 15-3/4 — — — — — — 3/4 G1NA030S17K 16-1/4 17-7/8 — — — — — — 3/4 19-7/8 G1NA036S17J 16-1/4 19-5/8 — — — — — — 3/4 G1NA036S17L 16-1/4 19-7/8 — — — — — — 3/8 7/8 G1NA036S21C 19-3/8 19-1/8 — — — — — — 3/4 G1NA042S24W 21-3/8 20-3/8 23-7/8 — — — — — — 7/8 G1NA048S21D 19-3/8 19-7/8 19-3/8 — — — — — — 7/8 G1NA060S24


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21