Summary of the content on the page No. 1
H8S/2138 Series
TQFP-80C
User System Interface Cable
(HS2138ECN61H)
for E6000 Emulator
User’s Manual
HS2138ECN61HE(C)
Summary of the content on the page No. 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Summary of the content on the page No. 3
Preface Thank you for purchasing this user system interface cable (HS2138ECN61H) for the Renesas’s original microcomputer H8S/2138 series. The HS2138ECN61H is a user system interface cable that connects an H8S/2148, H8S/2138, H8S/2128 series E6000 emulator (HS2148EPI61H; hereinafter referred to as the emulator) to the IC socket for a TQFP-80C package (package code: TFP-80C) for the H8S/2138 series MCU on the user system. i
Summary of the content on the page No. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ..........................
Summary of the content on the page No. 5
Section 1 Configuration CAUTION Use an IC149-080-058-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-80C package IC socket on the user system. Figure 1 shows the configuration of the HS2138ECN61H user system interface cable for the TFP-80C package. 1
Summary of the content on the page No. 6
To emulator station Cable body Screws (M2.6 x 12 mm) with flat washers Screws (M2.6 x 8 mm) (for fastening cable head) with flat washers Socket cover Cable head IC socket User system Figure 1 HS2138ECN61H User System Interface Cable 2
Summary of the content on the page No. 7
Table 1 lists the HS2138ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2138ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP-80C package 4 Socket cover 1 For installing an TFP-80C packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 8 mm) 4 For installing an TFP-80C packaged MCU (with four flat washers) 7 Docu
Summary of the content on the page No. 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect t
Summary of the content on the page No. 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow
Summary of the content on the page No. 10
2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC soc
Summary of the content on the page No. 11
Screws (M2.6 x 12 mm), flat washer Cable head Pin 1 IC socket (IC149-080-058-B51 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) User system Figure 3 Connecting User System Interface Cable to User System 7
Summary of the content on the page No. 12
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
Summary of the content on the page No. 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TFP-80C package (IC149-080-058-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 15.10 (min.) 11.80 (max.) 0.50 19 = 9.50 0.05 0.50 0.05 0.30 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad 9 0
Summary of the content on the page No. 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10
Summary of the content on the page No. 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-080-058-B51 User system Unit: mm manufactured by Tolerance: –0.5 mm YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11
Summary of the content on the page No. 16
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may brea
Summary of the content on the page No. 17
Screws (M2.6 x 8 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-080-058-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System 13
Summary of the content on the page No. 18
Section 4 Verifying Operation 1. When using the E6000 emulator (HS2148EPI61H) for the H8S/2148, H8S/2138, H8S/2128 series, turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the
Summary of the content on the page No. 19
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS2148EPI61H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca