York DNH018 user manual

User manual for the device York DNH018

Device: York DNH018
Category: Air Conditioner
Manufacturer: York
Size: 0.83 MB
Added : 6/10/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York DNH018. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York DNH018.

For your convenience

If looking through the York DNH018 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York DNH018 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York DNH018 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York DNH018 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York DNH018 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York DNH018. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

036-21233-002-A-0903

FLEXIBLE LIGHT COMMERCIAL UNIT
GENERAL
®
YORK’s Champion package units are designed to handle
applications ranging from residential to light commercial and
TECHNICAL GUIDE
®
any in between. The Champion is a unit that gives you the
®
flexibility and choices you need in today’s market.
CHAMPION PLUS
FEATURING
SINGLE PACKAGE GAS/ELECTRIC
AIR COOLED AIR CONDITIONERS  COOLING/GAS HEATING UNITS (NATURAL GAS OR
PROPANE)
1-1/2 THROUGH 5 NOMINAL TON  LOW PROFILE
 QUIET O

Summary of the content on the page No. 2

036-21233-002-A-0903 TABLE OF CONTENTS DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LIST OF TABLES STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3 Tbl. # Pg. # FIELD-INSTALLED ACCESSORIES. . . . . . . . . . . . . 4 1 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TYPICAL WIRING DIAGRAM NOTES . . . . . . . . . . 28 2 RATINGS COOLING/GAS HEATING . . . . . . . . . . . . . . 7 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . 29 3 DNH018

Summary of the content on the page No. 3

036-21233-002-A-0903 CONDENSATE PAN - A non-corrosive, long-lasting, water- DESCRIPTION tight pan is positioned below the evaporator coil to collect and These packaged cooling/heating air conditioners are drain all condensate. Less collection of stagnate condensate designed for outdoor installation. Only utility and duct con- will build-up. The condensate pan conforms to ASHRAE 62- nections are required at the point of installation. 89 standards (Ventilation for Acceptable Indoor Air Quality)

Summary of the content on the page No. 4

036-21233-002-A-0903 FAN SYSTEM - All models operate over a wide range of EASY SERVICE ACCESS - A large, single panel covers the design conditions with a 3-speed direct-drive fan motor. electrical and gas controls makes servicing easy. The blower These units easily match all types of applications and pro- compartment has an additional large panel with a built-in vides greater on site flexibility to match comfort requirement. handle tab. Removing this panel will allow the blower assem- Single

Summary of the content on the page No. 5

036-21233-002-A-0903 HAIL GUARD KIT - Kit contains protective grilles made of openings on the base unit. Transition is from side square duct expanded aluminum with full perimeter frame. Sloped hoods opening to 14" round duct opening. are also included to assure maximum protection. ROOF CURBS - NRCA approved curbs provide proper fit to ANTI SHORT CYCLE TIMER - Automatically prevents the base unit for rooftop installations. Curbs are designed to be compressor from restarting for 5 minutes after

Summary of the content on the page No. 6

036-21233-002-A-0903 TABLE 1: PHYSICAL DATA DNH MODEL 018 024 030 036 042 048 060 CENTRIFUGAL BLOWER (Dia. x W. in.) 10 X 8 10 X 8 10 X 8 11 x 10 11 x 10 12 x 11 12 x 11 EVAPORATOR BLOWER FAN MOTOR HP (3 Speed) 1/2 1/2 1/2 3/4 3/4 3/4 1 ROWS DEEP 22 33 33 3 EVAPORATOR FINS PER INCH 13 15 13 13 13 16 16 COIL FACE AREA (Sq. Ft.) 3.5 3.5 3.5 3.5 4.5 4.5 4.5 PROPELLER DIA. (in.) 22222222 2222 22 CONDENSER FAN MOTOR HP 1/4 1/4 1/4 1/4 1/4 1/3 1/3 FAN NOM. CFM TOTAL 1,800 2,200 2,400 2,400 2,400 3,00

Summary of the content on the page No. 7

036-21233-002-A-0903 TABLE 2: RATINGS COOLING/GAS HEATING 1 GAS HEAT CAPACITY / EFFICIENCIES NET COOLING CAPACITY SOUND MODEL TEMP. RATING 4 INPUT OUTPUT NUMBER OF AFUE DNH 3 MBH 2 RISE SEER (dbels) (MBH) (MBH) BURNERS (%) (°F) RANGE 018N03606 17.4 12.0 80 45 36 80.2 2 25 - 55 024N03606 23.8 12.4 81 45 36 80.2 2 25 - 55 024N05606 23.8 12.4 81 70 56 80.2 3 30 - 60 030N03606 28.0 12.0 80 45 36 80.2 2 25 - 55 030N03625 28.0 12.0 80 45 36 80.2 2 25 - 55 030N03646 28.0 12.0 80 45 36 80.2 2 25 - 55 03

Summary of the content on the page No. 8

036-21233-002-A-0903 TABLE 3: DNH018 COOLING CAPACITIES - 1-1/2 TON AIR ON EVAPORATOR COIL TEMPERATURE 450 CFM 525 CFM 600 CFM 675 CFM 750 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 16.0 15.0 13.5 13.7 18.0 16.8 15.2 15.4 19.9 18.7 16.8 17.1 20.3 19.0 17.1 17.4 20.7 19.4 17.5 17.7 MBH TOTAL POWER 1.61 1.61 1.60 1.60 1.62 1.61 1.61 1.61 1.62 1.61 1.61 1.61 1.64 1.63 1.63 1.63 1.66 1.65 1.65 1.65 INPUT kW 86 9.0 11.6

Summary of the content on the page No. 9

036-21233-002-A-0903 TABLE 4: DNH024 COOLING CAPACITIES - 2 TON AIR ON EVAPORATOR COIL TEMPERATURE 600 CFM 700 CFM 800 CFM 900 CFM 1000 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 23.1 22.8 20.2 19.7 24.5 24.1 21.4 20.9 25.9 25.5 22.6 22.0 25.3 25.0 22.1 21.6 24.8 24.4 21.6 21.1 MBH TOTAL POWER 2.00 1.99 1.98 1.97 2.03 2.02 2.01 2.00 2.06 2.05 2.04 2.03 2.10 2.09 2.08 2.07 2.15 2.14 2.12 2.11 INPUT kW 86 12.1 16.6 19

Summary of the content on the page No. 10

036-21233-002-A-0903 TABLE 5: DNH030 COOLING CAPACITIES - 2-1/2 TON AIR ON EVAPORATOR COIL TEMPERATURE 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 27.2 26.8 24.1 24.0 28.5 28.1 25.3 25.2 29.8 29.4 26.4 26.4 29.4 29.0 26.1 26.0 29.0 28.6 25.7 25.6 MBH TOTAL POWER 2.35 2.34 2.32 2.32 2.40 2.39 2.37 2.36 2.44 2.43 2.41 2.40 2.52 2.51 2.49 2.48 2.60 2.59 2.57 2.56 INPUT kW 86 17

Summary of the content on the page No. 11

036-21233-002-A-0903 TABLE 6: DNH036 COOLING CAPACITIES - 3 TON AIR ON EVAPORATOR COIL TEMPERATURE 900 CFM 1,050 CFM 1,200 CFM 1,300 CFM 1,400 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 35.9 33.6 31.7 31.6 38.4 35.9 33.9 33.8 40.9 38.3 36.1 36.0 41.5 38.9 36.6 36.6 42.1 39.5 37.2 37.2 MBH TOTAL POWER 3.14 3.09 3.10 3.17 3.16 3.11 3.12 3.18 3.18 3.13 3.14 3.20 3.12 3.07 3.08 3.14 3.07 3.02 3.03 3.09 INPUT kW 86 19.7

Summary of the content on the page No. 12

036-21233-002-A-0903 TABLE 7: DNH042 COOLING CAPACITIES - 3-1/2 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,050 CFM 1,225 CFM 1,400 CFM 1,575 CFM 1,750 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 38.6 38.4 34.0 33.3 42.1 41.8 37.0 36.3 45.5 45.3 40.1 39.2 45.3 45.0 39.9 39.1 45.1 44.8 39.7 38.9 MBH TOTAL POWER 4.05 3.83 3.95 3.91 4.01 3.79 3.92 3.87 3.98 3.76 3.88 3.84 4.12 3.90 4.02 3.98 4.27 4.03 4.16 4.12 INPUT kW 8

Summary of the content on the page No. 13

036-21233-002-A-0903 TABLE 8: DNH048 COOLING CAPACITIES - 4 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,200 CFM 1,400 CFM 1,600 CFM 1,800 CFM 2,000 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 50.8 47.4 43.1 42.8 52.8 49.3 44.8 44.5 54.8 51.2 46.5 46.2 55.5 51.9 47.1 46.8 56.2 52.5 47.7 47.4 MBH TOTAL POWER 4.01 3.98 4.02 3.98 4.06 4.03 4.07 4.03 4.11 4.08 4.12 4.08 4.24 4.20 4.25 4.20 4.36 4.33 4.37 4.33 INPUT kW 86 30.

Summary of the content on the page No. 14

036-21233-002-A-0903 TABLE 9: DNH060 COOLING CAPACITIES - 5 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,700 CFM 1,800 CFM 1,900 CFM 2,000 CFM 2,100 CFM OF AIR ON WB °FWB °FWB °FWB °FWB °F CONDENSER COIL 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 NET CAP. 66.863.158.257.068.264.459.458.269.5 65.660.659.369.365.460.359.169.065.160.158.9 MBH TOTAL POWER 5.06 4.96 5.02 4.83 5.13 5.03 5.10 4.90 5.21 5.11 5.17 4.97 5.33 5.24 5.30 5.09 5.46 5.36 5.43 5.22 INPUT kW 86 42.8 53.5 58.2 57.0

Summary of the content on the page No. 15

036-21233-002-A-0903 1 TABLE 10: SIDE SUPPLY AIR PERFORMANCE - 208 VOLT EXTERNAL STAIC PRESSURE - IWG MODEL # .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 DNH MTR (Cooling/ SPD Heating) HI -- -- -- -- --- - - - - - 608358465326 - - 018 MED - - - - - - - - - - 695 263 615 246 509 226 - - - - - - LOW 743 243 700 235 657 226 614 218 549 207 483 195 - - - - - - - - - - HI - - - - - - - - - - 984 443 894 422 751 390 608 358 - - - - 024 MED 994 333 947 321 901 309 854 297 774 280 695 263 615 246 - -

Summary of the content on the page No. 16

036-21233-002-A-0903 1 TABLE 11: SIDE SUPPLY AIR BLOWER PERFORMANCE - 230, 460 & 575 VOLT EXTERNAL STATIC PRESSURE - IWG MODEL # .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 DNH MTR (Cooling/ SPD Heating) HI - --- --- --- --- --- 688454568436 - - 018 MED - --- --- --- -- 706280588257470234 -- - - LOW - - - - - - 721 255 651 241 581 226 511 212 - - - - - - - - HI - --- --- --- -- 929491809473688454 -- - - 024 MED - - - - 999 353 944 338 865 319 785 299 706 280 - - - - - - - - LOW998372906333813

Summary of the content on the page No. 17

036-21233-002-A-0903 1 TABLE 12: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 208 VOLT EXTERNAL STATIC PRESSURE - IWG MODEL # .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 DNH MTR (Cooling/ SPD Heating) HI -- ---- ---- - - --- - 547322419293 -- 018 MED - - ---- ---- 625237554221458203 --- --- LOW 669219630211591204553196494186435176 --- ---- --- HI -- ---- ---- 886398805380676351547322 - --- 024 MED 895300853289811278769267697252625237554221 - ---- --- LOW 669219630211591204553196 - - - - --- ---- ---

Summary of the content on the page No. 18

036-21233-002-A-0903 1 TABLE 13: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 230, 460 & 575 VOLTS EXTERNAL STATIC PRESSURE - IWG MODEL # .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 DNH MTR (Cooling/ SPD Heating) HI - --- -- --- -- --- - - 620409511392 - - 018 MED - --- -- --- -- - 635252529231423423 - - - - LOW - - - - - - 649 230 586 217 523 204 460 191 - - - - - - - - HI - --- -- --- -- - 836442728425620409 - - - - 024 MED - - - - 899 318 850 304 778 287 707 269 635 252 - - - - - - - - LOW 898 3

Summary of the content on the page No. 19

036-21233-002-A-0903 1 TABLE 15: ADDITIONAL STATIC PRESSURE RESISTANCE 3-1/2 - 5 TON (DNH042 - 060) RESISTANCE, IWG DESCRIPTION CFM 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000 WET EVAPORATOR COIL .02 .03 .04 .05 .06 .07 .07 .08 .09 .09 2 .02 .02 .02 .03 .03 .04 .04 .04 .05 .05 ECONOMIZER FILTER FRAME KIT .04 .04 .05 .05 .06 .07 .08 .09 .10 .11 1. Deduct these resistance values from the available external static pressure shown in Table 10, 11, 12, and 13 2. The pressure through th

Summary of the content on the page No. 20

036-21233-002-A-0903 TABLE 16: ELECTRICAL DATA VOLTAGE SUPPLY MAX. MAX. COND. COMPRESSOR 1 AIR MINIMUM HACR UNIT LIMITATIONS FUSE MODEL POWER FAN TRANSFORMER BLOWER CIRCUIT BREAKER POWER SIZE, DNH SUPPLY MOTOR, SIZE (VA) MOTOR AMPACITY SIZE, FACTOR 2 MIN. MAX. RLA LRA FLA AMPS FLA AMPS 018 208/230-1-60 187 253 7.1 48 1.1 2.6 12.5 15 15 .96 40 024 208/230-1-60 187 253 9.3 57 1.1 2.6 15.3 20 20 .96 40 030 208/230-1-60 187 253 13.6 67 1.1 2.6 20.7 30 30 .96 40 030 208/230-3-60 187 253 8.6 55 1.1 2


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21