York DH 180 user manual

User manual for the device York DH 180

Device: York DH 180
Category: Air Conditioner
Manufacturer: York
Size: 1.76 MB
Added : 6/10/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York DH 180. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York DH 180.

For your convenience

If looking through the York DH 180 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York DH 180 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York DH 180 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York DH 180 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York DH 180 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York DH 180. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

262260-YTG-E-1008
 
DESCRIPTION
YORK Sunline Ultra™ units are convertible single package
high efficiency rooftops. All models have independent dual
refrigerant circuits for efficient part load operation. Although
the units are primarily designed for curb mounting on a roof,
they can also be slab-mounted at ground level or set on steel
TECHNICAL GUIDE
beams above a finished roof.
All units include:
• Powder Paint finish that meets ASTM-B-117 1000 hour
salt spray standards
SINGLE PACKAGE G

Summary of the content on the page No. 2

262260-YTG-E-1008 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # Pg. # PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 10 SUPPLY AIR BLOWER PERFORMANCE (17.5 TON) - COOLING ONLY 210 MBH - BOTTOM DUCT FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . 5 11 SUPPLY AIR BLOWER PERFORMANC

Summary of the content on the page No. 3

262260-YTG-E-1008 PRODUCT NOMENCLATURE 15-25 Ton Sunline Ultra™ Model Number Nomenclature D H 180 N24 A 2 A AA 1 0 1 2 4 A Product Category Product Style D = A/C, Single Pkg., R-22 A = Style A Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. H = 10.0-11.0 EER A/C SS Drain Pan CPC Controller, DFS, APS Nominal Cooling Capacity Johnson Controller UNT 1126 (N2 protocol), DFS, APS Honeywell Con

Summary of the content on the page No. 4

262260-YTG-E-1008 • Low Ambient - An integrated low-ambient control FEATURES allows all units to operate in the cooling mode down to 0°F outdoor ambient without additional assis- All models are available with a wide variety of factory- tance. Optionally, the control board can be pro- mounted options such as stainless steel heat exchangers, grammed to lockout the compressors when the phase monitor, dirty filter switch, and coil guard to make them outdoor air temperature is low or when free c

Summary of the content on the page No. 5

262260-YTG-E-1008 ELECTRIC HEATER LOCATION (OPTIONAL ELECTRIC/ELECTRIC UNITS) HIGH EFFICIENCY COMPRESSORS WITH CRANKCASE HEATERS 20 GAUGE ALUMINIZED STEEL LONG LASTING COPPER TUBE/ALUMINUM FIN POWDER PAINT FINISH TUBULAR HEAT EXCHANGERS CONDENSER COILS ECONOMIZER HOOD LOW VOLTAGE RELAY BOARD AND TERMINAL STRIP ELECTRICAL DISCONNECT MOUNTING LOCATION (Field installed) KNOCKOUT FOR SIDE CONTROL WIRING ENTRY KNOCKOUT FOR 2" DISPOSABLE SIDE POWER WIRING ENTRY SIDE FILTERS TERMINAL BLOCK (For Single

Summary of the content on the page No. 6

262260-YTG-E-1008 available for single enthalpy and differential enthalpy Blower Motor Access compartment. The switch can be configurations, respectively). used to either route power to the VFD for modulating control of the blower motor, to bypass the drive and oper- The rainhood is painted to match the basic unit and must ate the motor at full speed, or to power the drive (and not be field-assembled before installing. the motor) for diagnostic purposes. • POWER EXHAUST - Our economizer opt

Summary of the content on the page No. 7

262260-YTG-E-1008 switch, an Outside Air Humidity sensor, a Return Air YORK COMMERCIAL COMFORT SYSTEM (YCCS) - Humidity sensor, an Inside IAQ sensor, and an Outside Provides rooftop system integration for YCCS single Air IAQ sensor. Construction mode operation, 365-day zone, change-over bypass and VAV systems. real time clock with 7 day programming plus holiday • SMOKE DETECTORS - (supply air & return air) The scheduling is built-in. Two different modes of demand smoke detectors stop opera

Summary of the content on the page No. 8

262260-YTG-E-1008 • HINGED/"TOOL FREE" BLOWER, BLOWER MOTOR, tudes up to 6,000 feet. This accessory supplements the FILTER AND ELECTRIC ACCESS PANELS - This basic propane conversion kit. option allows for complete hinged and tool free access to • SIDE DUCT FLANGES - One-inch flanges replace the the unit's blower, blower motor, filters and electrical panel supply and return air panels on the rear of the unit to sections. accommodate horizontal duct connections. These flanges can also be us

Summary of the content on the page No. 9

262260-YTG-E-1008 1 TABLE 1: INDOOR SOUND POWER RATING -12 SOUND POWER (db 10 Watts) ESP BLOWER UNIT Octave Band Centerline Frequency (Hz) dB(A) CFM SIZE SWL @ dB(A) IWG RPM BHP 63 125 250 500 1,000 2,000 4,000 8,000 2 10Ft. 180 6,000 1.00 1,080 4.60 99 99 89 82 84 77 72 67 89 56 210, 240 8,000 1.00 1,120 6.65 102 102 92 85 87 80 75 70 92 59 300 10,000 1.30 1,160 12.5 108 108 98 91 93 86 81 76 98 65 1. These values have been accessed using a model of sound propagation from a point source into th

Summary of the content on the page No. 10

262260-YTG-E-1008 TABLE 4: DH 180 COOLING CAPACITIES (15 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 75°F 85°F EVAPORATOR SENSIBLE CAPACITY, MBH SENSIBLE CAPACITY, MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 1 2 CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 90 85 80 75 70 65 90 85 80 75 70 65 °F 77 223.0 11.3 100.4 79.0 57.7 - - - 218.1 12.9 99.3 77.9 56.5 - - - 72 211.0 11.2 133.1 111.7 90.3 68.9 - - 203.0 12.6 130.5 109.2 87.8 66.4 - - 4500 67 199.0 11.1

Summary of the content on the page No. 11

262260-YTG-E-1008 TABLE 4: DH 180 COOLING CAPACITIES (15 TON) (CONTINUED) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 115°F EVAPORATOR SENSIBLE CAPACITY, MBH COIL TOTAL POWER ENTERING DRY BULB, °F 1 2 CAP. INPUT WB MBH KW CFM 90 85 80 75 70 65 °F 77 184.5 17.8 95.8 74.4 53.0 - - - 72 170.3 16.9 122.3 100.9 79.5 58.1 - - 4500 67 156.0 16.0 148.8 127.4 106.0 84.6 63.2 - 62 146.5 16.1 146.5 146.5 131.6 110.3 88.9 67.5 57 142.7 16.4 142.7 142.7 128.2 106.8 85.5 64.1 77 189.3 17.9 117.2 82.8 57.5 - -

Summary of the content on the page No. 12

262260-YTG-E-1008 TABLE 5: DH 210 COOLING CAPACITIES (17.5 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 75°F 85°F EVAPORATOR SENSIBLE CAPACITY, MBH SENSIBLE CAPACITY, MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 1 2 CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 90 85 80 75 70 65 90 85 80 75 70 65 °F 77 241.5 13.9 119.5 94.6 69.6 - - - 240.2 15.6 119.7 94.8 69.9 - - - 72 232.2 13.2 159.7 134.8 109.8 84.9 - - 226.1 15.1 156.3 131.4 106.4 81.5 - - 5250 67 223.0

Summary of the content on the page No. 13

262260-YTG-E-1008 TABLE 5: DH 210 COOLING CAPACITIES (17.5 TON) (CONTINUED) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 115°F 125°F EVAPORATOR SENSIBLE CAPACITY, MBH SENSIBLE CAPACITY, MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 1 2 CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 90 85 80 75 70 65 90 85 80 75 70 65 °F 77 217.8 12.5 112.3 87.3 62.4 - - - 207.3 10.1 108.4 83.5 58.5 - - - 72 199.9 12.2 143.0 118.0 93.1 68.1 - - 189.9 9.9 138.0 113.1 88.1 63.2 - - 525

Summary of the content on the page No. 14

262260-YTG-E-1008 TABLE 6: DH 240 COOLING CAPACITIES (20 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 75°F 85°F EVAPORATOR SENSIBLE CAPACITY, MBH SENSIBLE CAPACITY, MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 1 2 CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 90 85 80 75 70 65 90 85 80 75 70 65 °F 77 277.0 19.1 159.2 130.7 102.2 - - - 262.0 20.5 153.7 125.2 96.7 - - - 72 263.0 18.6 196.1 167.6 139.1 110.6 - - 249.0 20.1 190.4 161.8 133.3 104.8 - - 6000 67 249

Summary of the content on the page No. 15

262260-YTG-E-1008 TABLE 6: DH 240 COOLING CAPACITIES (20 TON) (CONTINUED) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 115°F EVAPORATOR SENSIBLE CAPACITY, MBH COIL TOTAL POWER ENTERING DRY BULB, °F 1 2 CAP. INPUT WB MBH KW CFM 90 85 80 75 70 65 °F 77 217.3 24.8 139.8 111.3 82.8 - - - 72 207.2 24.3 175.4 146.9 118.4 89.9 - - 6000 67 197.0 23.9 197.0 182.5 154.0 125.5 97.0 - 62 194.2 23.5 194.2 194.2 173.0 144.5 116.0 87.5 57 192.4 23.2 192.4 192.4 172.2 143.7 115.2 86.7 77 226.2 23.8 184.2 131.0 9

Summary of the content on the page No. 16

262260-YTG-E-1008 TABLE 7: DH 300 COOLING CAPACITIES (25 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 75°F 85°F EVAPORATOR SENSIBLE CAPACITY, MBH SENSIBLE CAPACITY, MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 1 2 CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 90 85 80 75 70 65 90 85 80 75 70 65 °F 77 371.3 19.7 191.8 156.2 120.6 - - - 348.9 21.5 185.5 149.8 114.2 - - - 72 334.4 19.3 233.0 197.4 161.8 126.1 - - 318.7 21.1 226.6 190.9 155.3 119.7 - - 7500 67 29

Summary of the content on the page No. 17

262260-YTG-E-1008 TABLE 7: DH 300 COOLING CAPACITIES (25 TON) (CONTINUED) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 115°F EVAPORATOR SENSIBLE CAPACITY, MBH COIL TOTAL POWER ENTERING DRY BULB, °F 1 2 CAP. INPUT WB MBH KW CFM 90 85 80 75 70 65 °F 77 302.0 29.3 147.5 111.8 76.2 - - - 72 274.5 28.5 198.2 162.6 126.9 91.3 - - 7500 67 247.1 27.7 247.1 213.3 177.7 142.0 106.4 - 62 242.9 27.1 242.9 242.9 220.0 184.3 148.7 113.1 57 238.3 27.2 238.3 238.3 208.0 172.3 136.7 101.1 77 306.2 29.3 187.3 123.

Summary of the content on the page No. 18

262260-YTG-E-1008 CFM, STATIC PRESSURE, AND POWER - ALTI- order to use the indoor blower tables for high altitude applica- tions, certain corrections are necessary. TUDE AND TEMPERATURE CORRECTIONS A centrifugal fan is a "constant volume" device. This means The information below should be used to assist in application that, if the rpm remains constant, the CFM delivered is the of product when being applied at altitudes at or exceeding same regardless of the density of the air. However, since

Summary of the content on the page No. 19

262260-YTG-E-1008 FIGURE 2 - ALTITUDE/TEMPERATURE CONVERSION FACTOR Johnson Controls Unitary Products 19

Summary of the content on the page No. 20

262260-YTG-E-1008 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE (15 TON) - COOLING ONLY 180 MBH - BOTTOM DUCT CONNECTIONS MOTOR CFM BLOWER PULLEY 4500 5250 6000 6750 7200 SPEED, (TURNS (RPM) ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW OPEN)* 208 VOLT AND STANDARD DRIVE 850 6.0** 0.9 2.4 2.2 0.7 3.0 2.7 0.5 3.2 2.9 - - - - - - 870 5.5 1.0 2.5 2.3 0.8 3.1 2.8 0.6 3.5 3.1 0.2 4.1 3.7 - - - 915 4.5 1.1 2.6 2.4 0.9 3.4 3.0 0.7 3.7 3.3 0.3 4.4 3.9 0.2 4.5 4.0 965 3.5 1.2 2.9 2.6 1.0 3.6 3.2 0.8 4


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21