Summary of the content on the page No. 1
036-21366-007-A-1205
DESCRIPTION
®
York Affinity™ Series packaged cooling/heating air condi-
tioners are designed for outdoor installation. Only utility and
TECHNICAL GUIDE
duct connections are required at the point of installation.
The gas-fired heaters have aluminized steel tubular heat
AFFINITY™ SERIES
exchangers and hot surface to pilot ignition. They are avail-
able in natural gas with field conversion to propane.
SINGLE PACKAGE GAS/ELECTRIC
FEATURING
AIR COOLED AIR CONDITIONERS
2 THR
Summary of the content on the page No. 2
036-21366-007-A-1205 TABLE OF CONTENTS 19 TYPICAL WIRING DIAGRAM D*NP 030-048 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 (460/575-3-60 POWER SUPPLY) . . . . . . . . . . . . . . . 30 STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . 4 20 TYPICAL WIRING DIAGRAM D*NP 060 (460/575-3-60 TYPICAL WIRING DIAGRAM NOTES . . . . . . . . . . 32 POWER SUPPLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MECHAN
Summary of the content on the page No. 3
036-21366-007-A-1205 will build-up. The condensate pan conforms to ASHRAE 62- STANDARD FEATURES/BENEFITS 89 standards (Ventilation for Acceptable Indoor Air Quality). OPERATING EFFICIENCY - All units provide high operating CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop- efficiencies and have a minimum AFUE of 80% and SEER of per connection is more durable over time. The connection is 13.0. All efficiencies exceed legislated minimum levels. rigidly mounted to assure proper fit and leak t
Summary of the content on the page No. 4
036-21366-007-A-1205 FAN SYSTEM - All 2-1/2, 3, 3-1/2 and 4 ton models operate LOW MAINTENANCE - Long life, permanently lubricated over a wide range of design conditions with a constant CFM, condenser and evaporator fan motor bearings need no electrically commutated (ECM) fan motor. These units easily annual maintenance adding greater reliability to the unit. match all types of applications and provide greater on site Blower assembly can be easily cleaned by the unique Slip- flexibility to
Summary of the content on the page No. 5
036-21366-007-A-1205 enthalpy to determine the most economical mix. Single 50% of outdoor air (field supplied). Closes on power loss, Enthalpy sensor also required. includes hood and screen assembly. PRESSURE SWITCH UPGRADE KIT - Contains screw in RECTANGLE TO ROUND ADAPTERS - Kit includes one type High pressure, Low Pressure/Loss of Charge switch, supply and one return air rectangle to round duct adapter. freeze protection switch and lockout relay. Switches are Adapters are preformed and de
Summary of the content on the page No. 6
036-21366-007-A-1205 DIRECT DRIVE CONDENSER FAN MOTOR BLOW-THROUGH DESIGN WITH RELIABLE ALUMINIZED STEEL TUBULAR HEAT EX HANGERS C HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN EVAPORATOR COIL HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN CONDENSER COIL LONG LASTING POWDER PAINT FINISH DECORATIVE PROTECTIVE COIL GAURD REAR AND BOTTOM HIGH EFFICIENCY RETUN R AIR COMPRESSOR AND SUPPLY AIR RIGIDLY DUCT OPENINGS MOUNTED HOT SURFACE PILOT ASSEMBLY HIGH GRADE ALUMINIZED HEAVY GAUGE IN-SHOT
Summary of the content on the page No. 7
036-21366-007-A-1205 TABLE 2: RATINGS COOLING/GAS HEATING 1 GAS HEAT CAPACITY / EFFICIENCIES NET COOLING CAPACITY SOUND MODEL TEMP. RATING 5 INPUT OUTPUT NUMBER OF AFUE DNP 3 4 MBH SEER EER 2 RISE (dbels) (MBH) (MBH) (%) BURNERS (°F) RANGE 024N03606 25.4 13.3 11.6 81 45 36 80.2 2 25 - 55 024N05606 25.4 13.3 11.6 81 70 56 80.2 3 30 - 60 030N03606 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55 030N03625 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55 030N03646 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55 030N05606 30
Summary of the content on the page No. 8
036-21366-007-A-1205 TABLE 3: DNP024 COOLING CAPACITIES - 2 TON TEMPERATURE OF AIR ON CONDENSER COIL TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 SENSIBLE CAPACITY SENSIBLE CAPACITY COIL NET POWER NET POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F CAP. INPUT CAP. INPUT WB MBH KW MBH KW CFM 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F 72 24.7 1.90 15.0 13.3 11.6 9.9 8.1 #N/A #N/A 23.1 2.03 15.0 13.3 11.6 9.9 8.1 #N/A #N/A 67 22.6 1.91 18.4 16.7 14.9 13.2 11.5 9.8 8.1 2
Summary of the content on the page No. 9
036-21366-007-A-1205 TABLE 3: DNP024 COOLING CAPACITIES - 2 TON (CONT’D) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 125°F EVAPORATOR 1 SENSIBLE CAPACITY COIL NET POWER ENTERING DRY BULB, °F CAP. INPUT WB MBH KW CFM 86 83 80 77 74 71 68 °F 72 18.4 2.5 13.1 11.4 9.7 8.0 6.3 #N/A #N/A 67 16.6 2.4 16.7 15.0 13.3 11.5 9.8 8.1 6.4 600 62 16.2 2.5 16.2 16.2 14.8 13.1 11.4 9.6 7.9 57 16.5 2.5 16.5 16.5 14.9 13.2 11.5 9.8 8.1 72 19.3 2.6 14.6 12.5 10.5 8.5 6.5 #N/A #N/A 67 17.4 2.5 17.8 16.4 14.4
Summary of the content on the page No. 10
036-21366-007-A-1205 TABLE 4: DNP030 COOLING CAPACITIES - 2-1/2 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,000 CFM 1,250 CFM OF AIR ON WB °F WB °F CONDENSER COIL 72 67 62 57 72 67 62 57 NET CAP.MBH 33.6 31.6 30.3 30.2 34.5 32.4 31.1 31.0 TOTAL POWER INPUT kW 2.4 2.4 2.3 2.3 2.6 2.6 2.5 2.5 86 23.6 29.2 30.3 30.2 27.2 32.4 31.1 31.0 83 20.7 26.3 30.3 30.2 23.5 29.7 31.1 31.0 85 °F 80 17.8 23.4 28.4 29.6 19.7 25.9 31.1 31.0 77 14.9 20.5 25.5 26.7 16.0 22.2 27.3 27.3 74 12.0 17.5 22.6 23.8 12.3 18
Summary of the content on the page No. 11
036-21366-007-A-1205 TABLE 5: DNP036 COOLING CAPACITIES - 3 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,200 CFM 1,350 CFM OF AIR ON WB °F WB °F CONDENSER COIL 72 67 62 57 72 67 62 57 NET CAP. 43.3 39.9 37.4 36.7 44 40.5 38 37.2 MBH TOTAL POWER 2.93 2.89 2.9 2.883.083.053.063.04 INPUT kW 86 29.5 35.8 37.4 36.7 31.8 38.4 38 37.2 83 26 32.3 37.4 36.7 27.8 34.4 38 37.2 85 °F 80 22.5 28.8 34.8 35.6 23.8 30.4 36.7 36.7 77 19 25.3 31.3 32.1 19.9 26.4 32.7 32.7 74 15.5 21.8 27.8 28.6 15.9 22.5 28.7 28.7
Summary of the content on the page No. 12
036-21366-007-A-1205 TABLE 6: DNP042 COOLING CAPACITIES - 3-1/2 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,350 CFM 1,500 CFM OF AIR ON WB °F WB °F CONDENSER COIL 72 67 62 57 72 67 62 57 NET CAP. 48.4 44.5 40.9 41.2 54.0 49.6 45.6 46.0 TOTAL POWER 3.4 3.3 3.3 3.3 3.8 3.7 3.6 3.7 86 33.0 39.9 40.9 41.2 36.8 44.4 45.6 46.0 83 29.1 36.0 40.9 41.2 32.4 40.1 45.6 46.0 85 °F 80 25.2 32.0 38.1 40.4 28.1 35.7 42.4 45.0 77 21.3 28.1 34.2 36.5 23.7 31.3 38.1 40.7 74 17.3 24.2 30.2 32.6 19.3 27.0 33.7 36.3
Summary of the content on the page No. 13
036-21366-007-A-1205 TABLE 7: DNP048 COOLING CAPACITIES - 4 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,400 CFM 1,600 CFM OF AIR ON WB °F WB °F CONDENSER COIL 72 67 62 57 72 67 62 57 NET CAP. 54.0 49.2 45.6 45.9 55.2 50.4 46.6 46.9 MBH TOTAL POWER 3.69 3.66 3.62 3.57 3.85 3.83 3.79 3.73 INPUT kW 86 35.8 43.7 45.6 45.9 39.1 47.7 46.6 46.9 83 31.7 39.6 44.6 45.3 34.5 43 46.6 46.9 85 °F 80 27.7 35.6 42.4 43.6 29.8 38.3 45.7 46.9 77 23.6 31.6 38.4 39.5 25.1 33.7 41 42.3 74 19.6 27.5 34.3 35.5 20.5 29 3
Summary of the content on the page No. 14
036-21366-007-A-1205 TABLE 8: DNP060 COOLING CAPACITIES - 5 TON AIR ON EVAPORATOR COIL TEMPERATURE 1,500 CFM 1,800 CFM OF AIR ON WB °F WB °F CONDENSER COIL 72 67 62 57 72 67 62 57 NET CAP. 63.5 57.6 52.7 53.1 64.3 58.3 53.3 53.7 MBH TOTAL POWER 4.49 4.44 4.38 4.27 4.68 4.63 4.57 4.45 INPUT kW 86 39.4 47.5 52.7 53.1 41.4 49.6 53.3 53.7 83 35.0 43.2 50.9 53.1 36.1 44.3 52.0 53.7 85 °F 80 30.6 38.8 46.5 50.5 30.7 38.9 46.6 50.7 77 26.3 34.4 42.1 46.2 25.4 33.5 41.2 45.3 74 21.9 30.0 37.7 41.8 20.0
Summary of the content on the page No. 15
036-21366-007-A-1205 1 TABLE 9: TWO TON AIR PERFORMANCE EXTERNAL STAIC PRESSURE - IWG MODEL # .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 DNP MTR (Cooling/ SPD Heating) SIDE SUPPLY AIR PERFORMANCE - 208 VOLT HI -- ----- --- 984443894422751390608358---- 024 MED 994 333 947 321 901 309 854 297 774 280 695 263 615 246 - - - - - - - - LOW743243700235657226614218 ---- ----- - ---- SIDE SUPPLY AIR BLOWER PERFORMANCE - 230 VOLT HI -- ----- ----- 929491809473688454---- 024 MED - - - - 999 353 944 338
Summary of the content on the page No. 16
036-21366-007-A-1205 1 TABLE 10: SIDE SUPPLY AIR BLOWER PERFORMANCE - 208/230 VOLTS EXTERNAL STATIC PRESSURE - IWG MODEL # MODE CFM .20 .30 .40 .50 .60 .70 .80 .90 1.0 DNP (COOLING / HEATING) WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS COOLING 030 1000 248 298 325 365 385 411 470 498 500 (FACTORY SETTING) COOLING 030 1250 342 385 431 474 510 562 614 657 694 (FIELD SETTING) HEATING (2 TUBE) 030 850 169 217 237 278 302 334 374 401 431 (FACTORY SETTING) HEATING (3 TUBE) 030 1100
Summary of the content on the page No. 17
036-21366-007-A-1205 1 TABLE 11: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 208/230 VOLTS EXTERNAL STATIC PRESSURE - IWG MODEL # MODE CFM .20 .30 .40 .50 .60 .70 .80 .90 1.0 DNP (COOLING / HEATING) WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS COOLING 030 1000 248 298 325 365 385 411 470 498 500 (FACTORY SETTING) COOLING 030 1250 342 385 431 474 510 562 614 657 694 (FIELD SETTING) HEATING (2 TUBE) 030 850 169 217 237 278 302 334 374 401 43
Summary of the content on the page No. 18
036-21366-007-A-1205 TABLE 12: ADDITIONAL STATIC PRESSURE RESISTANCE - 2, 2-1/2, 3 TON RESISTANCE, IWG DESCRIPTION CFM 500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 WET EVAPORATOR COIL .01 .01 .01 .02 .03 .04 .05 .06 .07 .08 .09 .09 1 .00 .00 .00 .01 .01 .01 .01 .02 .03 .04 .05 .06 ECONOMIZER FILTER FRAME KIT .01 .02 .04 .06 .08 .10 .13 .16 .17 .18 .19 .20 1. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the r
Summary of the content on the page No. 19
036-21366-007-A-1205
FIGURE 4 - POWER
Summary of the content on the page No. 20
036-21366-007-A-1205 V E N T A I R O U T L E T H O O D B L O W E R S E R V I C E C O N D E N S E R C O I L A C C E S S C O M P A R T M E N T P A N E L G A S S U P P L Y 1 - 1 / 4 " D I A . H O L E ( 1 / 2 " N P T I C O N N E C T I O N ) U N I T C O N D E N S A T E A C O N N E C T I O N 3 / 4 " N P T I ( T R A P R E