VXI VM4016 user manual

User manual for the device VXI VM4016

Device: VXI VM4016
Category: Computer Hardware
Manufacturer: VXI
Size: 0.61 MB
Added : 9/5/2013
Number of pages: 93
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for VXI VM4016. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with VXI VM4016.

For your convenience

If looking through the VXI VM4016 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual VXI VM4016 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual VXI VM4016 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
VXI VM4016 User manual - Online PDF
Advertisement
« Page 1 of 93 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual VXI VM4016 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to VXI VM4016. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1







VM4016

ANALOG COMPARATOR


USER’S
MANUAL


82-0022-000
Rev. December 1, 2003



VXI Technology, Inc.

2031 Main Street
Irvine, CA 92614-6509
(949) 955-1894



bus

Summary of the content on the page No. 2

2

Summary of the content on the page No. 3

www.vxitech.com TABLE OF CONTENTS INTRODUCTION Certification ..........................................................................................................................................................5 Warranty ...............................................................................................................................................................5 Limitation of Warranty ...................................................................................

Summary of the content on the page No. 4

VXI Technology, Inc. Common SCPI Commands ....................................................................................................................................52 *CLS ...................................................................................................................................................................52 *ESE ................................................................................................................................................

Summary of the content on the page No. 5

www.vxitech.com CERTIFICATION VXI Technology, Inc. (VTI) certifies that this product met its published specifications at the time of shipment from the factory. VTI further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration facilities of other International Standards Organization members

Summary of the content on the page No. 6

VXI Technology, Inc. DECLARATION OF CONFORMITY Declaration of Conformity According to ISO/IEC Guide 22 and EN 45014 MANUFACTURER’S NAME VXI Technology, Inc. MANUFACTURER’S ADDRESS 2031 Main Street Irvine, California 92614-6509 PRODUCT NAME Analog Comparator MODEL NUMBER(S) VM4016 PRODUCT OPTIONS All PRODUCT CONFIGURATIONS All VXI Technology, Inc. declares that the aforementioned product conforms to the requirements of the Low Voltage Directive 73/23/EEC and the EMC Di

Summary of the content on the page No. 7

www.vxitech.com GENERAL SAFETY INSTRUCTIONS Review the following safety precautions to avoid bodily injury and/or damage to the product. These precautions must be observed during all phases of operation or service of this product. Failure to comply with these precautions, or with specific warnings elsewhere in this manual, violates safety standards of design, manufacture, and intended use of the product. Service should only be performed by qualified personnel. TERMS AND SYMBOLS

Summary of the content on the page No. 8

VXI Technology, Inc. WARNINGS (CONT.) Avoid Electric Shock To avoid electric shock or fire hazard, do not operate this product with the covers removed. Do not connect or disconnect any cable, probes, test leads, etc. while they are connected to a voltage source. Remove all power and unplug unit before performing any service. Service should only be performed by qualified personnel. Ground the Product This product is grounded through the grounding conductor of the power cord. T

Summary of the content on the page No. 9

www.vxitech.com SUPPORT RESOURCES Support resources for this product are available on the Internet and at VXI Technology customer support centers. VXI Technology World Headquarters VXI Technology, Inc. 2031 Main Street Irvine, CA 92614-6509 Phone: (949) 955-1894 Fax: (949) 955-3041 VXI Technology Cleveland Instrument Division VXI Technology, Inc. 7525 Granger Road, Unit 7 Valley View, OH 44125 Phone: (216) 447-8950 Fax: (216) 447-8951 VXI Technology Lake St

Summary of the content on the page No. 10

VXI Technology, Inc. 10 VM4016 Preface

Summary of the content on the page No. 11

www.vxitech.com SECTION 1 INTRODUCTION INTRODUCTION The VM4016 is a high-performance Analog Comparator module which has been designed to monitor analog signals and cause VXIbus interrupts to occur when programmed input limits have been exceeded. The instrument uses the message-based word serial interface for programming and data movement, as well as supporting direct register access for very high-speed data retrieval. The VM4016 command set conforms with the SCPI standard for consis

Summary of the content on the page No. 12

VXI Technology, Inc. Regardless of whether the VM4016 is configured with other VM4016 modules or with other VMIPmodules, each group of 16 channels is treated as an independent instrument in the VXIbus chassis and, as such, each group has its own FAIL and ACCESS light. The FAIL LED is a Power/Fault indicator. When normal power up conditions exist, the FAIL LED will illuminate green. When a power on fault condition occurs, the FAIL FAIL ACC/ LED will illuminate red. The ACC/ERR LED

Summary of the content on the page No. 13

www.vxitech.com VXI MODULE PANEL TO VXIBUS CHANNEL 1 OF COMPARE REGISTERS CH1+ DIFFERENTIAL AMPLIFIER DEBOUNCE CH1- X1 OR X0.1 COMPARATOR 10 uS TO 0.5 S 8 BIT DAC INVERT MASK REGISTER REGISTER INTERRUPT VXIbus AND FIRST INTERRUPT LIMIT LOGIC +5V CHANNEL 16 OF FIRST LIMIT INVERT REGISTER IRQ FIRST LIMIT TO VXIBUS LATCH FIRST LIMIT INTERRUPT REGISTER REGISTER INVERT REGISTER +5V L IRQ FIGURE 1-3: VM4016 BLOCK DIAGRAM VM4016 Preparation for Use 13

Summary of the content on the page No. 14

VXI Technology, Inc. VM4016 GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS CHANNELS 16 VM4016-1 VM4016-2 32 VM4016-3 48 INPUT RANGE ±10.0 V, ±100 V INPUT THRESHOLD ±10.0 V 78 mV ±100.0 V 780 mV INPUT TYPE Differential, may be configured for single-ended by grounding the negative input INPUT IMPEDANCE 200 k Ω Differential 100 k Ω Single-ended INPUT POLARITY Rising or Falling Edge DEBOUNCE TIME 9.6 µs to 0.6291456 s, 9.6 µs resolution IRQ OUTPUT Open Col

Summary of the content on the page No. 15

www.vxitech.com Section 2 SECTION 2 PREPARATION FOR USE INSTALLATION When the VM4016 is unpacked from its shipping carton, the contents should include the following items: One VM4016 VXIbus module One VM4016 Analog Comparator Module User’s Manual (this manual) All components should be immediately inspected for damage upon receipt of the unit. Once the VM4016 is assessed to be in good condition, it may be installed into an appropriate C-size or D-size VXIbus chassis in any s

Summary of the content on the page No. 16

VXI Technology, Inc. SETTING THE CHASSIS BACKPLANE JUMPERS Please refer to the chassis User’s Manual for further details on setting the backplane jumpers. SETTING THE LOGICAL ADDRESS The logical address of the VM4016 is set by a single 8-position DIP switch located near the module’s backplane connectors (this is the only switch on the module). The switch is labeled with positions 1 through 8 and with an ON position. A switch pushed toward the ON legend will signify a logic 1; switch

Summary of the content on the page No. 17

www.vxitech.com The connector used in the VM4016 is a commonly available 44-pin high density DSUB receptacle connector. A mating solder cup pin connector from AMP is included, crimp type connectors are available from a variety of sources. TABLE 2-1: ANALOG COMPARATOR PIN OUTS SIGNAL PIN NUMBER SIGNAL PIN NUMBER CHANNEL 1 + 1 GROUND 23 CHANNEL 1 - 2 CHANNEL 11 + 24 GROUND 3 CHANNEL 11 - 25 CHANNEL 4 + 4 CHANNEL 14 + 26 CHANNEL 4 - 5 CHANNEL 14 - 27 CHANNEL 7 + 6 GROUND 28 CHA

Summary of the content on the page No. 18

VXI Technology, Inc. The mating connector to J200, J201 or J202 is available from the following company: Assmann Electronic, Inc. P/N AHDS44LL-T Mating Connector The pin locations for J200, J201 and J202 are shown in Figure 2-2. 16 31 1 44 15 30 FIGURE 2-2: J200, J201 AND J202 PIN LOCATIONS 18 VM4016 Preparation for Use

Summary of the content on the page No. 19

www.vxitech.com SECTION 3 PROGRAMMING EXAMPLES OF SCPI COMMANDS FETCH:CONDITIONED? The FETCh:CONDition query returns the 16-bit value that represents the current conditioned (masked and inverted) state of the inputs. It is important to note that this information is also available at the VXIbus register level at offset 0x28. FETCh:CONDitioned? No query parameters. EXAMPLES FETCh:CONDitioned? Returns the state of the conditioned 0 (masked and inverted) inputs. VM4016

Summary of the content on the page No. 20

VXI Technology, Inc. FETCH:LATCHED? The FETCh:LATChed query returns a 16-bit value that reports the active signals in the First Latched register. The First Latched register records the active signals when the first new input channel crossed its threshold. It is important to note that the above information is also available at the VXIbus register level at offset 0x30. FETch:LATChed? No query parameters EXAMPLES FETCh:LATChed? Returns the active signals in the First 1 Latche


Alternative user manuals
# User manual Category Download
1 VXI VX1410A User manual Computer Hardware 0
2 VXI ITONA TC4XYY User manual Computer Hardware 3
3 VXI VX1420A User manual Computer Hardware 1
4 Sony MSAKIT-PC4A User manual Computer Hardware 2
5 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
6 Philips MATCH LINE 9596 User manual Computer Hardware 17
7 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
8 Philips PSC702 User manual Computer Hardware 1
9 Sony MRW62E/S1/181 User manual Computer Hardware 3
10 Sony 64GB SDHC Class 10 Memory Card Readers SF32N4/TQM User manual Computer Hardware 1
11 Philips SAA7345 User manual Computer Hardware 1
12 Philips SBC MC8650 User manual Computer Hardware 268
13 Philips PSC 605 User manual Computer Hardware 1
14 Sony DKA-MC2F User manual Computer Hardware 1
15 Sony AR-B1570 User manual Computer Hardware 2