York 12 SEER H*RC018 THRU 060 user manual

User manual for the device York 12 SEER H*RC018 THRU 060

Device: York 12 SEER H*RC018 THRU 060
Category: Air Conditioner
Manufacturer: York
Size: 0.3 MB
Added : 6/10/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York 12 SEER H*RC018 THRU 060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York 12 SEER H*RC018 THRU 060.

For your convenience

If looking through the York 12 SEER H*RC018 THRU 060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York 12 SEER H*RC018 THRU 060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York 12 SEER H*RC018 THRU 060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York 12 SEER H*RC018 THRU 060 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York 12 SEER H*RC018 THRU 060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York 12 SEER H*RC018 THRU 060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

G
H
I N
T
G
N
WI
Y
T
L
I
P
D
CE
OM
ON
S C
C
RT
-
I
R
F
I A
E
A R I
I
R
I
Q
CA
A
A
T
U
S T
I
O
I
A
O
036-21137-004 Rev. C (0505)
DESCRIPTION
The 12 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, each designed to serve a specific function. Match-
ing Air Handlers are available for upflow, downflow or hori-
zontal applications to provide a complete system. Electr

Summary of the content on the page No. 2

036-21137-004 Rev. C (0505) Physical and Electrical Data - 1 Phase MODEL H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Supply Voltage 208/230 – 1 – 60 Normal Voltage Range 187 to 252 1 10.1 14.1 16.5 19.7 26.2 28.5 37.5 Minimum Circuit Ampacity 2 15 25 25 30 45 50 60 Max. Overcurrent Device Amps 3 B B Recip Inertia Recip Recip Recip Compressor Type Scroll Scroll Rated Load 7.7 10.9 12.8 14.7 19.9 21.8 28.8 Compressor Amps Locked Ro

Summary of the content on the page No. 3

036-21137-004 Rev. C (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 1 53 59 63 73 78 87 – Unit Orifice (s) Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5 - 8 5 - 3 6 - 13 7 - 7 8 - 15 5 4 2 3 Indoor Coil Coil Orifice Orifice or TXV Kit - Additional Charge, Oz. 53 + 3 59 + 3 – – – – – G2FD024(S,H)14,17 61 701 + 3 701 + 3 – – – – – 53 + 6 59 + 6 63 + 4 – – – – G2FD030(S,H)17 6

Summary of the content on the page No. 4

036-21137-004 Rev. C (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems (Continued)- 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 1 53 59 63 73 78 87 – Unit Orifice (s) Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5 - 8 5 - 3 6 - 13 7 - 7 8 - 15 5 4 2 3 Indoor Coil Coil Orifice Orifice or TXV Kit - Additional Charge, Oz. – – 63 + 15 73 + 12 – – – G1NA036S17L 63 – – 701 + 15 702 + 12 – – – – – – 73

Summary of the content on the page No. 5

036-21137-004 Rev. C (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit H1RC036S H1RC048S H1RC060S 1 –– – Unit Orifice (s) Factory R-22 Charge, lbs-oz 6 - 2 7 - 10 9 - 3 2 3 Indoor Coil Coil Orifice TVX Kit = Additional Charge, Oz G2FD035(S,H)14 65 702 + 0 – – G2FD036(S,H)17,21 75 702 + 3 – – G2FD042(S,H)21 78 702 + 0 – – G2FD046(S,H)17 78 702 + 9 703 + 0 – G2FD048(S,H)21,24 84 702 + 17 703 + 9 – G2FD060(S,H)24 90 – 703 + 0 703 + 20 G2FD061H24 90 –

Summary of the content on the page No. 6

036-21137-004 Rev. C (0505) COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING 1 COIL 2 UNIT MODEL NET MBH SEER RATED SEER ELECTRIC MODEL W MODEL EER 3 CFM W/O TXV HEAT KW TOTAL SENS. WITH TXV 1 PH 12 SEER AC WITH N1AH / G2FD H2RC018S06 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 600 19.6 13.2 12.50 12.50 11.60 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 750 23.6 16.9 12.00 12.00 11.00 H2RC024S06 N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 750 24.0 17.3 12.00 12.00 11.10 N1AHB1

Summary of the content on the page No. 7

036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL UNIT MODEL NET MBH CFM RANGE SEER MODEL 1 WRATED CFM EER SEER + TXV (Min.-max.) W/O TXV TOTAL SENS. 14,17 G1FA024S14,17 600 19.2 13.0 12.00* 12.00 11.35 14 G1HA024H14 600 19.2 13.6 12.00* – 11.50 14 G1HA024H14T 600 19.2 13.6 – 12.00* 11.60 - G1HD024 600 20.0 13.5 12.50* 12.50 11.70 17 G1NA030S17K 600 20.0 13.5 12.75* 12.75 11.75 525 H2RC018S06 21 G1NA030S21M 600 20.0 13.5 12.50*

Summary of the content on the page No. 8

036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH CFM RANGE SEER MODEL 1 WRATED CFM EER SEER + TXV (Min.-max.) W/O TXV TOTAL SENS. 14 G1FA036S14 1200 33.6 23.4 11.50* 11.50 10.60 17,21 G1FA036S17,21 1200 33.0 23.0 11.25* 11.25 10.45 17 G1FA048S17 1200 35.0 24.4 12.00* 12.00 10.90 21 G1FA048S21 1200 34.0 25.2 12.00* 12.00 10.70 14 G1HA036H14 1150 33.5 23.8 12.00* – 10.75

Summary of the content on the page No. 9

036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH CFM RANGE SEER MODEL 1 WRATED CFM EER SEER + TXV (Min.-max.) W/O TXV TOTAL SENS. 17 G1FA048S17 1575 45.5 34.1 12.00* 12.00 11.00 21 G1FA048S21 1575 46.5 34.9 12.00* 12.00 11.00 21,24 G1FA060S21,24 1575 48.0 36.0 12.50* 12.50 11.10 21 G1HA048H21 1550 46.0 33.6 12.00* – 11.10 21 G1HA048H21T 1525 46.0 33.6 – 12.00* 11.11 24 G1HA060H24 1575 47.0 33.8 1

Summary of the content on the page No. 10

036-21137-004 Rev. C (0505) COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED 1 UNIT MODEL W NET MBH SEER COIL MODEL RATED SEER FURNACE MODEL EER 2 CFM W/O TXV + TXV TOTAL SENS. 3 1 PH 12 SEER AC - VARIABLE SPEED P1DUA12V/PV8A12****UH G1FA024S14 14 600 19.6 13.4 – 13.00 12.55 P1DUA12V/PV8A12****UH G2FD024(S,H)14 14 600 20.0 13.6 – 14.00 12.90 H2RC018S06 P1XDB12V G2FD024(S,H)17 17 620 20.2 14.0 – 13.75 12.90 P1XUB12V G1FA024S17 17 620 19.6 13.4 – 1

Summary of the content on the page No. 11

036-21137-004 Rev. C (0505) COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED 1 UNIT MODEL W NET MBH SEER COIL MODEL RATED SEER FURNACE MODEL EER 2 CFM W/O TXV + TXV TOTAL SENS. P1DUC20V/PV8C20****UH G1FA048S21 21 1610 46.5 34.9 – 12.10 11.15 P1DUC20V/PV8C20****UH G2FD048(S,H)21 21 1610 46.5 34.9 – 12.25 11.05 P1XDD20V G2FD048(S,H)24 24 1610 47.0 35.4 – 12.40 11.00 P1XUC16V G1FA048S21 21 1480 46.0 34.4 – 12.10 10.90 P1XUC16V G2FD048(S,H)21 21 1480 46.0 34.4 – 12.30 10.80 H2R

Summary of the content on the page No. 12

036-21137-004 Rev. C (0505) ACCESSORIES* Refer to Price Manual for specific model numbers. C Hard Start Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the nor- A mal compressor operating sound. Refer to price pages for specific match-ups. Off Cycle Timer Delay - Provides a 5-minute off cycle to pre- vent rapid recycling of the compressor. Room Thermostats - A wide selection of compatible thermo- B s

Summary of the content on the page No. 13

036-21137-004 Rev. C (0505) TYPICAL INSTALLATION MINIMUM 18” SERVICE ACCESS THERMOSTAT TO FURNACE OR CLEARANCE ON ONE SIDE 60” OVERHEAD AIR HANDLER CLEARANCE WEATHERPROOF TERMINAL BLOCK DISCONNECT SWITCH NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10” CLEARANCE TO INDOOR COIL COILAREA SEAL OPENING(S) WITH NOTE: ALL OUTDOOR WIRING PERMAGUM OR EQUIVALENT MUST BE WEATHERPROOF. CONTROLACCESS PANEL TYPICAL FIELD WIRING - 1 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND

Summary of the content on the page No. 14

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC018S06 INDOOR COIL MODEL NO. G1FA024S14,17 IDCFM 500 650 800 CONDENSING| ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 20.1 19.3 18.2 20.1 19.4 18.6 20.1 19.5 18.9 75 S.C. 11.7 11.5 11.3 12.112.212.212.512.813.1 KW 1.26 1.25 1.25 1.27 1.26 1.26 1.27 1.26 1.26 T.C. 19.8 18.7 17.0 20.0 19.1 17.7 20.3 19.5 18.3 85 S.C. 11.7 11.4 1

Summary of the content on the page No. 15

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC024S06 INDOOR COIL MODEL NO. G1FA036S17,21 IDCFM 600 800 1000 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 25.4 24.2 22.5 25.6 24.5 23.2 25.8 24.9 23.9 75 S.C. 14.6 14.6 13.8 15.4 15.6 15.4 16.3 16.6 17.1 KW 1.61 1.60 1.59 1.61 1.60 1.59 1.62 1.61 1.60 T.C. 24.9 23.6 21.4 25.1 23.9 22.2 25.3 24.2 23.0 85 S.C. 14.8 14.7 13.8 15.9 16.1 15.6 17.0

Summary of the content on the page No. 16

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC030S06 INDOOR COIL MODEL NO. G1FA036S17,21 IDCFM 800 1000 1200 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 31.9 30.6 28.9 27.4 30.9 29.4 23.0 31.2 29.9 75 S.C. 18.9 19.1 18.9 19.7 20.1 20.3 20.5 21.2 21.8 KW 1.97 1.95 1.94 1.98 1.96 1.95 1.98 1.97 1.95 T.C. 31.4 29.3 27.0 28.2 30.1 28.9 25.0 30.6 30.9 85 S.C. 19.2

Summary of the content on the page No. 17

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC036S06 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 36.7 34.3 32.3 36.9 34.9 32.8 37.2 35.4 33.2 75 S.C. 23.2 22.8 22.5 24.3 24.2 23.9 25.4 25.6 25.4 KW 2.31 2.30 2.27 2.33 2.30 2.28 2.34 2.31 2.30 T.C. 35.3 33.1 30.9 35.7 33.7 31.4 36.2 34.2 31.9 85 S.C. 23.2 22.6 21.9 24.8 24.3 23.6 26.3

Summary of the content on the page No. 18

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RC036S(25,46) INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 39.7 37.5 36.7 39.0 37.7 36.8 39.0 37.6 36.8 75 S.C. 23.9 23.8 25.0 23.5 24.3 25.3 24.0 25.1 25.6 KW 2.97 2.94 2.91 2.97 2.95 2.91 2.96 2.94 2.92 T.C. 38.3 36.1 34.4 37.9 36.3 34.6 38.0 36.4 34.9 85 S.C. 24

Summary of the content on the page No. 19

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC042S06 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 46.4 45.7 43.0 46.4 45.9 43.3 46.5 46.0 43.5 75 S.C. 27.0 27.5 27.8 27.9 29.0 29.5 28.8 30.5 31.2 KW 2.45 2.44 2.45 2.47 2.45 2.46 2.48 2.45 2.46 T.C. 45.5 44.1 41.1 45.6 44.4 41.6 45.7 44.7 42.0 85 S.C. 27.5 27.5 27.2 28.6 29.2 29.1 29.7

Summary of the content on the page No. 20

036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RC048S06 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1375 1575 1775 CONDENSING ENTERING AIR ID DB (°F) 85 80 75 85 80 75 85 80 75 TEMPERATURE ID WB (°F) 72 67 63 72 67 63 72 67 63 T.C. 52.8 49.9 45.4 53.5 50.6 46.8 54.2 51.3 48.2 75 S.C. 33.3 32.7 31.5 34.9 34.5 33.6 36.5 36.2 35.7 KW 3.14 3.09 3.03 3.15 3.10 3.04 3.17 3.12 3.06 T.C. 50.9 47.1 42.4 51.6 48.1 43.5 52.3 49.1 44.7 85 S.C. 33.3 32


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 14 Series User manual Air Conditioner 120
6 York 13 Series User manual Air Conditioner 67
7 York 13 User manual Air Conditioner 63
8 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
9 York 10 SEER 50HZ R22 User manual Air Conditioner 83
10 York 14 User manual Air Conditioner 44
11 York 14.5 SEER TCGF60 User manual Air Conditioner 25
12 York 14.5 SEER TCGF24 User manual Air Conditioner 29
13 York 251934-YTG-J-0910 User manual Air Conditioner 32
14 York 36 User manual Air Conditioner 78
15 York AFFINITY 291627-YTG-B-0807 User manual Air Conditioner 27
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21