Summary of the content on the page No. 1
REJ10J1396-0300
H8SX/1582 PLQP0120LA-A
User System Interface Cable
HS1582ECH61H User’s Manual
Renesas Microcomputer Development Environment System
H8SX Family / H8SX/1500 Series
HS1582ECH61HE
Rev.3.00
Revision Date: Sep. 08, 2008
Summary of the content on the page No. 2
Rev. 3.00 Sep. 08, 2008 Page ii of vi REJ10J1396-0300
Summary of the content on the page No. 3
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this do
Summary of the content on the page No. 4
Rev. 3.00 Sep. 08, 2008 Page iv of vi REJ10J1396-0300
Summary of the content on the page No. 5
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interfac
Summary of the content on the page No. 6
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy
Summary of the content on the page No. 7
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper
Summary of the content on the page No. 8
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an immi
Summary of the content on the page No. 9
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000H emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always befor
Summary of the content on the page No. 10
Rev. 3.00 Sep. 08, 2008 Page VI of VI REJ10J1396-0300
Summary of the content on the page No. 11
Preface The HS1582ECH61H is a user system interface cable that connects an H8SX/1582 E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an PLQP0120LA-A (former package: FP-120B) package for the H8SX/1582 MCU on the user system.
Summary of the content on the page No. 12
Contents Section 1 Configuration...........................................................................................1 Section 2 Connection Procedures............................................................................3 2.1 Connecting User System Interface Cable to Emulator Station ............................................. 3 2.2 Connecting User System Interface Cable to User System .................................................... 5 2.2.1 Installing IC Socket...........
Summary of the content on the page No. 13
Section 1 Configuration Section 1 Configuration CAUTION Use an NQPACK120SE-ND socket and an HQPACK120SE cover (manufactured by Tokyo Eletech Corporation) for the PLQP0120LA-A package IC socket on the user system. Figure 1 and table 1 show the external appearance and components, respectively, of the HS1582ECH61H user system interface cable for the PLQP0120LA-A package. To emulator station Cable body Screws (M2.0 x 10 mm) Screws (M2.0 x 6 mm) (for fastening cable head) Socket cover C
Summary of the content on the page No. 14
Section 1 Configuration Table 1 lists the HS1582ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1582ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the PLQP0120LA-A package 4 Socket cover 1 For installing an PLQP0120LA-A packaged MCU 5 Screws (M2.0 x 10 mm) 4 For fastening cable head 6 Screws (M2.0 x 6 mm) 4 For installing an PLQP0120LA-A packaged MCU 7 Guide pins ( φ1 mm) 3 For
Summary of the content on the page No. 15
Section 2 Connection Procedures Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or remov
Summary of the content on the page No. 16
Section 2 Connection Procedures 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Cable body connector User system interface cable Figure 2 Example of the HS1527KEPH60H Emulator Station Rev. 3.00 Sep. 08, 2008 Page 4 of 18 REJ10J1396-0300
Summary of the content on the page No. 17
Section 2 Connection Procedures 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM w
Summary of the content on the page No. 18
Section 2 Connection Procedures Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. Pin 1 Guide pins 4 projections to apply IC socket epoxy resin adhesive to (NQPACK120SE-ND manufactured by Tokyo Eletech Corporation) Bottom view of IC socket User system Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an PLQP0120LA-A package to the user system. CAUTION Be sure to completely sold
Summary of the content on the page No. 19
Section 2 Connection Procedures 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an PLQP0120LA-A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4. 2.2.4 Fastening Cable Head CAUTION 1. Use a screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N
Summary of the content on the page No. 20
Section 2 Connection Procedures Fasten the user system interface cable head to the IC socket for an PLQP0120LA-A package on the user system with the four screws (M2.0 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.0 x 10 mm