Summary of the content on the page No. 1
REJ10B0173-0100
H8SX/1520 Group FP-100M
User System Interface Cable
User’s Manual
Renesas Microcomputer Development Environment System
HS1527ECH61H
Rev.1.00
Revision Date: Jan. 12, 2005
Summary of the content on the page No. 2
Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammabl
Summary of the content on the page No. 3
Preface The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an FP-100M package for the H8SX/1520 group MCU on the user system. i
Summary of the content on the page No. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station..........................................3 2.2 Connecting User System Interface Cable to User System.................................................5 2.2.1 Installing IC Socket............................
Summary of the content on the page No. 5
Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user system. Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP-100M package. To emulator station Cable body Screws (M2.6 x 12 mm) with flat washers Screws (M2.6 x 6 mm) (for fastening cable head) with flat washers Socket cover Cable head IC socket User system Figure 1 HS1527ECH61H
Summary of the content on the page No. 6
Table 1 lists the HS1527ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1527ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-100M package 4 Socket cover 1 For installing an FP-100M packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 6 mm) 4 For installing an FP-100M packaged MCU (with four flat washers) 7 Documentation 1 U
Summary of the content on the page No. 7
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before co
Summary of the content on the page No. 8
2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Cable body connector User system interface cable Figure 2 Example of the HS1527KEPH60H Emulator Station 4
Summary of the content on the page No. 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the c
Summary of the content on the page No. 10
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3. 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If th
Summary of the content on the page No. 11
Fasten the user system interface cable head to the IC socket for an FP-100M package on the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.6 x 12 mm) with flat wash
Summary of the content on the page No. 12
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jigs Remove jig Cable head User system Figure 4 Fastening Cable Body 8
Summary of the content on the page No. 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100M package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 17.10 (min.) 13.80 (max.) 0.5 x 24 = 12.00 ± 0.05 0.50 ± 0.05 0.30 ± 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad
Summary of the content on the page No. 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. 29.5 17.0 63.50 Unit: mm Tolerance: ±0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10 17.0 29.5 66.04
Summary of the content on the page No. 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-100-054-B51 User system Unit: mm manufactured by Tolerance: ±0.5 mm YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 16.0 21.5
Summary of the content on the page No. 16
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 Nm or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may brea
Summary of the content on the page No. 17
Screws (M2.6 x 6 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System 13
Summary of the content on the page No. 18
Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user system interface cable supports three kinds of clock sources as the MCU clock: an emulat
Summary of the content on the page No. 19
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator. Do not use this cable with any other emulator station. 3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4. While the emulator stati
Summary of the content on the page No. 20
6. A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as shown in figure 12. At shipment, the jumper pin is inserted in the side of pins 1 and 2 of the P4 short connector. For details on the differences between the target MCU and the emulator, refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual. CAUTION Insert the jumper pin in th