Summary of the content on the page No. 1
H8/3337Y Series, H8/3334 Series,
H8/338 Series, H8/330, H8/350
QFP-80A
User System Interface Cable
(HS3337ECH61H)
for E6000 Emulator
User’s Manual
HS3337ECH61HE(D)
Summary of the content on the page No. 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Summary of the content on the page No. 3
Preface Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300 series. The HS3337ECH61H is a user system interface cable that connects an H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-80A package (package code: FP-80A) for the H8/3337Y series, H8/3334 series, H8/338 series, H8/330, or H8/350 MCU on the user system. i
Summary of the content on the page No. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ............................
Summary of the content on the page No. 5
Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3337ECH61H user system interface cable for the FP-80A package. 1
Summary of the content on the page No. 6
To emulator station Cable body Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) (for fastening cable head) with flat washers Socket cover Cable head IC socket User system Figure 1 HS3337ECH61H User System Interface Cable 2
Summary of the content on the page No. 7
Table 1 lists the HS3337ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3337ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2.0 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.0 x 8 mm) 4 For installing an FP-80A-packaged MCU (with four flat washers) 7 Documen
Summary of the content on the page No. 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect t
Summary of the content on the page No. 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow
Summary of the content on the page No. 10
2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC so
Summary of the content on the page No. 11
Fasten the user system interface cable head to the IC socket for an FP-80A package on the user system with the four screws (M2.0 x 12 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 12 mm) with flat washers Cable head Pin 1 IC soc
Summary of the content on the page No. 12
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
Summary of the content on the page No. 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the dimensions for the recommended mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 20.50 (min.) 14.70 (max.) 0.65 19 = 12.35 0.1 + 0.1 0.35 0.65 0.05 - 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad 9
Summary of the content on the page No. 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10
Summary of the content on the page No. 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-080-017-B5 User system Unit: mm manufactured by Tolerance: –0.5 mm YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11
Summary of the content on the page No. 16
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may bre
Summary of the content on the page No. 17
Screws (M2.0 x 8 mm) with flat washers Socket cover MCU Pin 1 mark IC socket (IC149-080-017-B5 manufactured by User system YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 13
Summary of the content on the page No. 18
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user system interfac
Summary of the content on the page No. 19
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca