Summary of the content on the page No. 1
H8/36014 Group, H8/36024 Group FP-64E
User System Interface Cable for E6000 Emulator
User’s Manual
HS36014ECH61H
Renesas Microcomputer Development Environment System
Rev.2.00
2003.12.19
Summary of the content on the page No. 2
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflam
Summary of the content on the page No. 3
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cab
Summary of the content on the page No. 4
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
Summary of the content on the page No. 5
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
Summary of the content on the page No. 6
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
Summary of the content on the page No. 7
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
Summary of the content on the page No. 8
Preface Thank you for purchasing this user system interface cable (HS36014ECH61H) for the Renesas’s original microcomputer H8/36014 series. The HS36014ECH61H is a user system interface cable that connects an H8/36014 series E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-64E package for the H8/36014 series MCU on the user system and to the H8/36024 series expansion I/O board (HS36024EIO61H). i
Summary of the content on the page No. 9
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station (H8/36014 Series)............3 2.2 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series).....5 2.3 Connecting User System Interface Cable to User System................................
Summary of the content on the page No. 10
Section 1 Configuration CAUTION Use an IC149-064-075-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECH61H user system interface cable for the FP-64E package. Figure 1 HS36014ECH61H User System Interface Cable 1
Summary of the content on the page No. 11
Table 1 lists the HS36014ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS36014ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-64E package 4 Socket cover 1 For installing an FP-64E-packaged MCU 5 Screws (M2 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2 x 6 mm) 4 For installing an FP-64E-packaged MCU (with four flat washers) 7 2 CTS screws (M3 x 6 mm) For fasten
Summary of the content on the page No. 12
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station (H8/36014 Series) WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make
Summary of the content on the page No. 13
Figure 2 Connecting User System Interface Cable to Emulator Station 4
Summary of the content on the page No. 14
2.2 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series) WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system, the emulator product, and the expansion I/O board or will result in PERSONAL INJURY. The USER PROGRAM will be
Summary of the content on the page No. 15
E6000 EMULATO Expansion I/O board cable Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 3 Connecting User System Interface Cable to Expansion I/O Board 6 USER INTERFACE CABL E6000
Summary of the content on the page No. 16
2.3 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system,
Summary of the content on the page No. 17
2.3.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4. 2.3.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.13 N•m or less. If the applied torque cannot be a
Summary of the content on the page No. 18
Fasten the user system interface cable head to the IC socket for an FP-64E package on the user system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Figure 4 Connecting User System Interface C
Summary of the content on the page No. 19
2.3.5 Fastening Cable Body Connect the cable body to the cable head. Figure 5 Fastening Cable Body 10
Summary of the content on the page No. 20
2.4 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64E package (IC149-064-075-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. Figure 6 Recommended Dimensions for Mount Pad 11