Renesas FP-100A user manual

User manual for the device Renesas FP-100A

Device: Renesas FP-100A
Category: Computer Hardware
Manufacturer: Renesas
Size: 0.46 MB
Added : 10/8/2013
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Renesas FP-100A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Renesas FP-100A.

For your convenience

If looking through the Renesas FP-100A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Renesas FP-100A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Renesas FP-100A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Renesas FP-100A User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Renesas FP-100A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Renesas FP-100A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

H8/3834 Series, H8/3814 Series,
H8/3877 Series
FP-100A
User System Interface Cable
(HS3834ECF61H)
for E6000 Emulator
User’s Manual

Rev. 4.0
4/1/03
Renesas Technology Corp.


HS3834ECF61HE(D)

Summary of the content on the page No. 2

Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.

Summary of the content on the page No. 3

Preface Thank you for purchasing this user system interface cable (HS3834ECF61H) for the Renesas’s original microcomputer H8/300L series. The HS3834ECF61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-100A package for the H8/3834 series, H8/3814 series, or H8/3877 series MCU on the user system. The H8/3834 series, H8/3814 series, and H8/3877 series MCUs can be emulated using

Summary of the content on the page No. 4

Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ..........................

Summary of the content on the page No. 5

Section 1 Configuration CAUTION Use an IC149-KS-11113-0 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A package IC socket on the user system. Figure 1 shows the configuration of the HS3834ECF61H user system interface cable for the FP-100A package. Figure 1 HS3834ECF61H User System Interface Cable 1

Summary of the content on the page No. 6

Table 1 lists the HS3834ECF61H components. Please make sure you have all of these components when unpacking. Table 1 HS3834ECF61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-100A package 4 Socket cover 1 For installing an FP-100A-packaged MCU 5 Screws (M2.5 x 11 mm) 2 For fastening cable head (with two flat washers) 6 Documentation 1 User’s manual for HS3834ECF61H (this manual) 2

Summary of the content on the page No. 7

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c

Summary of the content on the page No. 8

Figure 2 Connecting User System Interface Cable to Emulator Station 4

Summary of the content on the page No. 9

2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cab

Summary of the content on the page No. 10

2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or a socket contact error may be caused by a crack in the socket sold

Summary of the content on the page No. 11

Figure 3 Connecting User System Interface Cable to User System 7

Summary of the content on the page No. 12

2.2.5 Fastening Cable Body Connect the cable body to the cable head. Figure 4 Fastening Cable Body 8

Summary of the content on the page No. 13

2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100A package (IC149-KS-11113-0: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 27.4 (min.) 21.4 (max.) 0.65 x 29 = 18.85 – 0.1 + 0.1 0.35 0.65 – 0.05 - 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad

Summary of the content on the page No. 14

2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10

Summary of the content on the page No. 15

2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11

Summary of the content on the page No. 16

Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or a socket contact error may be caused by a crack in the socket solde

Summary of the content on the page No. 17

Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulator (HS3L08EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user system interface cable supports tw

Summary of the content on the page No. 18

Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R1 1 M Ω Vcc 0.8 Vcc 0.8 Vcc HCU04 To E6000 emulator HCU04 0.3 Vcc 0.3 Vcc R2 270Ω 55 ns max. 55 ns max. 0 V OSC1 OSC2 Vcc: User System Vcc (3.0 V to 5.0 V) System clock oscillator Subclock input specifications Figure 9 System Clock Oscillator and Subclock Input Specifications 4. Select the MCU type by setting the MCU type switch (SW1) as follows before using the u

Summary of the content on the page No. 19

Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3L08EPI60H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca


Alternative user manuals
# User manual Category Download
1 Renesas FP-112B User manual Computer Hardware 0
2 Renesas FP-128 User manual Computer Hardware 1
3 Renesas H8/3334 Series User manual Computer Hardware 0
4 Renesas 32192 User manual Computer Hardware 4
5 Renesas H8/36024 User manual Computer Hardware 0
6 Renesas 3803L User manual Computer Hardware 0
7 Renesas EDK3687 User manual Computer Hardware 0
8 Renesas H8/3627 Series User manual Computer Hardware 0
9 Renesas 7542 User manual Computer Hardware 0
10 Renesas H8/3637 Series User manual Computer Hardware 0
11 Renesas FP-144 User manual Computer Hardware 0
12 Renesas DP-64S User manual Computer Hardware 0
13 Renesas FP-144G, FP-144H User manual Computer Hardware 1
14 Renesas FP-144F User manual Computer Hardware 0
15 Renesas H8/3007 User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1