Lava Computer PAYLINK IP/232 user manual

User manual for the device Lava Computer PAYLINK IP/232

Device: Lava Computer PAYLINK IP/232
Category: Computer Hardware
Manufacturer: Lava Computer
Size: 0.53 MB
Added : 3/9/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lava Computer PAYLINK IP/232. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lava Computer PAYLINK IP/232.

For your convenience

If looking through the Lava Computer PAYLINK IP/232 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lava Computer PAYLINK IP/232 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lava Computer PAYLINK IP/232 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lava Computer PAYLINK IP/232 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lava Computer PAYLINK IP/232 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lava Computer PAYLINK IP/232. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

LAVA PayLink-IP/232
Quick Installation Guide

Rev. C00

Summary of the content on the page No. 2

Getting Started 1 Congratulations on your purchase of a LAVA PayLink-IP/232. PayLink-IP devicess securely connect payment terminals to payment processors over an Ethernet/TCP/IP connection. Payment terminals that can transmit transaction information over a COM (RS-232) port can send information to the LAVA PayLink-IP/232.The LAVA PayLink-IP/232 establishes an SSL-secured connection to the payment processor, places the serial data in a TCP/IP wrapper and sends it out its Ethernet port. Data movin

Summary of the content on the page No. 3

Hardware Setup 2 1. Connect the power supply to the LAVA PayLink-IP/232 and to AC power.The power (red) LED will light to indicate that the unit is receiving power. 2. Connect an Ethernet cross-over cable to the Ethernet RJ-45 jack of the LAVA PayLink-IP/232. Attach the other end of the crossover network cable to a host PC directly. Network status is indicated by two LEDs on the RJ-45 connector. The left (yellow) LED indicates network activity. It is on by default, turning off when network activ

Summary of the content on the page No. 4

3 3. Open a web browser to the IP address of the PayLink-IP and configure the device as described in the "Configuration" section of this manual. 4. After configuring the LAVA PayLink-IP/232, attach it to your network and connect a payment terminal to its serial port. Serial port activity is indicated by two status LEDs per port.The yellow LED lights when the serial port is transmitting data.The green LED lights when the serial port is receiving data. Serial Tx indicator Serial connector Serial R

Summary of the content on the page No. 5

4 Configuration Configuration consists of the following: A. Configuring network settings B. Port configuration C. Host configuration D. Terminal Side Data and Protocol configuration E. Password selection F. Upgrading software A. Configuring network settings PayLink-IP devices installed on your network will need unique IP addresses.These are set by using a web browser. The factory default network settings for the PayLink-IP are: IP address: 192.168.0.35 Subnet mask: 255.255.255.0 Gateway address:

Summary of the content on the page No. 6

5 5 Opening scr Opening screen een Click "C Click "Configur onfigure" if no passw e" if no passwor ord has been set d has been set,, or ent or enter the er the passw passwor ord f d for the P or the Pa ayLink y yLink you ar ou are c e configuring onfiguring,, and then click and then click "C "Configur onfigure e.." " T The C he Configur onfiguration menu will open. ation menu will open. C Configur onfigura ation Menu tion Menu

Summary of the content on the page No. 7

6 If not using a DHCP server to assign network addresses, choose the "Manually configure" option for Network Settings. In the configuration screen that appears, enter the network settings you wish for that PayLink-IP. Once the new values are entered and accepted, the PayLink-IP will reboot to implement the new network settings. Advanced network settings can also be accessed from this page by clicking on the "Advanced" link. Network Settings NOTE: Changing the network settings of a PayLink-IP dev

Summary of the content on the page No. 8

7 Device name Use this field to supply a “friendly” name for the LAVA PayLink- IP/232 device being configured.The friendly name is optional, and can be chosen to provide a conveniently-remembered name for the unit. IP address The IP address for the LAVA PayLink-IP/232 will identify the device on the LAN on which it is located. Any conventional IP address can be used.The LAVA PayLink-IP/232 ships with its default IP address as 192.168.0.35; ensure that this IP address is available on the LAN onto

Summary of the content on the page No. 9

8 “DHCP enabled” checkbox has been set.The LAVA PayLink-IP/232 will then act as a DHCP client and obtain its IP address from the DHCP server on its LAN that first leases an IP address to the LAVA PayLink-IP/232. Assigned local TCP port Use this dialog box to change the TCP port number assigned to the serial port of the LAVA PayLink-IP/232. By default the LAVA PayLink- IP/232 assigns TCP port 2300 to its serial port; if another device on the network is already using this TCP port number, reassign

Summary of the content on the page No. 10

9 B. Port configuration The PayLink-IP/232 serial port can be configured through a web browser.The settings for the LAVA PayLink-IP/232's serial port should match the settings of the serial port on the payment terminal. Serial Port Settings The following port parameters can be configured for the LAVA PayLink-IP/232: Baud rate This parameter can be set from 110 to 115200 bps. By default this parameter is set to 19200 bps.

Summary of the content on the page No. 11

10 Data bits This parameter can be set from 5 to 8. By default this parameter is set to 8 bits. Parity This parameter can be set even, odd, none, mark, or space. By default this parameter is set to none. Stop bits This parameter can be set 1, 1.5, or 2. By default this parameter is set to 1. Flow control This parameter can be set XON/XOFF, hardware, or none. By default this parameter is set to none. Terminal ID This parameter gives an identifying name, if needed, that a remote server will identi

Summary of the content on the page No. 12

11 C. Host configuration The PayLink-IP/232 Payment Host configuration screen has fields for entering IP address/DNS name and TCP port information for up to four payment processing hosts. Each host can also be configured for the PayLink to use a fallback address By default, these fields are empty. Users will need to supply the addressing information suitable to their specific payment processing hosts on this screen and on the Terminal Side Data and Protocol Configuration screens that can be reac

Summary of the content on the page No. 13

12 D. Terminal Side Data and Protocol Configuration The PayLink-IP/232 permits each host connection to be configured with specific data format and protocol configurations, using the screens shown below.These parameters are described in detail in the PDF manual supplied with the PayLink software. Terminal Side Data and Format Configuration

Summary of the content on the page No. 14

13 Protocol Configuration By default, the LAVA PayLink-IP/232's connection to the payment processor is set up using an SSL Ver. 3.0 link. Disabling this setting will send data over an unsecured TCP/IP link.

Summary of the content on the page No. 15

14 E. Password selection The PayLink-IP/232 password configuration screen can be accessed through a web browser.The password permits securing the PayLink-IP against unauthorized configuration of network settings, port settings, processor gateway settings, and advanced configuration features.The password supplied here is required to access the web browser configuration screens. By default the PayLink-IP is shipped with no password set. LAVA recommends applying a password immediately to any PayLin

Summary of the content on the page No. 16

LAVA Technical Support 9:00 am to 5:30 pm Monday to Friday (Eastern Time) Tel: +416 674-5942 Fax: + 416 674-8262 E-mail: tech@lavalink.com Internet: www.lavalink.com ™ LAVA Computer MFG Inc. Toronto, Canada This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. LAVA Computer MFG I


Alternative user manuals
# User manual Category Download
1 Lava Computer 16650 User manual Computer Hardware 0
2 Lava Computer LAVA Dual Parallel-PCI User manual Computer Hardware 1
3 Lava Computer HQ-ST Plus User manual Computer Hardware 0
4 Lava Computer Lava Parallel LAVA SSerial-PCIe/LP User manual Computer Hardware 0
5 Lava Computer QUATTRO-PCI 3.3V User manual Computer Hardware 0
6 Lava Computer DSerial-PCI/LP Card User manual Computer Hardware 0
7 Lava Computer Lava SP SP-PCI User manual Computer Hardware 0
8 Lava Computer Lava 2SP-PCI User manual Computer Hardware 0
9 Lava Computer LavaPort-Quad User manual Computer Hardware 0
10 Lava Computer LAVA SP-PCI User manual Computer Hardware 0
11 Lava Computer LAVA 8255-PIO User manual Computer Hardware 0
12 Lava Computer LAVA SSerial-PCIe User manual Computer Hardware 0
13 Lava Computer Enhanced Parallel Port Board User manual Computer Hardware 0
14 Lava Computer ISA Bus Bi-Directional Parallel Port Board User manual Computer Hardware 0
15 Lava Computer DSERIAL-PCI 3.3 V User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1