Summary of the content on the page No. 1
GP 7000F
M200, M200R, M400A, M400R, M600, M600R
Edition December 1999
Summary of the content on the page No. 2
Copyrightand Trademarks Copyright © Fujitsu Siemens Computers GmbH 1999. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
Summary of the content on the page No. 3
1 Preface This manual contains the operating instructions for the GranPower7000 (GP 7000F) system from Fujitsu Siemens Computers. A chapter about the connection of Siemens specific de- vices precedes the actual operating instructions. U42335-J-Z775-1-76 1
Summary of the content on the page No. 4
Summary of the content on the page No. 5
2 Console connections to GP 7000F This chapter describes connections to the M200, M200R, M400A, M400R, M600 and M600R models of the Fujitsu Siemens Computers GP 7000F system with a view to attaching existing components of Siemens devices to Fujitsu equipment. Graphical or serial consoles can be connected. The GP 7000F systems do not support SIDATA ! (installation by customer is not allowed). 2.1 Graphical console It is preferable to connect graphical consoles. GP 7000F V.24 (A) system Teleservic
Summary of the content on the page No. 6
Graphical console Console connections to GP 7000F The following technical requirements must be met in order to connect graphical consoles: – PCI graphics controller D:GP70F-CC10 The GP 7000F models can be made into a workstation or server with a graphical console by means of a PCI graphics card featuring a frame buffer. – An RM keyboard and mouse can be connected via the D:GP70F-AN10 interface converter. All models in the GP 7000F server family have a Sun-compatible keyboard/mouse interface. The
Summary of the content on the page No. 7
Console connections to GP 7000F Serial console 2.2 Serial console A converter is used here to convert the 25-pin connector of the GP 7000F system to the usual 9-pin V.24/COM connector. This converter is preinstalled at the factory. A VT100 or VT200 emulation must be available for a serial console to be used. V . 24/ C O M 9-pin 9polig Ds u b 25-pin 25polig 25/9-pin converter U42335-J-Z775-1-76 5
Summary of the content on the page No. 8
Serial console Console connections to GP 7000F 2.2.1 LAN console A Solaris PC is connected as a LAN console via an RCA (Remote Communication Adapter) attached to the V.24 console interface. Up to six servers can be attached to one RCA. GP 7000F RCA V.24 (A) system LAN V.24 (B) console Ethernet hub 10/100 Mbit Eth Teleservice Keyboard/mouse 6 U42335-J-Z775-1-76
Summary of the content on the page No. 9
Console connections to GP 7000F Serial console 2.2.2 Standard PC with terminal emulation a) Windows 98 or NT (with NetTerm, for instance, but not with HyperTerminal) b) LINUX (with Minicom or Seyon) c) Solaris (cu) PC (NT, Windows) GP 7000F V.24 (A) system Teleservice V.24 (B) preferably 10/100 Mbit Eth Keyboard/mouse U42335-J-Z775-1-76 7
Summary of the content on the page No. 10
Teleservice Console connections to GP 7000F 2.2.3 TC20 or T100 Use of these terminals is intended as a migration solution only. α α console α α GP 7000F V.24 (A) system Teleservice V.24 (B) preferably 10/100 Mbit Eth Keyboard/mouse When operating with the LAN console, TC20 or T100 it is not possible to access the i Open Boot PROM using the BREAK signal. 2.3 Teleservice The teleservice modem has to be connected via V.24 to the system board. The modem has to be ordered separately owing to national
Summary of the content on the page No. 11
P321-E102-02EN USER'S MANUAL
Summary of the content on the page No. 12
Summary of the content on the page No. 13
IMPORTANT READING FOR SAFE OPERATION Handling of This Manual This manual contains important information regarding the use and handling of this product. Read this manual thoroughly. Pay special attention to the section "Important Warnings". Use the product according to the instructions and information available in this manual. FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering from damages to their property. Use the product according to this manual. IM
Summary of the content on the page No. 14
THIS PRODUCT IS NOT DESIGNED FOR USE IN ON-LINE CONTROL EQUIPMENT IN HAZARDOUS ENVIRONMENTS SUCH AS OPERATION OF NUCLEAR FACILITIES, AIRCRAFT NAVIGATION OR CONTROL, OR DIRECT LIFE SUPPORT MACHINES. HENCE, IF THESE PRODUCTS ARE USED IN SUCH HAZARDOUS ENVIRONMENTS, FUJITSU LIMITED AND SUN MICROSYSTEMS, INC. DOES NOT WARRANT THEM AT ALL. FUJITSU reserves all the right to make changes to any products herein to improve reliability, function, or design, without further notice and without obligation. F
Summary of the content on the page No. 15
VCCI / FCC label VCCI / FCC label Laser Radiation Statement (EU) Class 1 Laser Product TRADEMARK ACKNOWLEDGMENTS All rights reserved. This product and related documentation are protected by copyright and distributed under licenses restricting its use, copying, distribution, and recompilation. No part of this product or related documentation may be reproduced in any form by any means without prior written authorization of Fujitsu Limited and its licensors, if any. RESTRICTED RIGHTS LEGEND: Use, d
Summary of the content on the page No. 16
TRADEMARKS Fujitsu and the Fujitsu logo are trademarks of Fujitsu Limited. SPARC64 is a registered trademark or trademark of SPARC International, Inc. in the United States and other countries used under license by Fujitsu Ltd. Products bearing SPARC64 trademarks comply with SPARC V9 architecture developed by SPARC International, Inc. Products bearing the SPARC trademarks are based on an architecture originally developed by Sun Microsystems, Inc. " Sun, the Sun logo, Sun Microsystems, Sun Microsy
Summary of the content on the page No. 17
Preface This manual explains the function, configuration, and operation of GP7000F. This manual is intended for the experienced users who have a basic knowledge of computer systems. The structure of this manual is as follows: Introduction to Chapters CHAPTER 1 Product Outline Chapter 1 describes the distinctive features of GP7000F. CHAPTER 2 M200 Main Cabinet Chapter 2 explains the device configuration and operation of M200 Main Cabinet. CHAPTER 3 M200R Main Cabinet Chapter 3 explains the device c
Summary of the content on the page No. 18
CHAPTER 12 External Interface Chapter 12 explains the external interface of the main cabinet such as UPS Control Interface, RS232C Interface, and Centronics Interface. CHAPTER 13 RCI Setting Chapter 13 explains the description of RCI commands to be used for managing nodes. CHAPTER 14 Troubleshooting Chapter 14 will help the user isolate the cause of system failures, and provides suggested solutions. Conventions for Warning Messages A warning message consists of a signal and statements. The signa
Summary of the content on the page No. 19
vii
Summary of the content on the page No. 20
Important Warnings The following are cautions found in this manual. They have been compiled here with corresponding page references. A hazardous situation could result in minor or moderate personal injury if the CAUTION user does not perform the procedure correctly. Also, damage to the product or other property may occur. Task Warning Normal Operation