GD Commerce International Inc.EDA-M300 user manual

User manual for the device GD Commerce International Inc.EDA-M300

Device: GD Commerce International Inc.EDA-M300
Category: Computer Hardware
Manufacturer: GD Commerce
Size: 1.78 MB
Added : 4/1/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GD Commerce International Inc.EDA-M300. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GD Commerce International Inc.EDA-M300.

For your convenience

If looking through the GD Commerce International Inc.EDA-M300 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GD Commerce International Inc.EDA-M300 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GD Commerce International Inc.EDA-M300 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GD Commerce International Inc.EDA-M300 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GD Commerce International Inc.EDA-M300 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GD Commerce International Inc.EDA-M300. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Page - 1 Windmill
Hardware Specification
In order to run Windmill or PanCom software the following system requirements must be satisfied:
1.1 PC Requirements
Pentium Processor running Windows 95 or later
The display must be run in a resolutions mode of 800 x 600 or greater.
Serial port Com1, Com2 or Com3
As some software takes priority over the serial ports, it must be ensured that any such software has been
terminated if using the same serial port as used by this software.
1.2 Fire Ala

Summary of the content on the page No. 2

Page - 2 Windmill 3.2 Installing Program files 3.2.1 Installing Windmill from CD · Before starting any installation ensure any other applications have terminated to avoid software conflicts. · Insert the CD in the CD player. · Using Windows Explorer or My Computer select the CD drive. - usually D: · Double click on the windmill directory. · Contained in the windmill directory will be a file named SETUP.EXE - typically assigned a 'computer' icon - but this will depend on your PC. · Doub

Summary of the content on the page No. 3

Page - 3 Windmill You will be prompted to change the disk at various stages but apart from this the procedure is very similar to that detailed in section 3.2.1. 3.2.4 Installing PanCom software from 3.5" disks This is again very similar to the above installation of Windmill from 3.5" disks. Instead of copying the DISK folders contained in the windmill folder, simply follow the above instructions using the DISK folders contained in the PanCom Directory. 3.3 Viewing Datasheets, Manuals and

Summary of the content on the page No. 4

Page - 4 Windmill 5.0 Using Windmill Software 5.1 Defining a new system. In order to create a new system click on the ‘create new’ button. The screen will display blank panel and device information as shown in figure 5.2. To change the settings go to section 5.4 5.2 Loading from an earlier system stored on a disk To load data from a previous system saved on disk click on the ‘Load from disk’ button. A screen allowing you to select a file from the disk as shown in figure 5.1 is displayed.

Summary of the content on the page No. 5

Page - 5 Windmill Device Type The device type of the unit installed. To ensure correct operation this value must be correct. The codes follow the product code. If you are unsure then the ‘X’ option must be used. Zone The zone number must be programmed between the following values EDA-M100 system 1 – 999 zones EDA-M200 system 1-20 zones Locations Text The device location text can be set using a maximum of 37 characters Day/Night Mode On If analogue devices are being used (500 and 600 range

Summary of the content on the page No. 6

Page - 6 Windmill Location text The location text cannot be changed on this screen and is displayed for reference only. Zone number The zone number cannot be changed on this screen and is displayed fore reference only. Initial Delay: Setting the initial delay will cause the system to display an alarm condition immediately and then delay for however many seconds set before operating any sounders or outputs. If any outputs or sounders are required to operate immediately in the event of an ala

Summary of the content on the page No. 7

Page - 7 Windmill Radio Sounders Tone The tone for the radio sounder can be set. The default tone is tone 4 (swept Tone). If EDA-A910 hardwired sounders are being used to match the tone of the radio units then the tone for the hardwired sounders is set inside the individual units. Radio Sounder Auxiliary If the radio sounders are fit- ted with auxiliary outputs or output devices are fitted then this should be checked to operate the auxiliary output. Radio Sounders Area If the radio sounder

Summary of the content on the page No. 8

Page - 8 Windmill Alert When Alert is pressed on the corresponding panel the sounder circuits, auxiliary relays and radio sounders operate as programmed. For a more detailed description of the sounder circuits, auxiliary relays and radio sounders see the device programming section (5.4.1) Relay operation silence alarm When Reset is pressed on the fire alarm panel any auxiliary relays that have been programmed to operate in a fire alarm condition will cancel. In order to cancel these when ‘S

Summary of the content on the page No. 9

Page - 9 Windmill Display Low Batteries NOT IMPLEMENTED Timeout Values The system has many settings or operations, which after a predetermined period of time automatically cancel. This is where these values are set. Refer to the EDA-M100 manual for descriptions of these values Analogue Global Options Only required for analogue systems that use the analogue range of detectors. % level changes when changing from day to night mode. + sets the units more sensitive, - sets the units less sensi

Summary of the content on the page No. 10

Page - 10 Windmill When downloading settings to the EDA-M200 panel, the options and messages must be performed sepa- rately. Select messages first and download them to the panel. Then select options and download them to the panel. 5.9 Print System Settings to Disk In order to print the settings, the system allows the settings to be stored in a file on the computers disk drive. This can then be imported into an editor or word-processor, formatted and then printed. To Print Settings Click o

Summary of the content on the page No. 11

Page - 11 Windmill Since we want to download from a panel click 'Download from Panels' 6.1.1 Site Information Screen Clicking 'Download from Panels' you will be presented with the screen shown Below: Our site name is 'College' so this is entered in the site name field. In the next field we enter the number of panels on the system. In this example our system has 3 panels so this is entered. Once the number of panels has been entered click continue. To return to the main screen click back.

Summary of the content on the page No. 12

Page - 12 Windmill Simply select the location and click Save. Once you are happy with the save location click next >>. 6.1.3 File Control and Panel Download Screens Following on from the previous screen you are presented with the screen shown Below: From this screen you can add new panels to the system, go to the panel download screen and remove any downloads that you have already completed. To add a panel to the system click on Add New Panel, in this case Panel 04 would be created. [Note

Summary of the content on the page No. 13

Page - 13 Windmill Providing the details shown are correct connect the PC to the module port of the panel, click continue with the mouse and press the dump button inside the panel Twice. After a few seconds the panel will start communicating with the PC and a progress bar will appear where the continue button was previously: Once the download has been completed click Next and you will be returned to the file control screen. Upon returning to the file control screen the panel you have just

Summary of the content on the page No. 14

Page - 14 Windmill Data analysis is made up of three main stages: i) Processing of Downloaded Data, ii) Correction of corrupted lines (if any), iii) Report Generation. At this stage files can be added or removed using the corresponding buttons. Clicking on Process Files proceeds with the analysis. 6.1.4i File Processing Upon processing the data from each file will be read and checked for corruption, if detected a new screen will appear to deal with the corrupt line. Our example download

Summary of the content on the page No. 15

Page - 15 Windmill If the corrected line did not pass the validity checks or was altered by the user in such a way that it no longer passed its validity checks then the Use >> button would be de-activated until the line passed these checks. For more information on corrupt files see Appendix A. Once the processing is completed we are informed that there is no uncorrected corruption and presented with a screen similar to the one below: As can be seen although it has been corrected the origi

Summary of the content on the page No. 16

Page - 16 Windmill If this highest strength is below the standard 37 then two warning stars are displayed after the strength. The highest strength is also flagged if it is stored as 0, this time using a '-?', to indicate that it may be a panel anomaly. The highest panel strength is again included along with the next four highest in a list of the five highest panel communication strengths for this device. The weak strengths only option is very similar to the full re- port except that you ar

Summary of the content on the page No. 17

Page - 17 Windmill Our example uses townhall files 1, 2 and 3. As stated these are selected by holding the control key and selecting each file. Upon clicking Open you will be returned back to the control screen where the selected files will be displayed in the downloaded files list. If required, files can be removed by selecting them on the list and clicking remove file.... Once all the re- quired files are present click on Analyse Downloads >> and follow the steps in Example 1 section 5.1.

Summary of the content on the page No. 18

Page - 18 Windmill Example M200 Download GD Systems


Alternative user manuals
# User manual Category Download
1 GD Commerce International Inc.EDA-M350 User manual Computer Hardware 0
2 GD Commerce International Inc.EDA-M100 User manual Computer Hardware 2
3 GD Commerce International Inc.EDA-M150 User manual Computer Hardware 0
4 GD Commerce International Inc.Control and Booster Panels User manual Computer Hardware 0
5 GD Commerce International Inc.EDA-M200 User manual Computer Hardware 0
6 Sony MSAKIT-PC4A User manual Computer Hardware 2
7 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
8 Philips MATCH LINE 9596 User manual Computer Hardware 17
9 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
10 Philips PSC702 User manual Computer Hardware 1
11 Sony MRW62E/S1/181 User manual Computer Hardware 3
12 Sony 64GB SDHC Class 10 Memory Card Readers SF32N4/TQM User manual Computer Hardware 1
13 Philips SAA7345 User manual Computer Hardware 1
14 Philips SBC MC8650 User manual Computer Hardware 268
15 Philips PSC 605 User manual Computer Hardware 1