Fujitsu M5000-CL09-PI01 user manual

User manual for the device Fujitsu M5000-CL09-PI01

Device: Fujitsu M5000-CL09-PI01
Category: Computer Hardware
Manufacturer: Fujitsu
Size: 1.21 MB
Added : 4/1/2014
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu M5000-CL09-PI01. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu M5000-CL09-PI01.

For your convenience

If looking through the Fujitsu M5000-CL09-PI01 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu M5000-CL09-PI01 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu M5000-CL09-PI01 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu M5000-CL09-PI01 User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu M5000-CL09-PI01 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu M5000-CL09-PI01. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




Issue June 01, 2008
®
®
Product SPARC Enterprise M5000
SPARC Enterprise M5000

Server

Pages 38


®
SPARC Enterprise M5000 Configuration Diagram
New products: M5000-GR20, M5000-CL09-PI01, M5000-CL10-PI01, M5000-CL11-12-PI01
Withdrawn products:
Some minor corrections: Chapter “Mounting additional Memory with different sizes”

SystemArchitect PRIMEPOWER (PW) Hotline
For further questions related to configurations for SE M5000 Systems with PC-ARCHITECT or SYSTEM-

Summary of the content on the page No. 2

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 2 / 38 Contents Recommended 19"- rack PRIMECENTER 2 with 1100 mm depth 3 Overview M4000 and M5000 4 System Architecture 5 ® Product Overview SPARC Enterprise M5000 6 Features 6 M5000 Server Product ID List 9 M5000 COD (Capacity on Demand) Server Product ID List 10 M5000 COD (Capacity on Demand) CPU Right to Use (License) Product ID List 10 M5000 Internal Storage Device Product ID List 10 M5000 Filter Prod

Summary of the content on the page No. 3

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 3 / 38 Recommended 19"- rack PRIMECENTER 2 with 1100 mm depth 24 HU height 38 HU height 46 HU height + 2 x 2 HU vertical + 3 x 2 HU vertical + 4 x 2 HU vertical S26361-K826-V212 S26361-K826-V213 S26361-K826-V214 ® SPARC Enterprise M5000 servers can be mounted in PCR2 Rack versions with 1100 mm depth. If the mounting kits do NOT fit to the required rack, please order additional kits separately. For more

Summary of the content on the page No. 4

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 4 / 38 Overview M4000 and M5000 ® ® SPARC Enterprise M4000 SPARC Enterprise M5000 Enclosure Rack 6U Rack 10U ® ® CPU / Processor Chips (multi-core, 4 x 2.15GHz SPARC 64VI 8 x 2.15GHz SPARC 64VI multi-thread (VMT)) (2 per module) (2 per module) Cores / Threads per System 8 / 16 16 / 32 Cores / Threads per processor Chip 2 / 2 Primary Cache per core Instruction 128 KB / Data 128 KB SLC (Second Level Cach

Summary of the content on the page No. 5

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 5 / 38 System Architecture PRIMECENTER 2 Rack PC LAN 24U, 38U, 46U deep 1100mm Console SPARC Enterprise M5000 10U Basic Config up to 8x CPU (up to 16 core) / 256 GB MEM / 4x Hard disk / Solaris 2x PCI-X and 8x PCI-express slot PC Up to 8 CPU, 4 Module (SPARC64 VI). Up to 16 core (2 Threads per core) 2.15GHz / 5MB SLC for 1 CPU (2 cores) CPU order# Type Serrial LAN HUB SEL[XY]1A1U 2 CPU, 2.15GHz on

Summary of the content on the page No. 6

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 6 / 38 ® Product Overview SPARC Enterprise M5000 ® SPARC ENTERPRISE M5000 is a midrange server developed using the expertise of Fujitsu and Sun Microsystems. It has been designed to be the best choice in mission-critical computing solutions. High scalability comes from eight CPU chips (16 cores) and is backed by exceptional reliability and excellent means for asset investment protection. Based on SMP (Symmetric

Summary of the content on the page No. 7

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 7 / 38 4. Very flexible partitioning functions are provided. • Multiple independent systems can be built on a single server called partitions or domains. • Each partition can individually be configured. • Up to four partitions are supported. • The motherboard on which CPU- and memory-modules are mounted is sub-divided into eight parts, and the two I/O board are sub-divided into four. A combination of sub-part

Summary of the content on the page No. 8

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 8 / 38 9. Configuration Diagram of the Main Unit * Areas indicated in blue show components belonging to the base units; those indicated in red show options (purchased separately, but see also base unit description). 10. Hardware for M5000 • Motherboard The motherboard carries CPU modules and memory modules. Four CPU modules (eight CPU chips) and eight memory modules (64 DIMMs) can be mounted. The mot

Summary of the content on the page No. 9

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 9 / 38 M5000 Server Product ID List PART NUMBER LONG DESCRIPTION SHORT DESCRIPTION M5000 family: ® SEFPAAA1S Fujitsu-Siemens Computers SPARC Enterprise M5000 server. SE M5000 2.1GHz Includes M5000 system, 2x 2.1GHz CPUs (1 2x 2.1GHz CPU Modules), 2P16GB 2x73GB 16GB system memory (2 ea. 8GB memory boards), 2x 73GB HDD, 4 PSU, 1 I/O tray ® SEFPBAA1S Fujitsu-Siemens Computers SPARC Enterprise M5000 se

Summary of the content on the page No. 10

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 10 / 38 M5000 COD (Capacity on Demand) Server Product ID List PART NUMBER LONG DESCRIPTION SHORT DESCRIPTION M5000family: SEFRCDB1S FSC SPARC Enterprise M5000 COD (Capacity On Demand) server. M5CoD 2.1GHz Includes 8x 2.15GHz CPUs (4 CPU boards with 2 x CPUs each, 5MB on- 8P64GB 4x73GB chip L2 cache) and 64GB system memory (4 memory modules with 8 x 2xI/O tray 2GB DDR2 DIMMs), 4 x 73GB SAS hard disks, 1

Summary of the content on the page No. 11

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 11 / 38 M5000 Power Cords for Rack internal use Product ID List Attention: For each PSU a Power Cord must be ordered for Rack internal connection (thickly marked in table below) to the Socket strip! Note: M5000 requires 4x 16A power cords, each I/O-Box requires 2x 10A power cords. Power Cord, Is a Standard Part of each to a Rack internal Socket strip, 16 A System PSU. For System Base Units! Socket st

Summary of the content on the page No. 12

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 12 / 38 Power supply unit and power supply connections ® SPARC ENTERPRISE M5000 has 2+2 redundant power supply units (four in total). Connect the power supply units as follows. Single Power Feed Dual Power Feed HDD#1 HDD#3 DAT DAT HDD#0 HDD#2 Power Power Power Power supply supply supply supply unit #1 unit #0 unit #2 unit #3 If an uninterruptible Power Supply (UPS) is used it shall only supply one of t

Summary of the content on the page No. 13

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 13 / 38 M5000 PCI Card Product ID List Ethernet Controller Overview Order PCI for Factory Description Max Max in Supported Numbers options: Bus Integration within a an in I/O-Box type or X-option System I/O-boat X7281A-2 X-option Yes PCI-e Dual Port Gb Ethernet MMF 8 2 Fact.- 7281A-2 Yes Integrat. X7280A-2 X-option Yes PCI-e Dual Port Gb Ethernet UTP 8 2 Fact.- 7280A-2 Yes Integrat. X4447A-Z

Summary of the content on the page No. 14

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 14 / 38 Fibre Channel Host Bus Adapters Overview Order PCI for Factory Description Max Max in Supported Numbers options: Bus Integration within a an in I/O-Box type: or X-option System I/O-boat SG-XPCIE2FC-QF4 X-option Yes Dual 4Gb Fiber Channel Network PCI-e 8 6 Adapter, RoHS 6 compliant Fact.- SG-PCIE2FC-QF4 Yes Integrat. SG-XPCIE2FC-EM4 X-option Yes Dual 4Gb Fiber Channel Network PCI-e 8 6 Adapte

Summary of the content on the page No. 15

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 15 / 38 Console Connection For APL a personal computer (PC) or workstation is required for system control and maintenance work. This console must be setup prior to installation of APL. The XSCF is accessed using this console. The console ports of each partition are accessed via XSCF. XSCF and the console need to be connected via LAN. If you forget the XSCF-sign on password, you will need to connect to XSCF via

Summary of the content on the page No. 16

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 16 / 38 Console connection example (Field engineer connects temporarily a PC via LAN (shown as blue line) or RS-232C (shown as dotted line) as required to provide maintenance) Note: For the HUB in the picture our LAN Switch D:GP70F-AL21 can be ordered. Console connection example (the console path is duplicated. Field engineer connects temporarily a PC via LAN (shown as blue line) or RS-232C (shown as dotted

Summary of the content on the page No. 17

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 17 / 38 Specifications for the PC (or the workstation, etc.) Description Remarks CPU Pentium3 1 GHz or greater Equivalent CPUs i.e. ® SPARC AMD are suitable. Memory 512 MB or greater OS Windows XP One of the OS listed Windows2000 on the left is required. RedHat Linux Solaris I/O CD-ROM/DVD-ROM (either internal or external device is available) LAN (1000Base-T, 100Base-TX, or 10Base-T) RS-232C (not nec

Summary of the content on the page No. 18

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 18 / 38 Partitioning ® SPARC ENTERPRISE M5000 supports partitioning in which a single server can be divided into multiple independent systems. • Partitioning creates multiple independent systems which are called partitions or domains. • The basic hardware resource required for partitioning is a Physical System Board (hereafter referred to as PSB). A PSB consists of a motherboard with or without connection to an

Summary of the content on the page No. 19

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 19 / 38 If only one partition is configured with both PSBs in Uni-XSB mode but no CPU- and MEM-modules are mounted on PSB#1, then HDDs and PCI slots on the additional I/O board cannot be used (Areas shaded black in the figure below are not equipped with CPU- and MEM-modules).

Summary of the content on the page No. 20

® Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC Enterprise M5000 Page 20 / 38 2) Quad XSB Because Quad-XSB allows to configure several partitions in units of individual CPU chips (two cores) it is the optimized way to create small partitions. Quad-XSB is equivalent to the XSB definition for PRIMEPOWER. Division Type: Quad-XSB PSB (consists of 1/2 motherboard and an I/O board) is divided into four partitions with 1 CPU chip and a set of memory (8 DIMMs) each. PSBs can be d


Alternative user manuals
# User manual Category Download
1 Fujitsu D2529 User manual Computer Hardware 2
2 Fujitsu D2151 User manual Computer Hardware 341
3 Fujitsu MB91F109 FR30 User manual Computer Hardware 0
4 Fujitsu SYSTEM BOARD D2530 User manual Computer Hardware 43
5 Fujitsu FM3 32-Bit Microcontroller MB9B100A User manual Computer Hardware 0
6 Fujitsu D2156 User manual Computer Hardware 47
7 Fujitsu D2630 User manual Computer Hardware 2
8 Fujitsu FM3 32-Bit Microcontroller MB9B500A User manual Computer Hardware 0
9 Fujitsu F2MC-8L MB89202 User manual Computer Hardware 4
10 Fujitsu XG Series P3NK-4452-01ENZD User manual Computer Hardware 4
11 Fujitsu FM3 32-Bit Microcontroller MB9B300A User manual Computer Hardware 1
12 Fujitsu GranPower7000 (GP 7000F) User manual Computer Hardware 3
13 Fujitsu FR81 User manual Computer Hardware 11
14 Fujitsu M200 User manual Computer Hardware 0
15 Fujitsu E600 User manual Computer Hardware 6
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1