Trane GAT2A0C48S41SA user manual

User manual for the device Trane GAT2A0C48S41SA

Device: Trane GAT2A0C48S41SA
Category: Air Conditioner
Manufacturer: Trane
Size: 2.87 MB
Added : 3/31/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane GAT2A0C48S41SA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane GAT2A0C48S41SA.

For your convenience

If looking through the Trane GAT2A0C48S41SA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane GAT2A0C48S41SA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane GAT2A0C48S41SA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane GAT2A0C48S41SA User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane GAT2A0C48S41SA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane GAT2A0C48S41SA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Modular
Multi-position
Air Handlers
GAT2A0B42S31SA
GAT2A0C48S41SA
GAT2A0C60S51SA
PUB. NO. 22-1857-03

Summary of the content on the page No. 2

Features and Benefits • Unique Cabinet Design • Primary/Secondary Condensate • Low Voltage Terminal Connection - Double Wall Foamed and Formed Point Connections Cabinet System • Enhanced Coil Fin Patented • Premarked Conduit Connection - Water Proof Cabinet Design Locations • Blow Through Design - R-4.2 Insulating Value (Avg. Insulating • Vortica Blower with Integrated Slide • PSC 3 Speed Motor on 3.5 & 4 ton Value R-8.2) Deck for Easy Removal models - Composite Foamed Cabine

Summary of the content on the page No. 3

Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benefits 5 General Data 6 GAT2A0B42S31SA 6 GAT2A0C48S41SA 6 GAT2A0C60S51SA 6 Performance Data 7 Electrical Data 10 Wiring Diagrams 13 Field Wiring 15 Convertibility 17 Dimensions 18 Pub. No. 22-1857-03 3

Summary of the content on the page No. 4

Optional Equipment OPTIONAL EQUIPMENT FOR AIR HANDLERS Accessory Number Description Fits Cabinet Size BAYEAAC05BK1A Electric Heater, 5kW, Breaker, 24V Control, 1 Ph A to C BAYEAAC05LG1A Electric Heater, 5kW, Lugs, 24V Control, 1 Ph A to C BAYEAAC08BK1A Electric Heater, 8kW, Breaker, 24V Control, 1 Ph A to C BAYEAAC08LG1A Electric Heater, 8kW, Lugs, 24V Control, 1 Ph A to C BAYEAAC10BK1A Electric Heater, 10kW, Breaker, 24V Control, 1 Ph A to C BAYEAAC10LG1A Electric Heater, 10kW, Lugs, 24V Contr

Summary of the content on the page No. 5

Unique Cabinet Design Features and Benefits 2 Precision Durable 1 Unique Cabinet Design Door Seals 0 Thermal Expansion 5 Conduit Valve (TXV) Connections 3 Refrigeration Connections e Integrated Horizontal Drain Pans 8 All Aluminum Coil 4 Condensate Connections r Safety Door Switch TM 7 Vortica Blower and Deck 6 Tool-less Door 9 Labeled Panels Fasteners and Connections w Compact 20.8” Depth q Maximum width with Doors Removed is 23.5” 8 All Aluminum Coil 1 Unique Cabinet Design - Int

Summary of the content on the page No. 6

General Data PRODUCT SPECIFICATIONS GAT2A0B42S31SA GAT2A0C48S41SA MODEL GAT2A0C60S51SA 208-230/1/60 208-230/1/60 RATED VOLTS/PH/HZ. 208-230/1/60 See O.D. Specifications See O.D. Specifications See O.D. Specifications RATINGS 1 Plate Fin Plate Fin INDOOR COIL — Type Plate Fin 3 - 14 3 - 14 Rows — F.P.I. 4 - 14 5.04 5.50 Face Area (sq. ft.) 5.50 3/8 3/8 Tube Size (in.) 3/8 TXV TXV Refrigerant Control TXV 3/4 NPT 3/4 NPT Drain Conn. Size (in.) 2 3/4 NPT See Outline Drawing See Outline Drawing S

Summary of the content on the page No. 7

General Data GAT2A0B42 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0B42S31SA EXTERNAL STATIC AIRFLOW (CFM) (in w.g) Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 † 1 3 2 † 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.2 1546 1421 1313 1449 1260 1120 0.3 1488 1380 1280 1401 1233 1099 0.4 1425 1329 1233 1348 1193 1065 0.5 1353 1264 1178 1281 1140 1023 0.6 1259 1182 1108 1202 1075 958 0.7 1145 1081 995 1102 965 868 0.8 982 909 839 926 817 753 0.9 788 759 731 761

Summary of the content on the page No. 8

Performance Data GAT2A0C48 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C48S41SA EXTERNAL STATIC AIRFLOW (CFM) (in w.g) Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 † 1 3 2 † 1 0 1904 1711 1541 1652 1455 1305 0.1 1881 1687 1529 1640 1450 1288 0.2 1844 1666 1511 1619 1425 1271 0.3 1806 1637 1485 1592 1410 1249 0.4 1766 1602 1454 1559 1381 1231 0.5 1716 1560 1420 1524 1351 1198 0.6 1659 1513 1380 1484 1321 1165 0.7 1594 1458 1333 1434 1283 1127 0.8 1525 1395 1277 1376 1229 1067 0.9 1

Summary of the content on the page No. 9

Performance Data GAT2A0C60 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C60S51SA EXTERNAL STATIC AIRFLOW (CFM) (in w.g) Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 5 4 † 3 2 1 5 4 † 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582 0.2 2130 1889 1803 1667 1554 2121 1961 1795 1659 1545 0.3 2102 1850 1774 1628 1523 2090 1919 1763 1617 1511 0.4 2066 1818 1741 1596 1491 2052 1884 1727 1582 1477 0.5 2015 1785 1707 1564 1457 1998

Summary of the content on the page No. 10

Performance Data WIRING DATA GAT2A0B42S31SA 240 VOLT 208 VOLT Heater No. Heater Heater Model of Minimum Maximum Minimum Maximum Capacity Capacity Amps Amps No. Circuits Circuit Overload Circuit Overload per per Ampacity Protection Ampacity Protection kW BTUH Circuit kW BTUH Circuit No Heater - - - 2.7** 3 15 - - 2.7** 3 15 BAYEAAC05++ 1 4.80 16400 20 28 30 3.60 12300 17.3 25 25 BAYEAAC08++ 1 7.68 26200 32 43 45 5.76 19700 27.7 38 40 BAYEAAC10++ 1 9.60 32800 40 53 60 7.20 24

Summary of the content on the page No. 11

Performance Data WIRING DATA GAT2A0C48S41SA 240 VOLT 208 VOLT Heater No. Heater Heater Model of Minimum Maximum Minimum Maximum Capacity Capacity Amps Amps No. Circuits Circuit Overload Circuit Overload per per Ampacity Protection Ampacity Protection kW BTUH Circuit kW BTUH Circuit No Heater - - - 3.1** 4 15 - - 3.1** 4 15 BAYEAAC05++ 1 4.80 16400 20.0 29 30 3.60 12300 17.3 26 30 BAYEAAC08++ 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYEAAC10++ 1 9.60 32800 40.0 54 60 7

Summary of the content on the page No. 12

Performance Data WIRING DATA GAT2A0C60S51SA 240 VOLT 208 VOLT Heater No. Heater Heater Model of Minimum Maximum Minimum Maximum Capacity Capacity Amps Amps No. Circuits Circuit Overload Circuit Overload per per Ampacity Protection Ampacity Protection kW BTUH Circuit kW BTUH Circuit No Heater - - - 7.6** 10 15 - - 7.6** 10 15 BAYEAAC05++ 1 4.80 16400 20.0 35 35 3.60 12300 17.3 31 35 BAYEAAC08++ 1 7.68 26200 32.0 50 50 5.76 19700 27.7 44 45 BAYEAAC10++ 1 9.60 32800 40.0 60 60

Summary of the content on the page No. 13

WIRING DIAGRAM FOR GAT2A0B42 AND GAT2A0C48 AIR HANDLERS

Summary of the content on the page No. 14

WIRING DIAGRAM FOR GAT2A0C60 AIR HANDLERS

Summary of the content on the page No. 15

Green Field Wiring GAT2 AIR HANDLERS WITH SINGLE SPEED COOLING Air Handler Hook-up Diagram Cooling W2 Pink W3 Brown W1 White Blue Air Handler Air Conditioner Comfort Control White W White Blue Yellow Green Green G Yellow Yellow Y Orange O Red Red R Blue Blue B B - Blue Y - Yellow Field wiring • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. Pub. No. 22-1857-03 15 Red

Summary of the content on the page No. 16

Green Field Wiring GAT2 AIR HANDLERS WITH SINGLE SPEED HEAT PUMP Air Handler Hook-up Diagram Heat Pump HP W2 Pink W3 Brown W1 White Blue Black Air Handler (X2) Yellow Comfort Control Orange Red Blue White W White Green G Green Yellow Yellow Y Orange Orange O Red Red R Blue Blue B R - Red B - Blue Y - Yellow • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat Field wiring 16 Pub. No. 22-1857-03 Red

Summary of the content on the page No. 17

GAT2 Convertibility * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct position Multi-position 1 Refrigerant Air Handler Connections Upflow Condensate Drains Vertical Upflow* (as shipped) Refrigerant Refrigerant Connections Connections 1 Airflow Airflow 1 Horizontal Right Horizontal Left Condensate Condensate Drains Drains Horizontal Left* Horizontal Right* Pub. No. 22-1857-03 17 Airflow

Summary of the content on the page No. 18

W Dimensions GAT2 AIR HANDLER DIMENSIONAL DATA H Model No. H W D GAT2A0B42 55.7 21.3 21.75 GAT2A0C48 56.9 23.5 21.75 GAT2A0C60 61.7 23.5 21.75 GAT2 AIR HANDLERS ARE ALL TWO PIECE CABINETS. 18 Pub. No. 22-1857-03 D

Summary of the content on the page No. 19

GAT2 OUTLINE DRAWING MODEL NO. A B C D E F H FLOW GAS LINE CONTROL BRAZE GAT2A0B42 55.7 45.5 18.4 21.3 18.4 9.2 24.8 TXV 7/8 GAT2A0C48 56.9 46.7 20.5 23.5 20.5 10.3 24.2 TXV 7/8 GAT2A0C60 61.7 51.5 20.5 23.5 20.5 10.3 27.0 TXV 7/8 Pub. No. 22-1857-03 19

Summary of the content on the page No. 20

03/12 Trane 6200 Troup Highway Tyler, TX 75707 The manufacturer has a policy of continuous product and product data improvement and it reserves the right www.trane.com to change design and specifications without notice.


Alternative user manuals
# User manual Category Download
1 Trane 2TTZ9 User manual Air Conditioner 434
2 Trane 4TTX4 User manual Air Conditioner 86
3 Trane Central Air Conditioning User manual Air Conditioner 223
4 Trane 2TTB3 User manual Air Conditioner 65
5 Trane 2TTX4 User manual Air Conditioner 24
6 Trane 4TTX6 User manual Air Conditioner 11
7 Trane FTXS18DVJU User manual Air Conditioner 23
8 Trane FTXS24DVJU User manual Air Conditioner 9
9 Trane FTXS15DVJU User manual Air Conditioner 13
10 Trane LO User manual Air Conditioner 9
11 Trane 4TTX3 User manual Air Conditioner 5
12 Trane Genius PKG-PRC007-EN User manual Air Conditioner 9
13 Trane INTELLIPAK RT-SVX10C-EN User manual Air Conditioner 112
14 Trane New Stylus MS-SVN015-EN User manual Air Conditioner 27
15 Trane PTAC-SVX01C-EN User manual Air Conditioner 12
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21