Summary of the content on the page No. 1
RMC 7189
1U Rackmount System
User Manual
RMC7189: 1U Rackmount Computer comes with
Intel Xeon X5600/E5600/L5600 series processor
Intel Xeon X5500/E5500/L5500 series processor
© Copyright 2009 Acnodes, Inc.
661 Brea Canyon Rd., Suite 3
All rights reserved. Product description and product specifications
Walnut, CA 91789 are subject to change without notice. For latest product information,
tel: 909.598.7388, fax: 909.598.0218 please visit Acnodes’ web site at www.acnodes.com.
Summary of the content on the page No. 2
RMC 7189 1U Rackmount System The information in this User's Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. Acnodes Corporation, reserv
Summary of the content on the page No. 3
RMC 7189 1U Rackmount System Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the Acnodes RMC7189. Installation and maintainance should be per- formed by experienced technicians only. Manual Organization Chapter 1: Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the embedded board and
Summary of the content on the page No. 4
RMC 7189 1U Rackmount System Chapter 5: Advanced Motherboard Setup Chapter 5 provides detailed information on the embedded board, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the motherboard. Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the RMC7189 1U rackmount server chassis. You should follow the procedures given in this chapter when
Summary of the content on the page No. 5
RMC 7189 1U Rackmount System Table of Contents CHAPTER 1 INTRODUCTION 1-1 Overview .......................................................................................................... 1 1-2 Serverboard Features..................................................................................... 2 Processor ........................................................................................................ 2 Memory ........................................................................
Summary of the content on the page No. 6
RMC 7189 1U Rackmount System Reduced Airflow ...............................................................................................7 Mechanical Loading .........................................................................................7 Circuit Overloading............................................................................................7 Reliable Ground.................................................................................................7 2-4 Installing the Sy
Summary of the content on the page No. 7
RMC 7189 1U Rackmount System 4-3 ESD Precautions ............................................................................................. 21 4-4 Operating Precautions .................................................................................... 22 CHAPTER 5 ADVANCED MOTHERBOARD SETUP 5-1 Handling the Serverboard ................................................................................ 23 Precautions ..............................................................................
Summary of the content on the page No. 8
RMC 7189 1U Rackmount System CHAPTER 6 ADVANCED CHASSIS SETUP 6-1 Static-Sensitive Devices..................................................................................... 50 Precautions ......................................................................................................... 50 6-2 Control Panel ...................................................................................................... 51 6-3 System Cooling..........................................................
Summary of the content on the page No. 9
RMC 7189 1U Rackmount System CHAPTER 1 INTRODUCTION 1.1 Overview The Acnodes RMC7189 is a high-end single processor, 1U rack- mount server. The RMC7189 is comprised of two main subsystems: the RMC7189 chassis and the embedded board. Please refer to our web site for informa- tion on operating systems that have been certified for use with the RMC7189. In addition to the mainboard and chassis, various hardware components may have been included with the RMC7189, as listed below. o One slim DVD-ROM d
Summary of the content on the page No. 10
RMC 7189 1U Rackmount System 1-2 Serverboard Features At the heart of the Acnodes RMC7189 lies the embedded system, a dual processor serverboard based on the Intel® IOH-36D + ICH10R chipset. Below are the main features of the embedded system (See Figure 1-1 for a block diagram of the chipset). Processor The RMC7189 supports single or dual two Intel® 5500 Series processors in LGA1366 sockets. Please refer to our web site for a complete listing of supported processors Memory The RMC7189 h
Summary of the content on the page No. 11
RMC 7189 1U Rackmount System Other Features Other onboard features that promote system health include voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue. 1-3 Server Chassis Features The RMC7189 features eight 2.5" hard drive bays and high-efficiency power supplies. The RMC7189 is built upon the embedded system chassis while the RMC7189 is built upon the embed- ded system chassis. Details on the
Summary of the content on the page No. 12
RMC 7189 1U Rackmount System Cooling System The RMC7189 chassis' revolutionary cooling design has been optimized to provide sufficient cooling for dual CPU configurations. The chassis includes an air shroud and four 4-cm counter-rotating fans located in the middle of the chassis. There is a "Fan Speed Control Mode" in BIOS that allows chas- sis fan speed to be determined by system temperature. © Copyright 2005 Acnodes, Inc. 661 Brea Canyon Rd., Suite 3 All rights reserved. Product description an
Summary of the content on the page No. 13
RMC 7189 1U Rackmount System CHAPTER 2 INSTALLATION 2-1 Overview This chapter provides a quick setup checklist to get your Acnodes RMC7189 and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your RMC7189 system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a motherboard, processor, system memory etc., please turn to the
Summary of the content on the page No. 14
RMC 7189 1U Rackmount System Rack Precautions o Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. o In a single rack installation, stabilizers should be attached to the rack. o In multiple rack installations, the racks should be coupled together. o Always make sure the rack is stable before extending a component from the rack. o You should extend only one component at a time - extending two or more si- multa
Summary of the content on the page No. 15
RMC 7189 1U Rackmount System Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environ- ment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient tempera- ture (Tmra). Reduced Airflow Equipment should be mounted into a rack so that the amoun
Summary of the content on the page No. 16
RMC 7189 1U Rackmount System 2-4 Installing the System into a Rack This section provides information on installing the Acnodes RMC7189 into a rack. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. Note: This rail will fit a rack between 26" and 33.5" deep. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the RMC7189 into a rack with the rack rails
Summary of the content on the page No. 17
RMC 7189 1U Rackmount System Inner Rails The motherboard chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use a server rack. Attach the inner rail extension to stabilize the chassis within the rack. Installing the Rack Rails 1. Place the inner rack extensions on the side of the chassis aligning the hooks of the chassis with the rail extension ho
Summary of the content on the page No. 18
RMC 7189 1U Rackmount System Outer Rails Installing the Outer Rails to the Rack 1. Attach the short bracket to the outside of the long bracket. You must align the pins with the slides. Also, both bracket ends must face the same direction. 2. Adjust both the short and long brackets to the proper distance so that the rail fits snugly into the rack. 3. Secure the long bracket to the front side of the outer rail with two M5 screws and the short bracket to the rear side of the outer rail with t
Summary of the content on the page No. 19
RMC 7189 1U Rackmount System © Copyright 2009 Acnodes, Inc. 661 Brea Canyon Rd., Suite 3 All rights reserved. Product description and product specifications Walnut, CA 91789 are subject to change without notice. For latest product information, tel: 909.598.7388, fax: 909.598.0218 please visit Acnodes’ web site at www.acnodes.com.
Summary of the content on the page No. 20
RMC 7189 1U Rackmount System Installing the Chassis into a Rack 1. Confirm that chassis includes the inner rails and rail extensions . Also, confirm that the outer rails are installed on the rack. 2. Line chassis rails with the front of the rack rails. 3. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs "cl