Toshiba MMU-AP0071YH user manual

User manual for the device Toshiba MMU-AP0071YH

Device: Toshiba MMU-AP0071YH
Category: Air Conditioner
Manufacturer: Toshiba
Size: 4.09 MB
Added : 11/22/2014
Number of pages: 213
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba MMU-AP0071YH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba MMU-AP0071YH.

For your convenience

If looking through the Toshiba MMU-AP0071YH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba MMU-AP0071YH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba MMU-AP0071YH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba MMU-AP0071YH User manual - Online PDF
Advertisement
« Page 1 of 213 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba MMU-AP0071YH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba MMU-AP0071YH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

 


 
 


  

 

 
    


SUPER MODULAR MULTI SYSTEM AIR CONDITIONER
SMMS CLIMATISEUR
SMMS KLIMAGERÄT
SMMS CONDIZIONATORE D'ARIA
SMMS APARATO DE AIRE ACONDICIONADO
SMMS AR CONDICIONADO
SMMS AIRCONDITIONER


SMMS
For commercial use (Not accessible to the general public)
Indoor Unit
Pour usage commercial (Vente interdite au grand

Summary of the content on the page No. 2

Thank you very much for purchasing TOSHIBA Air Conditioner. ADOPTION OF NEW REFRIGERANT Please read this owner's manual carefully before using your Air Conditioner. This Air Conditioner is a new type which adopts a new  Be sure to obtain the “Owner’s manual” and “Installation manual” from refrigerant HFC (R410A) instead of the conventional constructor (or dealer). refrigerant R22 in order to prevent destruction of the Request to constructor or dealer ozone layer. Please clearly explain the cont

Summary of the content on the page No. 3

CONTENTS Accessory parts and Parts to be procured locally ........................... 1 6 ELECTRIC WORK ....................................................................... 13 1 PRECAUTIONS FOR SAFETY ..................................................... 2 7 APPLICABLE CONTROLS ......................................................... 17 2 SELECTION OF INSTALLATION PLACE ..................................... 4 8 TEST RUN ........................................................................

Summary of the content on the page No. 4

Accessory parts and Parts to be procured locally  Accessory parts Part name Q’ty Shape Usage Installation Manual 1 This manual (Be sure to hand over customers) Heat Insulating pipe 2 For heat insulating of pipe connecting section Installation pattern 1 — For confirmation of ceiling opening and main unit position Pattern fixing screw 5 Installation pattern fixing Refrigerant piping Part name Q’ty Shape Usage  Piping material used for the conventional refrigerant cannot be

Summary of the content on the page No. 5

1 PRECAUTIONS FOR SAFETY  Ensure that all Local, National and International regulations are satisfied.  Read this “PRECAUTIONS FOR SAFETY” carefully before Installation.  The precautions described below include the important items regarding safety. Observe them without fail.  After the installation work, perform a trial operation to check for any problem. Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.  Turn off the main power supply switch (or breake

Summary of the content on the page No. 6

1 PRECAUTIONS FOR SAFETY  After unpacking the unit, examine it carefully if there are possible damage.  Do not install in a place that might increase the vibration of the unit.  To avoid personal injury (with sharp edges), be careful when handling parts.  Perform installation work properly according to the Installation Manual. Inappropriate installation may result in water leakage, electric shock or fire.  When the air conditioner is installed in a small room, provide appropriate measures t

Summary of the content on the page No. 7

2 SELECTION OF INSTALLATION PLACE WARNING  Install the air conditioner at enough strong place to withstand the weight of the unit. If the strength is not enough, the unit may fall down resulting in injury.  Perform a specified installation work to guard against an earth quake. An incomplete installation can cause accidents by the units failing and dropping.  Install the air conditioner at a height 2.5m or more from the floor. If you insert your hands or others directly into the unit while t

Summary of the content on the page No. 8

8m or less 2 SELECTION OF INSTALLATION PLACE Removal of transporting rubbers In case of wireless type  Before installation of the indoor unit, remove the two The sensor of indoor unit with wireless remote protective rubbers for transportation which are controller can receive a signal within approx. 8m. inserted between the reinforcing bracket for the fan Based upon it, determine a place where the remote motor and the casing. controller is operated and the installation place of the (Hand over th

Summary of the content on the page No. 9

External view Panel external dimension 1050 Ceiling open dimension 20 20 1010 890 395 455 Power connecting port Center of panel 850 50 110 Drain pipe connecting port (VP25) Hanging bolt 4-M10 Arranged at site 150 400 850 225 100 Support metal Ceiling panel Ceiling Refrigerant pipe connecting port (Sold separately) bottom surface (Gas side Ø9.5) Refrigerant pipe connecting port (Liquid side Ø6.4) Discharge louver Discharge port 1050 Panel mounting hole 5 positions Air suction grille Space nece

Summary of the content on the page No. 10

3 INSTALLATION OF INDOOR UNIT Ceiling opening and installation of hanging bolts  Considering pipe/wire connecting work inside the ceiling after the indoor unit has been hanged, select an installation place and determine piping direction.  After installation place of the indoor unit has been determined, open the installation hole on the ceiling and install the hanging bolts.  For the ceiling opening size and the hanging bolt pitch, refer to the external view and the attached installation patte

Summary of the content on the page No. 11

Installation of indoor unit CAUTION This unit is incorporated with drain pump and float switch. Never incline the main unit. Otherwise, malfunction of the float switch may be caused resulting in water leakage.  Attach the nut (M10 or W3/8: Procured locally) and the attached washer (Ø34mm) to the hanging bolt.  Adjust nut position (lower side) so that clearance between (lower side) and the lower side of ceiling board is 137mm.  Hang up the main unit by hanging nut of hanging bolt to T groo

Summary of the content on the page No. 12

4 DRAIN PIPING WORK Pipe material/Insulator and size CAUTION The following materials for piping work and insulating  Following the Installation Manual, process are procured locally. perform the drain piping work so that water is properly drained, and apply a Hard vinyl chloride pipe VP25 Pipe material heat insulation so as not to cause a dew. (Outer diameter Ø32mm) Inappropriate piping work may result in water leakage in the room and wet of Foamed polyethylene foam, thickness: Insulator 10mm

Summary of the content on the page No. 13

Check the draining After drain piping work, check that water drain is Air outlet properly performed and water does not leak from the connecting part of the pipes. In this time, check also there is no abnormal sound of the motor of the drain pump. Be sure to check draining when installed in the heating period. Pitcher When the electric work has finished:  Before installing a panel, pour water (500cc) as shown in the following figure, check water is drained from the drain pipe connecting port in

Summary of the content on the page No. 14

5 REFRIGERANT PIPING WARNING  If refrigerant gas has leaked during the installation work, ventilate the room immediately.  If the leaked refrigerant gas comes in contact with fire, noxious gas may generate.  After the installation work, confirm that refrigerant gas does not leak.  If refrigerant gas leaks into the room and flows near a fire source, such as a cooking range, noxious gas may generate. REQUIREMENT When the refrigerant pipe is long, set the support brackets to fix the pipe with

Summary of the content on the page No. 15

 Projection margin in flaring : B (Unit : mm) Airtight test/Air purge, etc. Rigid (Clutch type) For airtight test, air purge, addition of refrigerant, and R410A tool used Conventional tool used gas leak check, follow the Installation Manual attached Outer diam. of to the outdoor unit. copper pipe R410A R22 R410A R22 REQUIREMENT 6.4 0 to 0.5 (Same as left) 1.0 to 1.5 0.5 to 1.0 Be sure to use the tool such as charge hose 9.5 0 to 0.5 (Same as left) 1.0 to 1.5 0.5 to 1.0 exclusive to R410A. 1

Summary of the content on the page No. 16

6 ELECTRIC WORK WARNING 1. Using the specified wires, ensure to connect the wires, and fix wires securely so that the external strength of the wires do not transmit to the connecting part of the terminals. Incomplete connection or fixation may cause a fire, etc. 2. Be sure to connect earth wire. (Grounding work) Do not connect the earth wire to gas pipe, city water pipe, lightning rod, or the earth wire of telephone. Incomplete grounding causes an electric shock. 3. For electric work, strictl

Summary of the content on the page No. 17

Power supply specifications Power supply cord and communication wires are procured locally. For the power supply specifications, follow to the table below. If capacity is little, it is dangerous because overheat or seizure may be caused. For specifications of the power capacity of the outdoor unit and the power supply wires, refer to the Installation Manual attached to the outdoor unit. 220–240V ~ 50Hz Power supply 220V ~ 60Hz Power supply switch/Earth leakage breaker or power supply wi

Summary of the content on the page No. 18

6 ELECTRIC WORK Cable connection REQUIREMENT • As the remote controller cable has no polarity, there is no problem if connections to indoor unit terminal blocks A and B are reversed. • Be sure to pass the cable through the bushing of cable connection port of the indoor unit. • Keep a margin (approx. 100m) on a cable to hang down the electric parts box at servicing, etc. • The low-voltage circuit is provided for the remote controller. (Do not connect high-voltage circuit.) How to remove cover of

Summary of the content on the page No. 19

Remote controller wiring • Strip off approx. 14mm cover of the wire to be connected.  Twist wire of the remote controller to be connected with wire of the remote controller unit (or sensor), and press-fit them with a wire joint. (Wire joints (White: 2 pieces) are included in the accessory of the main remote controller (sold separately) or wireless remote controller kit (sold separately).)  As the remote controller wire has no polarity, there is no problem if connections to indoor unit terminal

Summary of the content on the page No. 20

7 APPLICABLE CONTROLS NOTIFICATION When using the equipment at the first time, it will take a lot of time that the remote controller accepts an operation after power was on. However, it is not a trouble.  Automatic address • While automatic addressing, the operation cannot be performed on the remote controller. • For automatic addressing, Max. 10 minutes (generally, approx. 5 minutes) are required.  When power will be turned on after finish of automatic addressing; • It will require Max. 10 mi


Alternative user manuals
# User manual Category Download
1 Toshiba CARRIER RAS-15LAV-UL User manual Air Conditioner 228
2 Toshiba CARRIER RAS-17LAV-UL User manual Air Conditioner 25
3 Toshiba CARRIER RAS-17LKV-UL User manual Air Conditioner 79
4 Toshiba CARRIER RAS-22LKV-UL User manual Air Conditioner 53
5 Toshiba CARRIER RAV-SP180UT-UL User manual Air Conditioner 29
6 Toshiba CARRIER RAS-15LKV-UL User manual Air Conditioner 84
7 Toshiba CARRIER RAV-SP180CT-UL User manual Air Conditioner 10
8 Toshiba CARRIER RAV-SP240CT-UL User manual Air Conditioner 3
9 Toshiba CARRIER RAS-22LAV-UL User manual Air Conditioner 4
10 Toshiba CARRIER RAV-SP180AT2-UL User manual Air Conditioner 8
11 Toshiba CARRIER RAV-SP240AT2-UL User manual Air Conditioner 11
12 Toshiba CARRIER RAV-SP300AT2-UL User manual Air Conditioner 6
13 Toshiba CARRIER RAV-SP240UT-UL User manual Air Conditioner 3
14 Toshiba CARRIER RAV-SP300CT-UL User manual Air Conditioner 3
15 Toshiba CARRIER RAV-SP360AT2-UL User manual Air Conditioner 3
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21