Toshiba RAV-SM561BT-E user manual

User manual for the device Toshiba RAV-SM561BT-E

Device: Toshiba RAV-SM561BT-E
Category: Air Conditioner
Manufacturer: Toshiba
Size: 2.88 MB
Added : 10/23/2013
Number of pages: 126
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba RAV-SM561BT-E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba RAV-SM561BT-E.

For your convenience

If looking through the Toshiba RAV-SM561BT-E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba RAV-SM561BT-E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba RAV-SM561BT-E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba RAV-SM561BT-E User manual - Online PDF
Advertisement
« Page 1 of 126 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba RAV-SM561BT-E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba RAV-SM561BT-E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





  

RAV-SM561BT-E/RAV-SM560AT-E
RAV-SM801BT-E/RAV-SM800AT-E
RAV-SM1101BT-E/RAV-SM1100AT-E
RAV-SM1401BT-E/RAV-SM1400AT-E
R410A
PRINTED IN JAPAN, Feb.,2004 ToMo

Summary of the content on the page No. 2

CONTENTS 1. SPECIFICATIONS ................................................................................................ 1 2. AIR DUCTING WORK .......................................................................................... 7 3. CONSTRUCTION VIEWS (EXTERNAL VIEWS) ................................................. 9 4. SYSTEMATIC REFRIGERATING CYCLE DIAGRAM ....................................... 13 5. WIRING DIAGRAM ...................................................................

Summary of the content on the page No. 3

1. SPECIFICATIONS 1-1. Indoor Unit Concealed Duct Type Model name RAV-SM561BT-E RAV-SM801BT-E Cooling Heating Average Cooling Heating Average Standard capacity (Note 1) (kW) 5.0 5.6 7.1 8.0 (1.5 – 5.6) (1.5 – 6.3) (2.2 – 8.0) (2.2 – 9.0) Heating low temp. capacity (Note 1) (kW) 4.6 6.2 Energy consumption effect ratio (Cooling) 2.81 [C] 3.27 [C] 3.04 2.81 [C] 3.32 [C] 3.07 Power supply 1 phase 230V (220 – 240V) 50Hz Running current (A) 8.99–8.24 8.18–7.50 12.25–11.21 11.65–10.68 Electrical Power

Summary of the content on the page No. 4

Model name RAV-SM1101BT-E RAV-SM1401BT-E Cooling Heating Average Cooling Heating Average Standard capacity (Note 1) (kW) 10.0 11.2 12.5 14.0 (2.2 – 11.2) (2.2 – 12.5) (3.0 – 13.2) (3.0 – 16.0) Heating low temp. capacity (Note 1) (kW) 8.7 11.8 Energy consumption effect ratio (Cooling) 2.81 [C] 3.57 [B] 3.19 2.83 [C] 3.47 [B] 3.15 Power supply 1 phase 230V (220 – 240V) 50Hz Running current (A) 16.5–15.1 14.6–13.4 20.7–19.0 18.9–17.3 Electrical Power consumption (kW) 3.56 3.14 4.42 4.03 characteris

Summary of the content on the page No. 5

1-2. Outdoor Unit Model name RAV-SM560AT-E RAV-SM800AT-E Appearance Silky shade (Muncel 1Y8.5/0.5) 1 phase 230V (220 – 240V) 50Hz Power supply (Power exclusive to outdoor is required.) Type Hermetic compressor Compressor Motor (kW) 1.1 1.6 Pole 8 poles Refrigerant charged (kg) R410A 0.9 R410A 1.5 Refrigerant control Pulse motor valve Standard length 20 (without additional charge) Max. total length (m) 30 50 Pipe Over 20m Add 20g/m (Max. 200g) Add 40g/m (Max. 1200g) Outdoor lower (m) 30 Height di

Summary of the content on the page No. 6

Model name RAV-SM1100AT-E RAV-SM1400AT-E Appearance Silky shade (Muncel 1Y8.5/0.5) 1 phase 230V (220 – 240V) 50Hz Power supply (Power exclusive to outdoor is required.) Type Hermetic compressor Compressor Motor (kW) 2.0 3.75 Pole 8 poles Refrigerant charged (kg) R410A 2.1 R410A 2.3 Refrigerant control Pulse motor valve Standard length 20 (without additional charge) Max. total length (m) 50 Pipe Over 20m Add 40g/m (Max. 1200g) Outdoor lower (m) 15 Height difference Outdoor higher (m) 30 Height (m

Summary of the content on the page No. 7

1-3. Operation Characteristic Curve RAV-SM561BT-E / SM801BT-E 14 16 14 12 RAV-SM801BT-E RAV-SM801BT-E 12 10 10 8 8 6 6 RAV-SM561BT-E 4 RAV-SM561BT-E 4 • Conditions  Conditions Indoor : DB27˚C/WB19˚C Indoor : DB20˚C 2 Outdoor : DB7˚C/WB6˚C Outdoor : DB35˚C 2 Air flow : High Air flow : High Pipe length : 7.5m Pipe length : 7.5m 220V 220V 0 0 15 15 020 40 60 70 80 100 020 40 60 80 90 100 Compressor speed (rps) Compressor speed (rps) RAV-SM1101BT-E 20 20 18 1

Summary of the content on the page No. 8

RAV-SM1401BT-E 22 22 20 20 18 18 RAV-SM1401BT-E RAV-SM1400UT-E RAV-SM1400UT-E RAV-SM1401BT-E 16 16 14 14 12 12 10 10 8 8 6 6  Conditions  Conditions Indoor : DB27˚C/WB19˚C Indoor : DB20˚C 4 4 Outdoor : DB35˚C Outdoor : DB7˚C/WB6˚C Air flow : High Air flow : High Pipe length : 7.5m Pipe length : 7.5m 2 2 230V 230V 0 0 020 40 60 80 020 40 60 80 Compressor speed (rps) Compressor speed (rps) 1-4. Capacity Variation Ratio According to Temperature 120 105 110

Summary of the content on the page No. 9

High static pressure 1H tap Standard H tap Low static pressure H tap Standard L tap High static pressure 1H tap Standard H tap Low static pressure H tap Standard L tap High static pressure 2H tap High static pressure 2H tap High static pressure 1H tap Standard L tap High static pressure 2H tap Low static pressure H tap Low static pressure H tap Standard L tap Standard H tap High static pressure 1H tap High static pressure 2H tap Standard H tap 2. AIR DUCTING WORK 2-1. Static Pressure Characteri

Summary of the content on the page No. 10

High static pressure 2H tap High static pressure 1H tap Standard H tap Low static pressure H tap Standard L tap Standard H tap Low static pressure H tap Low static pressure H tap High static pressure 2H tap Standard H tap High static pressure 1H tap Standard L tap High static pressure 1H tap High static pressure 2H tap Standard L tap Standard L tap Low static pressure H tap High static pressure 2H tap High static pressure 1H tap Standard H tap Fig. 5 RAV-SM1101BT-E (Round duct) Fig. 7 RAV-SM14

Summary of the content on the page No. 11

3. CONSTRUCTION VIEWS (EXTERNAL VIEWS) 3-1. Indoor Unit 3-1-1. Concealed Duct Type RAV-SM561BT-E / SM801BT-E / SM1101BT-E / SM1401BT-E Refrigerant pipe connecting port Drain pipe connecting port (Gas side ØF) for vinyl chloride pipe (Inner dia. 32, VP. 25) Hanging bolt 4-M10 screw Discharge port flange (Arranged locally) N-Ø200 75 Main unit dimension 800 Hanging bolt pitch B 41 Hanging bolt pitch 700 59 Main unit dimension A 50 638 J = M x K H 129 498 Knock-out hole Ø125 (Air take-in port)

Summary of the content on the page No. 12

3-2. Outdoor Unit RAV-SM560AT-E Drain hole (2-Ø20 x 88 long hole) Drain hole (Ø25) 83 600 97 A legs 115.3 125 30 780 B legs Discharge guide mounting hole 115.3 216 49.5 147 (4-Ø4 Embossing) Discharge guard Valve cover 31 23 25 220 500 (Fan center dividing) Charge port 31 134 Protective net mounting hole (2-Ø4 Embossing) 43 707 30 Protective net mounting hole (4-Ø4 Embossing) Refrigerant pipe connecting port Refrigerant pipe connecting port (Ø12.7 Flare at gas side) (Ø6.4 Flare at liquid side)

Summary of the content on the page No. 13

RAV-SM800AT-E Knockout (For draining) Drain hole (Ø20 x 88 Burring hole) Drain hole (Ø25 Burring hole) Installation bolt hole 29 90 191 20 (Ø12 x 17 U-shape holes) Suction Part B port Suction Details of B part Knockout port (For draining) Details of A part Discharge 43 26 60 port Part A 95 150 300 Installation bolt hole (Ø12 x 17 U-shape holes) 900 314 Handles (Both sides) Refrigerant pipe connecting port (Ø9.5 Flare at liquid side) Refrigerant pipe connecting port (Ø15.9 Flare at gas side)

Summary of the content on the page No. 14

RAV-SM1100AT-E / SM1400AT-E Knockout (Drain) Drain hole (Ø20 x 88) 29 90 191 20 Suction Drain hole (Ø25) port B legs A legs Suction port Knockout (Drain) Discharge port 26 60 43 600 108 50 320 900 Refrigerant pipe connecting port (Ø9.5 Flare at liquid side) Refrigerant pipe connecting port (Ø15.9 Flare at gas side) 28 60 27 27 58 z 95 161 314 307 400 Mounting bolt hole Mounting bolt hole (Ø12 x 17 Long hole) (Ø12 x 17 U-shape hole) 12 Details of A legs Details of B legs 86 7 46 Z view Spac

Summary of the content on the page No. 15

4. SYSTEMATIC REFRIGERATING CYCLE DIAGRAM 4-1. Indoor Unit/Outdoor Unit RAV-SM561BT-E Indoor unit TCJ sensor Air heat exchanger TC sensor Outer diameter of refrigerant pipe Gas side ØA Liquid side ØB 12.7mm 6.4mm Refrigerant pipe Refrigerant pipe at gas side at liquid side Outer dia. ØA Outer dia. ØB Max. 30m Pd Packed valve Packed valve Ps Outer dia. ØA Outer dia. ØB Outdoor unit PMV TS sensor (SKV-18D26) TO sensor TD sensor Strainer 4-way valve TE (VT7101D) sensor Heat exchanger Muffler Ø8

Summary of the content on the page No. 16

RAV-SM801BT-E Indoor unit TCJ sensor Air heat exchanger TC sensor Outer diameter of refrigerant pipe Gas side ØA Liquid side ØB 15.9mm 9.5mm Refrigerant pipe Refrigerant pipe at gas side at liquid side Outer dia. ØA Outer dia. ØB Max. 50m Pd Ps Packed valve Packed valve Outer dia. ØA Outer dia. ØB Outdoor unit Modulating (PMV) Strainer TS sensor (SKV-18D26) TO sensor TD sensor Strainer TE 4-way valve sensor (STF-0213Z) Capillary Muffler Accumulator Ø3×Ø2× (1500cc) Heat exchanger Ø8 Ø25 × L210

Summary of the content on the page No. 17

RAV-SM1001BT-E Indoor unit Distributor TCJ sensor (Strainer incorporated) Outer diameter of refrigerant pipe Strainer Gas side ØA Liquid side ØB Air heat exchanger 15.9mm 9.5mm TC sensor Refrigerant pipe Refrigerant pipe at gas side at liquid side Outer dia. ØA Outer dia. ØB Max. 50m Ball valve Packed valve Outer dia. ØA Outer dia. ØB Outdoor unit Strainer PMV TS sensor Check joint (UKV-25D22) TO sensor TD sensor Strainer TE sensor 4-way valve (STF-0213Z) Heat exchanger Ø8 Muffler Distributor

Summary of the content on the page No. 18

RAV-SM1401BT-E Indoor unit Distributor TCJ sensor (Strainer incorporated) Outer diameter of refrigerant pipe Strainer Gas side ØA Liquid side ØB Air heat exchanger 15.9mm 9.5mm TC sensor Refrigerant pipe Refrigerant pipe at gas side at liquid side Outer dia. ØA Outer dia. ØB Max. 50m Ball valve Packed valve Outer dia. ØA Outer dia. ØB Outdoor unit Strainer PMV TS sensor Check joint (UKV-25D22) TO sensor TD sensor Strainer TE sensor 4-way valve (STF-0213Z) Heat exchanger Ø8 Muffler Distributor

Summary of the content on the page No. 19

5. WIRING DIAGRAM 5-1. Indoor Unit RAV-SM561BT-E / SM801BT-E / SM1101BT-E / SM1401BT-E TA TCJ TC (EXCT) 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 1 2 1 2 CN104 CN102 CN101 CN80 CN73 CN70 (YEL) (RED) (BLK) (GRN) (RED) (WHI) 5 CN34 4 CN620 FS (RED) MCC-1402 3 (BLU) 3 3 2 1 2 2 Control P.C. Board for 1 1 6 Indoor Unit 5 CN60 4 CN33 (WHI) 3 (WHI) DC20V 2 DC15V 5 1 DC12V 4 DC7V CN32 3 2 (WHI) Power 2 1 1 supply (FAN DRIVE) circuit 6 Fuse 5 F302 4 CN61 T3.15A CN333 (YEL) 3 (WHI) 250V~ 2 5 5 1 4 4 Motor 3 3 dri

Summary of the content on the page No. 20

+ + + 5-2. Outdoor Unit RAV-SM560AT-E REACTOR Q200 DB01 THERMOSTAT CONVERTER FOR IGBT MODULE MODULE COMPRESSOR BRW ORN 2 1 BLU CN500 2 1 2 1 ~ ~ + – A E G P10 P09 2 1 TE P20 P19 P17 P18 P08 P07 1 1 CN600 2 2 TD 1 1 ELECTRONIC CN601 2 2 CT STARTER 3 3 POWER TO RELAY 1 1 CN602 P.C. BOARD 2 2 3 2 1 (MCC-813) TS 4 3 2 1 1 1 – C12 CN603 2 2 – 3 C13 3 3 – RELAY C14 Q300 CM 1 1 CN701 2 2 COMPRESSOR 3 3 COIL FOR 4-WAY VALVE P06 BLK SURGE F04 ABSORBER FUSE 2 T3. 15A BLK 1 1 250V~ YEL 2 2 VARISTOR RED 3 3


Alternative user manuals
# User manual Category Download
1 Toshiba CARRIER RAS-15LAV-UL User manual Air Conditioner 228
2 Toshiba CARRIER RAS-17LAV-UL User manual Air Conditioner 25
3 Toshiba CARRIER RAS-17LKV-UL User manual Air Conditioner 79
4 Toshiba CARRIER RAS-22LKV-UL User manual Air Conditioner 53
5 Toshiba CARRIER RAV-SP180UT-UL User manual Air Conditioner 29
6 Toshiba CARRIER RAS-15LKV-UL User manual Air Conditioner 84
7 Toshiba CARRIER RAV-SP180CT-UL User manual Air Conditioner 10
8 Toshiba CARRIER RAV-SP240CT-UL User manual Air Conditioner 3
9 Toshiba CARRIER RAS-22LAV-UL User manual Air Conditioner 4
10 Toshiba CARRIER RAV-SP180AT2-UL User manual Air Conditioner 8
11 Toshiba CARRIER RAV-SP240AT2-UL User manual Air Conditioner 11
12 Toshiba CARRIER RAV-SP300AT2-UL User manual Air Conditioner 6
13 Toshiba CARRIER RAV-SP240UT-UL User manual Air Conditioner 3
14 Toshiba CARRIER RAV-SP300CT-UL User manual Air Conditioner 3
15 Toshiba CARRIER RAV-SP360AT2-UL User manual Air Conditioner 3
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21