Teledyne 3160 user manual

User manual for the device Teledyne 3160

Device: Teledyne 3160
Category: Computer Drive
Manufacturer: Teledyne
Size: 2.59 MB
Added : 8/19/2014
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 3160. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 3160.

For your convenience

If looking through the Teledyne 3160 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 3160 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 3160 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 3160 User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 3160 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 3160. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING INSTRUCTIONS FOR
Model 3160
Trace Oxygen Analyzer
DANGER
HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.
PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.
HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST FOR A
TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.
ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE
CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH

Summary of the content on the page No. 2

Copyright © 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580. Warranty This equi

Summary of the content on the page No. 3

TELEDYNE ANALYTICAL INSTRUMENTS iii

Summary of the content on the page No. 4

T T Tab ab able of Contents le of Contents le of Contents T Tab able of Contents le of Contents 1 Introduction 1.1 Features ....................................................................................... 1-1 1.1.1 Fixed Features .............................................................. 1-1 1.1.2 Variable Features ......................................................... 1-1 1.2 Components ................................................................................. 1-3 1.3 Opt

Summary of the content on the page No. 5

T T Tab ab able of Contents (contin le of Contents (contin le of Contents (continued) ued) ued) T Tab able of Contents (contin le of Contents (continued) ued) Calibration Zeroing ........................................................... 4-6 Calibration Using Span Gas .............................................. 4-8 Select Active Sensor (Two Cells Only) ............................. 4-11 Install Sensor and Test Alternate Sensor .... (Two Cells Only) .. 4-12 O Range Set-Up ....................

Summary of the content on the page No. 6

TELEDYNE ANALYTICAL INSTRUMENTS vi

Summary of the content on the page No. 7

Introduction 1 Introduction 1 Introduction 1 Introduction 1 Introduction 1 Introduction 1.1 Features 1.1.1 Fixed Features The Model 3160 is a microprocessor-based trace oxygen monitoring system that provides on-line monitoring of trace oxygen at parts-per-million (PPM) levels and can directly measure the level of purity in high-grade gases. ® The 3160 computer uses an Intel 80188 microprocessor combined with 32 kilobytes of random access memory (RAM) and 128 kilobytes of read-only memory (R

Summary of the content on the page No. 8

1 Introduction 1 Introduction 1 Introduction 1 Introduction 1 Introduction The 3160 features six full-scale linear ranges of analysis:  0–1 PPM  0–10 PPM  0–100 PPM  0–1000 PPM  0–1%  0–25% An AutoRanging feature automatically selects the range that is appropriate for a given reading. For example, if the O level exceeds 100% of the current range, the 2 analyzer switches to the next higher range. When desired, a manual override feature allows a particular range of interest to be locked

Summary of the content on the page No. 9

Introduction 1 Introduction 1 Introduction 1 Introduction 1 Introduction 1 1.2 Components The analyzer is designed to mount in a standard 19-inch rack. All of the opera- tional controls are easily accessed through the front panel. The analyzer contains each of the following:  Analysis Section  Single or Dual Electrochemical Micro-Fuel Cell  Sample System  Power Supply  Microcontroller Module  LED Display The front panel consists of:  LED Display  LCD Display with Touch Panel  Micr

Summary of the content on the page No. 10

1 Introduction 1 Introduction 1 Introduction 1 Introduction 1 Introduction 1.4 Applications The analyzer is an invaluable tool in the following applications and industries:  Inert and gaseous hydrocarbon stream monitoring.  Measuring the purity of various gases in air separation plants.  Prevention of oxidation by measuring the purity of blanketing gases in fiber and glass industries.  Monitoring and controlling gas atmospheres in the heat treatment of metals in steel and other metal in

Summary of the content on the page No. 11

Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2.1 Principles of Operation The sub-systems that make up the analyzer are: 1. Micro-Fuel Cell Sensor 2. Sample System 3. Electronic Signal Processing The Micro-Fuel Cell sensor is an electrochemical galvanic device that translates the amount of oxygen present in the sample into an electrical current. The sample system delivers the sample gas in a form that is as unalte

Summary of the content on the page No. 12

2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory I O Figure 2-1. Major Components. TELEDYNE ANALYTICAL INSTRUMENTS 2-2

Summary of the content on the page No. 13

Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 2.1.1 Micro-Fuel Cell Sensor The Micro-Fuel Cell is a sealed plastic disposable oxygen transducer that mea- sures 1¼ inches in diameter and is ¾ inch thick. Inside of the cell are a cathode and anode immersed in 15% aqueous KOH electrolyte. At one end of the sensor is a Teflon diffusion membrane; the other end is sealed with a polyethylene membrane. At the rear of the cell is a contact p

Summary of the content on the page No. 14

2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory  Electropolished 316L-type stainless steel components. To eliminate oxygen absorption and desorption from the internal wetted surfaces of the sample system components, the sample system is fabricated from electropolished 316L-type stainless steel.  Welding/Metal Gasket-Type Fittings. All of the joints upstream of the Micro-Fuel Cell oxygen sensor are orbitally welded. Orbital welding i

Summary of the content on the page No. 15

Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 to be used to zero the analyzer, eliminating the need to switch external tanks.  Overall Design. The design of the sample system minimizes the volume of dead space, which can retain residual gas from another route or previous mode of analysis. Figure 2-2: Model 3160 flow schematic. 2.1.3 Electronics and Signal Processing The Model 3160 analyzer has an embedded microcomputer, which cont

Summary of the content on the page No. 16

2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory Electronics in the analyzer are grouped according to function: 1. Analog in 2. Analog out 3. Digital circuit 4. Power supply Analog signal processing is accomplished in two plug-in circuit cards operating under control of the microcomputer. All analog signals are converted to digital early in the processing cycle to minimize analog processing and assure maximum system accuracy, since dig

Summary of the content on the page No. 17

Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 The analog output printed circuit board (PCB) generates the two 0–1 volt and the two 4–20 mA analog signal outputs available on the rear panel of the analyzer. These signals, generated in digital format by the microcomputer, are converted into analog signals by the circuitry on this PCB. The output signals represent the following:  0–1V Signal (Oxygen Measurement): This output goes from

Summary of the content on the page No. 18

2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory 2 Operational Theory The digital printed circuit board (PCB) is a general purpose microcomputer used to control all functions of the analyzer. The analog input PCB and the analog output PCB plug directly into connectors located on the digital PCB. In addition to control- ling these analog PCBs, the digital board performs the following functions: 1. Processes input from the control panel pushbuttons. 2. Provi

Summary of the content on the page No. 19

Installation 3 Installation 3 Installation 3 Installation 3 Installation 3 Installation Installation of the analyzer includes: 1. Unpacking the system. 2. Recognizing the necessary precautions when installing the system. 3. Hooking up the sample/span gas and air supply to appropriate connections. 4. Installing the Micro-Fuel Cell sensor(s). 5. Hooking up electrical connections. 6. Testing the system. 3.1 Unpacking the Analyzer The analyzer is shipped with all the materials and special items

Summary of the content on the page No. 20

3 Installation 3 Installation 3 Installation 3 Installation 3 Installation 3. Parts Per Million (PPM) and Percent Oxygen indicators: the PPM light will light while the instrument is measuring O in units of PPM. The percent 2 light will light while the instrument is measuring O concentration in 2 percent. 4. Flow Indicator and Flow Set: a flowmeter and flow set knob are provided for adjusting gas flow in standard cubic feet per hour (SCFH). 5. Liquid Crystal Display (LCD) with keypad: the L


Alternative user manuals
# User manual Category Download
1 Sony MSH-128S2 User manual Computer Drive 2
2 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
3 Sony SAITE1300-F User manual Computer Drive 0
4 Sony CRX - 160E User manual Computer Drive 0
5 Sony 2GN User manual Computer Drive 0
6 Sony 7819900133 User manual Computer Drive 0
7 Sony USM512U2 User manual Computer Drive 0
8 Sony DRX-S70U-W User manual Computer Drive 22
9 Sony BDX-S500U User manual Computer Drive 29
10 Sony 500gb External Hard Disk Drive HDEG5/B User manual Computer Drive 1
11 Sony VAIO VPCSB User manual Computer Drive 39
12 Sony 500gb External Hard Disk Drive HDEG5B User manual Computer Drive 2
13 Sony 2-586-675-11 (1) User manual Computer Drive 0
14 Sony BW-RU101 User manual Computer Drive 5
15 Sony CRX10U User manual Computer Drive 0