National Instruments NI USB-6008/6009 user manual

User manual for the device National Instruments NI USB-6008/6009

Device: National Instruments NI USB-6008/6009
Category: Computer Drive
Manufacturer: National Instruments
Size: 0.86 MB
Added : 1/19/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI USB-6008/6009. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI USB-6008/6009.

For your convenience

If looking through the National Instruments NI USB-6008/6009 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI USB-6008/6009 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI USB-6008/6009 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI USB-6008/6009 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI USB-6008/6009 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI USB-6008/6009. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER GUIDE AND SPECIFICATIONS
NI USB-6008/6009
Français Deutsch
ni.com/manuals
This user guide describes how to use the National Instruments
USB-6008/6009 data acquisition (DAQ) devices and lists specifications.
Introduction
The NI USB-6008/6009 provides connection to eight analog input (AI)
channels, two analog output (AO) channels, 12 digital input/output (DIO)
channels, and a 32-bit counter with a Full-Speed USB interface.
Note This manual revision updates naming conventions to reflect the

Summary of the content on the page No. 2

1 Analog 16 Table 2. Differences Between the NI USB-6008 and NI USB-6009 Feature NI USB-6008 NI USB-6009 AI Resolution 12 bits differential, 14 bits differential, 11 bits single-ended 13 bits single-ended Maximum AI Sample Rate, 10 kS/s 48 kS/s * Single Channel Maximum AI Sample Rate, 10 kS/s 48 kS/s * Multiple Channels (Aggregate) DIO Configuration Open collector Open collector or active drive * System dependent. 1 NI USB-6009 8 Inputs, 14-bit, Multifunction I/O 1 USB Cable Strain Relief Figu

Summary of the content on the page No. 3

Dimensions Figure 3 illustrates the dimensions of the NI USB-6008/6009 device. 23.19 mm 81.81 mm (0.913 in.) (3.221 in.) 85.09 mm (3.350 in.) NATIONAL INSTRUMENTS 76.09 mm (2.996 in.) 63.50 mm (2.500 in.) 72.65 mm (2.860 in.) Figure 3. NI USB-6008/6009 in Millimeters (Inches) Safety Guidelines Caution Operate the NI USB-6008/6009 only as described in these operating instructions. The following section contains important safety information that you must follow when installing and using the

Summary of the content on the page No. 4

Caution Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. If you must operate the device in such an environment, it must be in a suitably rated enclosure. If you need to clean the device, use a dry cloth. Make sure that the device is completely dry and free from contaminants before returning it to service. Operate the device only at or below Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce

Summary of the content on the page No. 5

� Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet (for example, 115 V for U.S. or 230 V for Europe). Examples of Measurement Category II are measurements performed on household appliances, portable tools, and similar E Series devices. � Measurement Category III is for measurements performed in the building

Summary of the content on the page No. 6

LabVIEW If you are a new user, use the Getting Started with LabVIEW manual to familiarize yourself with the LabVIEW graphical programming environment and the basic LabVIEW features you use to build data acquisition and instrument control applications. Open the Getting Started with LabVIEW manual by selecting Start»All Programs»National Instruments»LabVIEW»LabVIEW Manuals or by navigating to the labview\manuals directory and opening LV_Getting_Started.pdf. Use the LabVIEW Help, available by

Summary of the content on the page No. 7

can create channels and tasks, and write your own applications in your ADE using the NI-DAQmx API. For help with NI-DAQmx methods and properties, refer to the NI-DAQmx .NET Class Library or the NI-DAQmx Visual C++ Class Library included in the NI Measurement Studio Help. For general help with programming in Measurement Studio, refer to the NI Measurement Studio Help, which is integrated with the Microsoft Visual Studio .NET help. To view this help file in Visual Studio. NET, select Measure

Summary of the content on the page No. 8

Library»Using the Measurement Studio .NET Class Libraries to view conceptual topics for using NI-DAQmx with Visual C# and Visual Basic .NET. To get to the same help topics from within Visual Studio, go to Help»Contents. Select Measurement Studio from the Filtered By drop-down list and follow the previous instructions. Device Documentation and Specifications Documentation for supported devices and accessories, including PDF and help files describing device terminals, specifications, features

Summary of the content on the page No. 9

Note All NI-DAQmx Base documentation for Mac OS X is installed at /Applications/National Instruments/NI-DAQmx Base/documentation. Training Courses If you need more help getting started developing an application with NI products, NI offers training courses. To enroll in a course or obtain a detailed course outline, refer to ni.com/training. Technical Support on the Web For additional support, refer to ni.com/support or zone.ni.com. Installing the Software Software support for the NI USB-6008/6

Summary of the content on the page No. 10

Installing the NI USB-6008/6009 Device Before installing the device, you must install the software you plan to use with the device. Refer to the Installing the Software section of this guide and the documentation included with the software for more information. Figure 4 shows key functional components of the NI USB-6008/6009. External Vbus Power +5 V/200 mA Supply PFI 0 USB USB Microcontroller P1.<0..3> P0.<0..7> +2.5 V/CAL 8 Channel 12/14b ADC AI <0..7> 12b DAC AO 0 12b DAC AO 1 Figure

Summary of the content on the page No. 11

1 Analog 16 2. Figure 5 illustrates the signal labels that ship in the NI USB-6008/6009 kit. You can apply the signal labels to the screw terminal blocks for easy signal identification. 3 or 4 ANALOG DIGITAL 1 2 1 Terminal Number Labels (Use Both Together) 3 Differential Signal Name Label (Use Either) 2 Digital I/O Label 4 Single-Ended Signal Name Label (Use Either) Figure 5. NI USB-6008/6009 Signal Labels 3. Refer to Table 4 and Figures 5 and 6 for signal label orientation and affix the pro

Summary of the content on the page No. 12

Note Once you label the screw terminal blocks, you must only insert them into the matching combicon jack, as indicated by the overlay label on the NI USB-6008/6009 device. 4. Connect the wiring to the appropriate screw terminals. Connecting the NI USB-6008/6009 to a Computer Plug one end of the USB cable into the NI USB-6008/6009 and the other end into an available USB port on the computer. LED Indicator The NI USB-6008/6009 device has a green LED next to the USB connector. The LED indicator

Summary of the content on the page No. 13

1234567 8 9 10111213141516 Table 4 lists the analog terminal assignments, and Table 5 lists the digital terminal assignments. Table 4. Analog Terminal Assignments Signal, Signal, Module Terminal Single-Ended Mode Differential Mode 1 GND GND 2 AI 0 AI 0+ 3 AI 4 AI 0– 4 GND GND 5 AI 1 AI 1+ 6 AI 5 AI 1– 7 GND GND 8 AI 2 AI 2+ 9 AI 6 AI 2– 10 GND GND 11 AI 3 AI 3+ 12 AI 7 AI 3– 13 GND GND 14 AO 0 AO 0 15 AO 1 AO 1 16 GND GND © National Instruments Corporation 13 NI USB-6008/6009 User Guide and S

Summary of the content on the page No. 14

Table 5. Digital Terminal Assignments Module Terminal Signal 17 P0.0 18 P0.1 19 P0.2 20 P0.3 21 P0.4 22 P0.5 23 P0 6 24 P0.7 25 P1.0 26 P1.1 27 P1.2 28 P1.3 29 PFI 0 30 +2.5 V 31 +5 V 32 GND NI USB-6008/6009 User Guide and Specifications 14 ni.com 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17

Summary of the content on the page No. 15

Signal Descriptions Table 6 describes the signals available on the I/O connectors. Table 6. Signal Descriptions Signal Name Reference Direction Description GND — — Ground—The reference point for the single-ended AI measurements, bias current return point for differential mode measurements, AO voltages, digital signals at the I/O connector, +5 VDC supply, and the +2.5 VDC reference. AI <0..7> Varies Input Analog Input Channels 0 to 7—For single-ended measurements, each signal is an analog

Summary of the content on the page No. 16

Analog Input You can connect analog input signals to the NI USB-6008/6009 through the I/O connector. Refer to Table 6 for more information about connecting analog input signals. Analog Input Circuitry Figure 7 illustrates the analog input circuitry of the NI USB-6008/6009. +2.5 V REF MUX PGA ADC AI FIFO 30.9 kΩ 127 kΩ AI Input Range 39.2 kΩ Selection Figure 7. Analog Input Circuitry MUX The NI USB-6008/6009 has one analog-to-digital converter (ADC). The multiplexer (MUX) routes one AI channe

Summary of the content on the page No. 17

AI FIFO The NI USB-6008/6009 can perform both single and multiple A/D conversions of a fixed or infinite number of samples. A first-in-first-out (FIFO) buffer holds data during AI acquisitions to ensure that no data is lost. Analog Input Modes You can configure the AI channels on the NI USB-6008/6009 to take single-ended or differential measurements. Refer to Table 6 for more information about I/O connections for single-ended or differential measurements. Connecting Differential Voltage Si

Summary of the content on the page No. 18

20 15 10 5 AI 1 AI 5 0 Result –5 –10 –15 –20 Figure 9. Example of a Differential 20 V Measurement Connecting a signal greater than ±10 V on either pin results in a clipped output. 20 15 10 5 AI 1 0 AI 5 Result –5 –10 –15 –20 Figure 10. Exceeding ±10 V on AI Returns Clipped Output Connecting Referenced Single-Ended Voltage Signals To connect referenced single-ended voltage signals (RSE) to the NI USB-6008/6009, connect the positive voltage signal to the desired AI terminal, and the ground s

Summary of the content on the page No. 19

AI Voltage NI USB-6008/6009 Source GND Figure 11. Connecting a Referenced Single-Ended Voltage Signal Digital Trigger When an AI task is defined, you can configure PFI 0 as a digital trigger input. When the digital trigger is enabled, the AI task waits for a rising or falling edge on PFI 0 before starting the acquisition. To use ai/Start Trigger with a digital source, specify PFI 0 as the source and select rising or falling edge. Analog Output The NI USB-6008/6009 has two independent AO cha

Summary of the content on the page No. 20

DACs Digital-to-analog converts (DACs) convert digital codes to analog voltages. Connecting Analog Output Loads To connect loads to the NI USB-6008/6009, connect the positive lead of the load to the AO terminal, and connect the ground of the load to a GND terminal. AO Load NI USB-6008/6009 GND Figure 13. Connecting a Load Minimizing Glitches on the Output Signal When you use a DAC to generate a waveform, you may observe glitches in the output signal. These glitches are normal; when a DAQ s


Alternative user manuals
# User manual Category Download
1 National Instruments NI USB-9229 User manual Computer Drive 0
2 National Instruments NI USB-9239 User manual Computer Drive 2
3 National Instruments USB-6501 OEM User manual Computer Drive 30
4 National Instruments 6211 User manual Computer Drive 28
5 National Instruments USB device 622x User manual Computer Drive 3
6 National Instruments 9211 User manual Computer Drive 3
7 National Instruments USB device 628x User manual Computer Drive 1
8 National Instruments USB device 625x User manual Computer Drive 1
9 National Instruments 6218 User manual Computer Drive 9
10 National Instruments 9211A User manual Computer Drive 2
11 National Instruments NI USB-6509 User manual Computer Drive 3
12 National Instruments 6008 User manual Computer Drive 2
13 Sony MSH-128S2 User manual Computer Drive 2
14 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
15 Sony SAITE1300-F User manual Computer Drive 0
16 Sony CRX - 160E User manual Computer Drive 0
17 Sony 2GN User manual Computer Drive 0