ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS •FOR CUSTOMER ASSISTANCE (U.S.) .................................E-2 •CONSUMER LIMITED WARRANTY (U.S.) ............................E-3 •FOR CUSTOMER ASSISTANCE (CANADA) .........................E-4 •CONSUMER LIMITED WARRANTY (CANADA) ....................E-5 •PRECAUTIONS........................
Summary of the content on the page No. 4
FOR CUSTOMER ASSISTANCE (the United States) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRI
Summary of the content on the page No. 5
CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY FOR THE U.S. USERS SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the “Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the per
Summary of the content on the page No. 6
FOR CUSTOMER ASSISTANCE (Canada) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City Province Postal Code Telephone TO PHONE: Dial 1-905-568-7140 for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For se
Summary of the content on the page No. 7
T H R O U G H T C S U E S B T O E H R LIMITED WARRANTY Consumer Electronics Products Congratulations on your purchase! Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to the first consumer purchaser for this Sharp brand product, when shipped in its original container and sold or distributed in Canada by Sharp or by an Authorized Sharp Dealer: Sharp warrants that this product is free, under normal use and maintenance, from any defects in material
Summary of the content on the page No. 8
PRECAUTIONS Points to keep in mind when using your air conditioner. WARNINGS FOR USE • Install the air conditioner in accordance with the installation instructions in the latter section of this manual. • Do not modify any part of this product. • Do not insert anything into any part of the unit. • Ensure the power supply used has an appropriate voltage rating. Only use a three-pin grounded electrical AC socket rated 125V, 60Hz, and 15 amps or more as shown on the right. Use of a power supply with
Summary of the content on the page No. 9
WARNING ABOUT GROUNDING Grounding pin 3-Pin plug • Improper use of the grounding plug can re- 3-Pin socket sult in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces Grounded electrical box the risk of an electric shock by providing a less resistant conduit for the electric current. This appliance is equipped with a cord that has a grounding wire connected to a grounding plug. The plug must be plugged into a socket that is
Summary of the content on the page No. 10
PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety. • In the event of a power failure during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less th
Summary of the content on the page No. 11
LOCATION • The air conditioner should be placed on a firm founda- tion to minimize noise and vibration. For safe and se- cure positioning, place the unit on a smooth, level floor strong enough to support the unit. • The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. MIN.12" (30cm) • The unit must be placed within reach of a properly rated grounded socket. MIN.12
Summary of the content on the page No. 12
PART NAMES FRONT VIEW 1 1 Air Outlet 2 2 Vertical louvers 3 3 Horizontal louvers 4 4 PLASMACLUSTER Lamp (blue) 5 5 Remote control signal receiver window 6 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y y Drainage nozzle and stopcock u u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power supply cord o p
Summary of the content on the page No. 13
REMOTE CONTROL 1 Transmitter 1 2 Display 3 POWER Button 4 LIGHTS Button 2 5 TEMPERATURE Button 3 6 PLASMACLUSTER Button 4 5 7 1 hr OFF Button 6 7 8 MODE Button 8 9 9 ON TIMER Button 0 q 0 FAN Button w q OFF TIMER Button e r w CANCEL Button t e LOUVERS Button r RESET Button t MEGA COOL Button REMOTE CONTROL DISPLAY y MODE SYMBOLS y : COOL : DEHUMIDIFICATION p u : FAN : VENTILATION i a u MEGA COOL SYMBOL i PLASMACLUSTER SYMBOL o s o FAN SPEED SYMBOLS : AUTO : Manual setting pTEMPERATURE AND TIMER
Summary of the content on the page No. 14
INSTALL WINDOW PANEL Installation in a double-hung sash window (See page 14 for installation in a sliding sash window. ) Hole Connect the rain guards to the insect 1 Rain guard Insect guard guard net. net Insert all three projections on each rain "A" guard into the holes in the insect guard net. Projection Side “A” will now be uppermost, as indi- cated in the diagram. Attach the guard combined above to the Projection 2 window panel Window panel Push the insect guard net firmly to ensure that its
Summary of the content on the page No. 15
Adjustment panel If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window frame width. 24"~36.8" (3) Secure the window panel to the stool with 3 screws. If the inner width of the window is between 36.8" (934mm) and 48" (1219mm) inclusive. Extension panel (1) Attach the extension panel to the adjustment panel. (2) Open the window sash and place the
Summary of the content on the page No. 16
INSTALL WINDOW PANEL Installation in a sliding sash window (See page 12 for installation in a double-hung window.) "A" Connect the rain guards to the insect 1 guard net. Insert all three projections on each rain Insect guard net guard into the holes in the insect guard net. Side “A” will now be uppermost, as Hole indicated in the diagram. Rain guard Projection Attach the guard combined above to the 2 window panel. Push the insect guard net firmly to ensure Window panel that its four projections
Summary of the content on the page No. 17
If the inner height of the window is between 24" (609mm) and 36.8" Adjustment (934mm) inclusive. panel (1) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to fit the 24"~36.8" window frame height. (3) Secure the window panel to the window frame with 3 screws. Extension panel If the inner height of the window is be- tween 36.8" (934mm) and 48" (1219mm) inclusive. (1) Attach the extension panel to the adjustment panel. 36.8"~48" (2) Open the wind
Summary of the content on the page No. 18
INSTALLATION AND REMOVAL OF EXHAUST HOSE The exhaust hose must be installed or removed in accordance with the usage mode. MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install 1 DEHUMIDIFICATION with container(minimum capacity 3 / gallons) Remove 2 Installation of the exhaust hose Attach the window exhaust adapter to 1 Window the exhaust hose. exhaust adapter Extend one end of the exhaust hose and insert it into the window exhaust adapter, and turn it (approx
Summary of the content on the page No. 19
Removal of the exhaust hose Remove the window exhaust adapter. 1 Pull out and remove the window exhaust ndow adapter by pushing down two “PUSH” haust "PUSH" apter markings, and slide and close the exhaust cover in the window panel. Remove the exhaust hose adapter from 2 the unit. Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections. Projection E-17 ENGLISH
Summary of the content on the page No. 20
PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. Always check the power plug before use. RESET Press the RESET button. 1 TEST Insert the power plug into the wall socket. 2 Press the TEST button. 3 You will hear a CLICK if the circuit breaker is functioning correctly. Press the RESET button until you hear another 4 CLICK. The circuit breaker is activated, power is supplied, and the air conditioner is now ready for use. Do not attempt to use the air conditioner i