Sharp AY-XP12FR user manual

User manual for the device Sharp AY-XP12FR

Device: Sharp AY-XP12FR
Category: Air Conditioner
Manufacturer: Sharp
Size: 0.72 MB
Added : 10/18/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sharp AY-XP12FR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sharp AY-XP12FR.

For your convenience

If looking through the Sharp AY-XP12FR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sharp AY-XP12FR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sharp AY-XP12FR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sharp AY-XP12FR User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sharp AY-XP12FR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sharp AY-XP12FR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AYXP7FR
SERVICE MANUAL
S6512AYXP7FR/T
SPLIT TYPE
ROOM AIR CONDITIONER
INDOOR UNIT OUTDOOR UNIT
MODELS
AY-XP7FR AE-X7FR
AY-XP9FR AE-X9FR
AY-XP12FR AE-X12FR
In the interests of user-safety (Required by safety regulations in some countries) the set should
be restored to its original condition and only parts identical to those specified should be used.
CONTENTS
CHAPTER 1. SPECIFICATION [5] GENERAL TROUBLESHOOTING CHAR .....T...3-6
[1] SPECIFICATION.................................... ........ 1-1 [

Summary of the content on the page No. 2

AYXP7FR AYXP7FR Service Manual CHAPTER 1. SPECIFICATION [1] SPECIFICATION 1. AY-XP7FR – AE-X7FR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP7FR AE-X7FR Cooling capacity(Min. > Max.) kW 2.1 (0.9 - 2.5) Heating capacity(Min. > Max.) kW 2.4 (0.9 - 3.4) Moisture removal(at cooling) Liters/h Electrical data Phase Single Rated frequency Hz 50 Rated voltage V 230 Rated current ✩ Cool A 2.5 (1.0 - 4.1) (Min - Max.) Heat A 2.4 (0.9 - 4.5) Rated input ✩ Cool W 530 (200 - 760) (Min - Max.) Heat W 510 (160

Summary of the content on the page No. 3

AYXP7FR 2. AY-XP9FR – AE-X9FR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP9FR AE-X9FR Cooling capacity(Min. > Max.) kW 2.64 (0.9 - 3.0) Heating capacity(Min. > Max.) kW 3.1 (0.9 - 4.8) Moisture removal(at cooling) Liters/h Electrical data Phase Single Rated frequency Hz 50 Rated voltage V 230 Rated current ✩ Cool A 3.7 (1.0 - 4.8) (Min - Max.) Heat A 3.5 (0.9 - 6.1) Rated input ✩ Cool W 780 (200 - 960) (Min - Max.) Heat W 730 (160 - 1400) Power factor ✩ Cool % 92 Heat % 91 Compressor Type Hermetic

Summary of the content on the page No. 4

AYXP7FR 3. AY-XP12FR – AE-X12FR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP12FR AE-X12FR Cooling capacity(Min. > Max.) kW 3.5 (0.9 - 3.8) Heating capacity(Min. > Max.) kW 4.0 (0.9 - 6.0) Moisture removal(at cooling) Liters/h Electrical data Phase Single Rated frequency Hz 50 Rated voltage V 230 Rated current ✩ Cool A 5.0 (1.1 - 8.2) (Min - Max.) Heat A 4.8 (1.0 - 8.0) Rated input ✩ Cool W 1090 (210 - 1300) (Min - Max.) Heat W 1030 (180 - 1900) Power factor ✩ Cool % 95 Heat % 93 Compressor Type He

Summary of the content on the page No. 5

4.5 AYXP7FR [2] EXTERNAL DIMENSION 1. Indoor unit 790 198 18.5 58 INVERTER AIR CONDITIONER 22.0 2. Outdoor unit 515 135 72 12 37.5 58 14 250 730 165 167.5 1 – 4 540 175 299 324 81 136 278

Summary of the content on the page No. 6

AYXP7FR [3] WIRING DIAGRM 1. Indooa unit 2. Outdooa unit 2.1. AE-X7FR / AE-X9FR 420V 420V 750μF 750μF 2.2. AE-X12FR 1 – 5

Summary of the content on the page No. 7

AYXP7FR [8] TROUBLESHOOTING GUIDE 1. Self-Diagnosis Function and Display Mode To call out the content of the self-diagnosis memory, hold down the emergency operation button for more than 5 seconds when the indoor unit is not operating. • The number of indications displayed by the LEDs on the outdoor unit differs from that for the 2001 cooling unit models (for detailed display of mal- function information). The display of malfunction No. differs from that of the 2001 cooling unit models. To show

Summary of the content on the page No. 8

AYXP7FR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit *2 display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 2 times 2 -0 Cycle tempera- Compressor high- (1) Check the outdoor unit air (1) Ensure unobstructed outdoor ture temperature error outlet for blockage. air flow from the out- units in door unit air outlet. complete (2) Check if the

Summary of the content on the page No. 9

AYXP7FR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit *2 display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 6 times 6 -0 Outdoor unit DC DC overcurrent error (1) IPM continuity check (1) Replace the outdoor outdoor unit control PWB units in assembly. complete (2) Check the IPM and heat (2) Correct the installa- shutdown sink for secure i

Summary of the content on the page No. 10

AYXP7FR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit *2 display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 11 11 -0 Outdoor unit DC Outdoor unit DC fan (1) Check connector CN3 of (1) Correct the installa- outdoor times fan rotation error the outdoor unit DC fan tion. units in motor for secure installa- complete tion. shutdown (2) Check the

Summary of the content on the page No. 11

AYXP7FR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit *2 display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 19 -0 Indoor unit fan Indoor unit fan error (1) Check the indoor fan (1) Replace the indoor fan outdoor motor for proper rotating motor. units in operation.(Check fan complete lock.) shutdown (2) Check the lead wire of the (2) Repla

Summary of the content on the page No. 12

AYXP7FR Malfunction indications due to erroneous wiring during air conditioner installation Inter-unit wiring error mode Symptom 1 Indoor unit relay Turns On momentarily, then turns Off. Malfunction diagnosis display "18-1" 1 1 Indoor Outdoor N N unit unit 2 2 2 Indoor unit relay Relays turns Off after about 30 minutes. Malfunction diagnosis display None 1 1 (Displays "18-0" when malfunction code is called out.) Indoor Outdoor N N unit unit 2 2 3 Indoor unit relay Relays turns Off after about 30

Summary of the content on the page No. 13

AYXP7FR [4] PERFORMANCE CURVES NOTE 1) Indoor fan speed: Hi 2) Vertical adjustment louver "45 °”, Horizontal adjustment louver "front" 3) Indoor air temp. : Cooling 27 °C, Heating 20 °C 4) Power source : 230V, 50Hz 1. AY-XP7FR 1.1. At Cooling 1.2. At Heating 600 600 500 500 400 400 300 3.0 2.6 2.5 2.0 2.4 1.5 2.2 2.0 25 30 35 40 -5 0 51 7 0 Outside air temp.(ºC) Outside air temp.(ºC) 2. AY-XP9FR 2.1. At Cooling 2.2. At Heating 800 900 800 700 700 600 600 3.2 3.5 3.0 3.0 2.8 2.5 2.6 2.0 2.4 -5 0

Summary of the content on the page No. 14

AYXP7FR 3. AY-XP12FR 3.1. At Cooling 3.2. At Heating 1200 1200 1100 1100 1000 1000 900 900 800 4.0 4.5 3.8 4.0 3.6 3.5 3.4 3.0 3.2 2.5 25 30 35 40 -5 0 5 7 10 Outside air temp.(ºC) Outside air temp.(ºC) 4 – 3 Cooling capacity(kW) Input(W) Heating capacity(kW) Input(W)


Alternative user manuals
# User manual Category Download
1 Sharp 66129902992 User manual Air Conditioner 124
2 Sharp AE-X9FR User manual Air Conditioner 69
3 Sharp AF-06ERL User manual Air Conditioner 25
4 Sharp AF-08ERL User manual Air Conditioner 26
5 Sharp AF-100DX User manual Air Conditioner 20
6 Sharp AE-X12FR User manual Air Conditioner 48
7 Sharp AF-Q120RX User manual Air Conditioner 22
8 Sharp AF-Q120PX User manual Air Conditioner 15
9 Sharp AF-Q100RX User manual Air Conditioner 6
10 Sharp AE-X7FR User manual Air Conditioner 12
11 Sharp AF-Q80RX User manual Air Conditioner 14
12 Sharp AF-Q100PX User manual Air Conditioner 2
13 Sharp AF-R100CX User manual Air Conditioner 3
14 Sharp AF-Q60RX User manual Air Conditioner 11
15 Sharp AF-R120CX User manual Air Conditioner 8
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21