Sanyo XMHS0972 user manual

User manual for the device Sanyo XMHS0972

Device: Sanyo XMHS0972
Category: Air Conditioner
Manufacturer: Sanyo
Size: 7.53 MB
Added : 6/25/2013
Number of pages: 105
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo XMHS0972. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo XMHS0972.

For your convenience

If looking through the Sanyo XMHS0972 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo XMHS0972 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo XMHS0972 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo XMHS0972 User manual - Online PDF
Advertisement
« Page 1 of 105 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo XMHS0972 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo XMHS0972. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
INDOOR UNIT : XMHS0972 & PNR-XS1872
FILE NO.
XMHS1272 & PNR-XS1872
XHS1872 & PNR-XS1872
Destination: North America
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No.
Capacity
Body (Panel) Body (Panel)
9,000BTU / h XMHS0972 (PNR-XS1872) 1 852 353 74 (1 852 352 11)
11,900BTU / h XMHS1272 (PNR-XS1872) 1 852 353 73 (1 852 352 11)
17,500BTU / h XHS1872 (PNR-XS1872) 1 852 352 07 (1 852 352 11)
Semi-Concealed Type Indoor Unit
Body
< Applicable Mu

Summary of the content on the page No. 2

SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequence

Summary of the content on the page No. 3

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When th

Summary of the content on the page No. 4

TABLE OF CONTENTS Page ............................................................................................................. 2 SAFETY PRECAUTIONS .................................................................................................................... 4 TABLE OF CONTENTS .................................................................................... 6 APPLICABLE MULTI-OUTDOOR UNITS ...................................................................................

Summary of the content on the page No. 5

Page ......................................................................................... A-4 APPENDIX D INSTRUCTION MANUAL (STK-RCS-7TWSUA) ............................................................................ A-5 APPENDIX E INSTALLATION INSTRUCTIONS (STK-RCS-7TWSUA) 5

Summary of the content on the page No. 6

APPLICABLE MULTI-OUTDOOR UNITS Multi-Outdoor Unit 3-Room 4-Room 4-Room CMH1972 CMH2472 CMH3172 Indoor Unit XMHS0972 & PNR-XS1872 YES YES YES XMHS1272 & PNR-XS1872 YES YES YES XHS1872 & PNR-XS1872 YES YES YES 6

Summary of the content on the page No. 7

1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F D.B. / 71 °F W.B. 115 °F D.B. Cooling Minimum 67 °F D.B. / 57 °F W.B. 67 °F D.B. Maximum 80 °F D.B. / 67 °F W.B. 75 °F D.B. / 65 °F W.B. Heating _ _ Minimum D.B. / W.B. 0 °F D.B. 7

Summary of the content on the page No. 8

2. SPECIFICATIONS 2-1. Unit Specifications 2-1-1. Indoor Unit XMHS0972 & PNR-XS1872 <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 9,000 12,300 kW 2.65 3.6 3 3 Air Circulation (High) ft /min (m /h) 221 (375) 247 (420) Moisture Removal (High) Pints/h 3.4 - Available Voltage Range V 187 to 253 Running Amperes A 0.1 0.12 Power Input W 16 18 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wirel

Summary of the content on the page No. 9

Indoor Unit XMHS0972 & PNR-XS1872 <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 9,000 12,300 kW 2.65 3.6 3 3 Air Circulation (High) ft /min (m /h) 221 (375) 247 (420) Moisture Removal (High) Pints/h 3.4 - Available Voltage Range V 187 to 253 Running Amperes A 0.11 0.13 Power Input W 15 17 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF T

Summary of the content on the page No. 10

Indoor Unit XMHS1272 & PNR-XS1872 <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 11,900 13,600 kW 3.5 4.0 3 3 Air Circulation (High) ft /min (m /h) 235 (400) 268 (455) Moisture Removal (High) Pints/h 4.26 - Available Voltage Range V 187 to 253 Running Amperes A 0.11 0.13 Power Input W 17 19 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF

Summary of the content on the page No. 11

Indoor Unit XMHS1272 & PNR-XS1872 <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 11,900 13,600 kW 3.5 4.0 3 3 Air Circulation (High) ft /min (m /h) 235 (400) 268 (455) Moisture Removal (High) Pints/h 4.26 - Available Voltage Range V 187 to 253 Running Amperes A 0.12 0.14 Power Input W 16 18 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF

Summary of the content on the page No. 12

Indoor Unit XHS1872 & PNR-XS1872 <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 17,500 20,400 kW 5.15 6.0 3 3 Air Circulation (High) ft /min (m /h) 341 (580) 383 (650) Moisture Removal (High) Pints/h 4.89 - Available Voltage Range V 187 to 253 Running Amperes A 0.15 0.19 Power Input W 22 27 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF

Summary of the content on the page No. 13

Indoor Unit XHS1872 & PNR-XS1872 <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 17,500 20,400 kW 5.15 6.0 3 3 Air Circulation (High) ft /min (m /h) 341 (580) 383 (650) Moisture Removal (High) Pints/h 4.89 - Available Voltage Range V 187 to 253 Running Amperes A 0.16 0.2 Power Input W 22 27 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF T

Summary of the content on the page No. 14

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit (Body) XMHS0972 Control PCB Part No. CB-XMHS0972 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-7MHVPSW4U Fan Type Turbo Q'ty ... Dia. and Length inch (mm) 1 ... D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model ... Q'ty SIC-69FV-D866-1 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 440 / 490 Rating Voltage / Nominal Output DC280V / 23W Coil Resistance Ohm - (Ambient Temp. 68 °F (2

Summary of the content on the page No. 15

Indoor Unit (Body) XMHS1272 Control PCB Part No. CB-XMHS1272 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-7MHVPSW4U Fan Type Turbo Q'ty ... Dia. and Length inch (mm) 1 ... D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model ... Q'ty SIC-69FV-D866-1 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 470 / 520 Rating Voltage / Nominal Output DC280V / 23W Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Thermal Fuse Over- Current Prot

Summary of the content on the page No. 16

Indoor Unit (Body) XHS1872 Control PCB Part No. CB-XHS1872 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-7MHVPSW4U Fan Type Turbo Q'ty ... Dia. and Length inch (mm) 1 ... D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model ... Q'ty SIC-72FV-D866-1B ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 650 / 720 Rating Voltage / Nominal Output DC340V / 20W Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over- Curren

Summary of the content on the page No. 17

2-3. Other Component Specifications Indoor Unit XMHS0972 & PNR-XS1872 XMHS1272 & PNR-XS1872 XHS1872 & PNR-XS1872 • Indoor air temp sensor • Indoor heat exchanger sensor (Model:KTEC-35-S98) (Model:PT2M-51H-S3) 10 200 9 180 8 160 7 140 6 120 5 100 4 80 3 60 2 40 1 20 0 0 50 59 68 77 86 95 104 32 50 68 86 104 122 140 158 176 194 (10) (15) (20) (25) (30) (35) (40) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) Temperature °F (°C) 17 Resistance (k ohm) Resistance (k o

Summary of the content on the page No. 18

3. DIMENSIONAL DATA Indoor Unit XMHS0972 & PNR-XS1872 XMHS1272 & PNR-XS1872 XHS1872 & PNR-XS1872 Unit : inch (mm) 18 A A 23-5/8 (600) Ceiling opening dimensions 21-1/32 (534) Suspension bolt pitch Air intake 1 Center of Discharge outlet 2 7 panel Refrigerant tubing (liquid tube) dia. 1/4" (flared) 3 Refrigerant tubing (gas tube) dia. 1/2" (flared) 8 4 4-29/32 5 Drain tube connection port VP20 (outer dia. 1") A View Power supply port 6 7 Suspension bolt hole (4 - 1/2" x 1-1/8" hole) 8 Fr

Summary of the content on the page No. 19

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit XMHS0972 & PNR-XS1872 XMHS1272 & PNR-XS1872 Indoor unit O.D. 3/8" (9.52 mm) O.D. 1/4" (6.35 mm) Cooling cycle Heating cycle Indoor Unit XHS1872 & PNR-XS1872 Indoor unit O.D. 1/2" (12.7 mm) O.D. 1/4" (6.35 mm) Cooling cycle Heating cycle 19 Strainer Strainer Heat exchanger Heat exchanger

Summary of the content on the page No. 20

5. ELECTRICAL DATA 5-1. Electric Wiring Diagrams Indoor Unit XMHS0972 & PNR-XS1872 XMHS1272 & PNR-XS1872 XHS1872 & PNR-XS1872 20 TO OUTDOOR UNIT 1 2 3 TERMINAL BASE FLAP (W) FLAP (R) IND LAMP ASSY 1 2 3 4 5 1 2 3 4 5 THERMISTOR 1 2 3 4 5 6 7 8 9 10 DRAIN PUMP 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 GND FAN MOTOR DP BRN FM RED ORG 1 2 3 4 5 6 YEL 1 2 3 4 5 6 PNK BLU VLT 1 2 3 4 5 6 1 3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 1 2 3 4 5 6 7 1 2 3 4 5 1 3 1 2 1 2 1 2 3 4 5 6 1 3 1 2 3 4 5 6 7 1


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21