UV-AIRE AIR PURIFYING SYSTEM
Model: UV-16/120
ITEMS INCLUDED IN KIT
1- UV-Aire Ballast Assembly & Power Cord
1- Mounting Base
1- Ultraviolet Lamp
6- Sheet Metal Mounting Screws
1- Instruction Sheet
1- Fiberglass Duct Board Mounting Bracket
1- UVC Light Shield
The UV-Aire unit is designed to emit powerful UVC band light rays which sterilize and reduce airborne
microorganisms as they pass through a heating or air conditioning system. It is installed in the main supply
or return duct and opera
Summary of the content on the page No. 2
SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the UV-Aire Air Purifying System out of the plenum. • Designed for a closed duct system. Do not mount near a supply or a return air opening. • All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent sealing methods. WARNING: UV light will break down plast
Summary of the content on the page No. 3
GENERAL INFORMATION The UV-Aire unit uses technology that is recommended by doctors who state that “ultraviolet radiation, properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a 1 widely applicable means of air disinfection”. Optional UVC-Light Shield: Designed to mount at virtually any angle to guard or shield certain plastics, wiring or air filters that may be affected by UVC light. SIZING AND SELECTING UNITS Optional UVC-Light Shield UV-Air
Summary of the content on the page No. 4
1 4. Cut out the large opening (1 ⁄2" hole) on the template. (See Figure 3) 1 1 5. Using a ⁄4" to ⁄2" drill bit, drill a viewport hole as indicated on the template. (See Figure 3) 6. Optional Light Shield: The light shield may be mounted at virtually any angle. However, when deciding on a suitable location, the mounting screw head can not be in the shaded area of template. (See Figure 4) 7. Press shield onto duct wall then secure with screws. (See Figure 5) 8. Attach the UV-Aire mounting base
Summary of the content on the page No. 5
9. Do not handle the lamp with bare hands. Oils on your hands tend to reduce lamp intensity. Install lamp into ballast.(See Figure 6) 10. Wipe off the lamp glass with the supplied alcohol wipe. Then insert the lamp through the center hole of the mounting base.(See Figure 7) The power cord must be 90° to the viewport hole on the mounting base. 11. With the ballast pressed against the mounting base, rotate the ballast clockwise 90º. 12. Do not wire the unit into the appliance fan circuit. Pre
Summary of the content on the page No. 6
MAINTENANCE WARNING: Always unplug unit from the electrical outlet before commencing inspection and cleaning. NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass. 1. We recommend inspecting and cleaning the lamp at least every 6 months. Frequency depends upon the environment. Such as: the type of air filter, duration of use and replacement cycle. 2. To maintain maximum output intensity, replace the UV-Aire l
Summary of the content on the page No. 7
TROUBLESHOOTING GUIDE 1. Check to make sure 120VAC power is available at the electrical outlet. 2. Do not wire the unit into the appliance fan circuit. This will cause premature ballast or lamp failure and void the warranty. For proper operation, the unit requires 120VAC at all times. 3. Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety switch is fully engaged. 4. If lamp does not light up, rotate ballast slightly clockwise or counte
Summary of the content on the page No. 8
LIMITED WARRANTY Field Controls, LLC (“Company”) warrants that its products shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of manufacture, subject to the provisions 1-8 below. Eighteen (18) months All Field Controls Products (except for those listed below as 5 years or 90 days). Five (5) years Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV). Field Controls warrants that th