Sanyo SPW-XR254EH56 user manual

User manual for the device Sanyo SPW-XR254EH56

Device: Sanyo SPW-XR254EH56
Category: Air Conditioner
Manufacturer: Sanyo
Size: 4.97 MB
Added : 5/4/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo SPW-XR254EH56. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo SPW-XR254EH56.

For your convenience

If looking through the Sanyo SPW-XR254EH56 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo SPW-XR254EH56 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo SPW-XR254EH56 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo SPW-XR254EH56 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo SPW-XR254EH56 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo SPW-XR254EH56. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND OPERATION MANUAL
– DC INVERTER Air Conditioner –
for Refrigerant R410A
 R410A Models
Indoor Units
SPW-XR254EH56
SPW-XR364EH56
SPW-XR484EH56
Outdoor Units
SPW-CR254GVH56-C, SPW-CR364GVH56-C, SPW-CR484GVH56-C
C Outdoor Units
SPW-CR254GV56-C, SPW-CR364GV56-C, SPW-CR484GV56-C
* Refrigerant R410A is used in the outdoor units.
Optional Controllers
Remote Controller RCS-SH80AG
Wireless Remote Controller RCS-TH80AG.WL
RC Wireless Remote Controller RCS-BH80AG.WL
Simplified Remote Contr

Summary of the content on the page No. 2

IMPORTANT! Please Read Before Starting When Installing… …In a Room This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an Properly insulate any tubing run inside a room to prevent important part of your job to install or service the system so it “sweating” that can cause dripping and water damage to operates safely and efficiently. walls and floors. …In Moist or Uneven Locations For safe installation and trouble-free operation,

Summary of the content on the page No. 3

2. The standards for minimum room volume are as Check of Density Limit follows. The room in which the air conditioner is to be (1) No partition (shaded portion) installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. The refrigerant (R410A), which is used in the air condi- tioner, is safe, without the toxicity or combustibility of ammonia, and is not restricted by laws imposed to pro- tect the ozone layer. However, since it contains

Summary of the content on the page No. 4

CONTENTS Page Page IMPORTANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2-9. Duct for Fresh Air Please Read Before Starting 3. ELECTRICAL WIRING . . . . . . . . . . . . . . . . . . .13 Check of Density Limit 3-1. General Precautions on Wiring 3-2. Recommended Wire Length and Wire Diame- 1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1-1. Tools Required for Installation (not supplied) ter for Power Supply System 1-2. Accessories supplied with the uni

Summary of the content on the page No. 5

2. HOW TO INSTALL THE INDOOR UNIT Hole-in-anchor 2-1. Suspending the Indoor Unit Hole-in-plug Concrete Insert This unit uses a drain pump. Use a carpenter’s level to check that the unit is level. 2-2. Preparation for Suspending (1) Fix the suspension bolts securely in the ceiling Suspension bolt (M10 or 3/8") using the method shown in the diagrams (Figs. (field supply) 2-1 and 2-2), by attaching them to the ceiling 0038_T_I Fig. 2-1 support structure, or by any other method that ensures that the

Summary of the content on the page No. 6

2-3. Placing the Unit Inside the Ceiling (1) When placing the unit inside the ceiling, deter- Full-scale installation diagram mine the pitch of the suspension bolts using the (printed on a cardboard packing) supplied full-scale installation diagram. (Fig. 2-4) The size of the opening for the indoor unit can be confirmed by attaching the full-scale installation diagram beneath the unit. (Fig. 2-4) Tubing and wiring must be laid inside the ceiling when suspending the unit. If the ceiling is alread

Summary of the content on the page No. 7

2-4. Installing the Drain Piping Transparent part for Hard PVC pipe Hose band checking drainage (not supplied) (supplied) (1) Prepare standard hard PVC pipe for the drain and use the supplied drain hose and hose band to prevent water leaks. The PVC pipe must be purchased separately. The transparent part allows you to check drain- age. (Fig. 2-6) Drain hose Packing Drain hose adapter (supplied) (supplied) (supplied) 0964_X_I Tighten the hose clamps Fig. 2-6 CAUTION so their locking nuts face upwa

Summary of the content on the page No. 8

2-5. Checking the Drainage After wiring and piping are completed, use the follow- ing procedure to check that the water will drain smoothly. For this, prepare a bucket and wiping cloth ready to catch and wipe up spilled water. Do not supply power to the unit until the tubing and wiring to the outdoor unit are completed. (1) Take off the tube cover and through the opening, slowly pour about 1,200 cc of water into the drain pan to check drainage. (2) Do Test Run to check the drainage after complet

Summary of the content on the page No. 9

n Ceiling Panel Never touch or attempt to move the air direction louver CAUTION by hand or you may damage the unit. Instead, use the remote control unit if you want to change the direction or air flow. 2-6. Before Installing the Ceiling Panel (1) Remove the air-intake grille and air filter from the ceiling panel. (Figs. 2-13 and 2-14) (a) Remove the 2 screws on the latch of the air- intake grille. (Fig. 2-13) Screw (b) Press on the 2 latches of the air-intake grille Latch with your thumb in the

Summary of the content on the page No. 10

2-7. Installing the Ceiling Panel (1) Lift the ceiling panel and position it to align the (5) Install the air filter and air-intake grille by perform- panel hook with the panel catch of the indoor unit. ing the steps in section 2-6 in reverse. NOTE NOTE The ceiling panel must be mounted in the correct Rehook the safety string before closing the air-intake direction. Note that the 2 catches of the panel differ in grille. size. Confirm that the catches are correctly matched be- 2-8. When Removing

Summary of the content on the page No. 11

ø112 2-9. Duct for Fresh Air For fresh air intake l There is a duct connection part on sideface of the indoor unit. (Fig. 2-16) l Optional air-intake plenum (including duct connection box and flange) can be attached to the indoor unit. Air-intake plenum Type CMB-GSJ80U 25 CMB-GSJ140U 36, 48 55 Detail of fresh air intake (1) Accessories 2264_X_S l Check that the following parts are in the box when unpacking. Fig. 2-16 NAME QT’Y REMARKS Cord with socket Connecting line. Not ne

Summary of the content on the page No. 12

(e) Installing the ceiling panel Duct connection l Attach the ceiling panel to the chamber. flange Duct connection box Drawing the panel downwards sets the panel in Installation screws position temporarily with the panel catch (at 2 (M4 × 12) locations). l Remove the socket cover of the air-intake plenum and pass the 8P sockets through it. (Fix the panel lead wire to chamber side clamper.) (Fig. 2-17) Panel catch l Connect the 8P socket (electrical component box side) to the 8P socket (ceiling

Summary of the content on the page No. 13

3. ELECTRICAL WIRING 3-1. General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit (7) Regulations on wire diameters differ from locality as shown on its nameplate, then carry out the to locality. For field wiring rules, please refer to wiring closely following the wiring diagram. your LOCAL ELECTRICAL CODES before begin- ning. (2) Provide a power outlet to be used exclusively for each unit, and a power supply disconnect and cir- You must ensure that installati

Summary of the content on the page No. 14

3-3. Wiring System Diagrams Indoor unit (No. 1) L Outdoor unit Power supply 1 N INV unit 220-240V 50Hz 2 A L Power supply L C 200-240V 50Hz Ground B N U1 N Remote U2 D controller Ground 1 1 R1 WHT 1 2 2 R2 BLK 2 Ground C Indoor unit (No. 2) L Power supply 1 N 220-240V 50Hz 2 Ground B U1 U2 R1 R2 Ground C Indoor Group control: unit (No. 3) L Power supply 1 N 220-240V 50Hz 2 Ground B U1 E U2 R1 R2 Ground C Indoor unit (No. n) L Power supply 1 N 220-240V 50Hz 2 Ground B U1 U2 R1

Summary of the content on the page No. 15

CAUTION (1) When linking outdoor units in a network (S-net link system), disconnect the terminal extended from the short plug (CN003, 2P Black, location: right bottom on the outdoor main control PCB) from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) Otherwise the communication of S-net link system is not performed. For a system without link (no con- nection wiring between outdoor units), do not remove the short plug. (2) Do not install the inter-

Summary of the content on the page No. 16

(5) Use shielded wires for inter-unit control wiring (c) and ground the shield on both sides, other- wise misoperation from noise may occur. (Fig. 3-4) Connect wiring as shown in Section “3-3. Shielded wire Wiring System Diagrams.” Ground Ground Loose wiring may cause the terminal to overheat or WARNING result in unit malfunction. Fig. 3-4 A fire hazard may also exist. Therefore, ensure that all wiring is tightly connected. When connecting each power wire to the terminal, fol- low the instructi

Summary of the content on the page No. 17

Deburring 4. HOW TO PROCESS TUBING Before After The narrow tubing side is connected by a flare nut, and the wide tubing side is connected by brazing. 4-1. Connecting the Refrigerant Tubing Use of the Flaring Method Many of conventional split system air conditioners employ the flaring method to connect refrigerant tubes which run between indoor and outdoor units. In this method, the copper tubes are flared at each end and connected with flare nuts. Fig. 4-1 Flaring Procedure with a Flare Tool (1

Summary of the content on the page No. 18

Caution Before Connecting Tubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or water from entering the tubes before they are used. Apply refrigerant lubricant here and here (2) Be sure to apply refrigerant lubricant to the match- ing surfaces of the flare and union before connect- Fig. 4-4 ing them together. This is effective for reducing gas leaks. (Fig. 4-4) (3) For proper connection, align the union tube and flare tube straight with each other, then screw in the flare

Summary of the content on the page No. 19

 Do not use a spanner to tighten the valve stem Packed valve Charging port caps. Doing so may damage the valves.  Depending on the installation conditions, applying excessive torque may cause the nuts to crack. Valve stem Precautions for Packed Valve Operation  If the packed valve is left for a long time with the valve stem cap removed, refrigerant will leak from the valve. Therefore, do not leave the valve stem Main valve cap removed. Valve stem cap  Use a torque wrench to securely tighten

Summary of the content on the page No. 20

4-4. Taping the Tubes (1) At this time, the refrigerant tubes (and electrical wiring if local codes permit) should be taped together with armoring tape in 1 bundle. To pre- vent the condensation from overflowing the drain pan, keep the drain hose separate from the refrigerant tubing. Clamp (2) Wrap the armoring tape from the bottom of the Drain hose Insulated tubes outdoor unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn. (3


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21