Sanyo KMS1812 user manual

User manual for the device Sanyo KMS1812

Device: Sanyo KMS1812
Category: Air Conditioner
Manufacturer: Sanyo
Size: 0.33 MB
Added : 5/4/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo KMS1812. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo KMS1812.

For your convenience

If looking through the Sanyo KMS1812 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo KMS1812 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo KMS1812 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo KMS1812 User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo KMS1812 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo KMS1812. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

92-131 S/M (Basic) 2/21/01 4:49 PM Page A
SERVICE MANUAL (Basic Information)
CM3212 / KMS0712(✕2)+KMS1812
SPLIT SYSTEM AIR CONDITIONER
Indoor Unit Outdoor Unit
CM3212
KMS0712
KMS1812
8526481017300 REFERENCE NO. WM–700699
W

Summary of the content on the page No. 2

92-131 S/M (Basic) 2/21/01 4:49 PM Page B

Summary of the content on the page No. 3

92-131 S/M (Basic) 2/21/01 4:49 PM Page ii SERVICE MANUAL CM3212 / KMS0712(×2)+KMS1812 (Basic Information) WM–700699 ii

Summary of the content on the page No. 4

92-131 S/M (Basic) 2/21/01 4:49 PM Page iii • Connect all wiring tightly. Loose wiring may cause over- IMPORTANT! heating at connection points and a possible fire hazard. Please Read Before Starting When Transporting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important Be careful when picking up and moving the indoor and out- part of your job to install or service the system so it operates door units. Get a partner

Summary of the content on the page No. 5

92-131 S/M (Basic) 2/21/01 4:49 PM Page iv Table of Contents Page 1. OPERATING RANGE............................................................................................................................... 1 2. SPECIFICATIONS .................................................................................................................................... 2 Unit Specifications ...............................................................................................................

Summary of the content on the page No. 6

92-131 S/M (Basic) 2/21/01 4:49 PM Page 1 1. OPERATING RANGE CM3212 / KMS0712(×2)+KMS1812 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95°F DB / 71°F WB 115°F DB Minimum 67°F DB / 57°F WB 67°F DB WM–700699 1

Summary of the content on the page No. 7

92-131 S/M p.2 Table 2/21/01 4:55 PM Page 2 2. SPECIFICATIONS Unit Specifications Outdoor unit CM3212 Model No. Applicable indoor unit KMS0712, KMS1812 Cooling No. of indoor units 1 unit – A 1 unit – B 2 units – A + A 2 units – A + B 3 units – A + A + B BTU/h 7,000 / 7,000 18,000 / 18,000 14,000 / 14,000 25,000 / 25,000 32,000 / 32,000 Capacity kW 2.05 / 2.05 5.27 / 5.27 4.10 / 4.10 7.33 / 7.33 9.38 / 9.38 Phase, Frequency Hz Single, 60 Single, 60 Single, 60 Single, 60 Single, 60 Voltage ratin

Summary of the content on the page No. 8

92-131 S/M (Basic) 2/21/01 4:49 PM Page 3 Applicable Indoor Unit Model No. KMS0712 Type Wall-mounted Cooling BTU/h 7,000 / 7,700 Capacity kW 2.05 / 2.05 Air circulation (High) cu. ft./min. 220 / 210 Moisture removal (High) pints/h 2.2 / 2.1 Phase, Frequency Hz Single, 60 Voltage rating V 230 / 208 Available voltage range V 187 to 253 Controls Microprocessor Control unit Wireless remote control unit Temperature control IC thermostat Timer ON/OFF 24-hours & Program Fan speeds 3 Air deflector Hor

Summary of the content on the page No. 9

92-131 S/M (Basic) 2/21/01 4:49 PM Page 4 Applicable Indoor Unit Model No. KMS1812 Type Wall-mounted Cooling BTU/h 18,000 / 17,600 Capacity kW 5.27 / 5.16 Air circulation (High) cu. ft./min. 440 / 420 Moisture removal (High) pints/h 5.3 / 5.2 Phase, Frequency Hz Single, 60 Voltage rating V 230 / 208 Available voltage range V 187 to 253 Controls Microprocessor Control unit Wireless remote control unit Temperature control IC thermostat Timer ON/OFF 24-hours & Program Fan speeds 3 Air deflector H

Summary of the content on the page No. 10

92-131 S/M (Basic) 2/21/01 4:49 PM Page 5 3. DIMENSIONAL DATA Outdoor Unit: CM3212 Air intake 21/32 Air intake Air intake 21/32 25-1/16 21/32 26-3/8 4 × 15/32 dia. hole for fixing Air dischange 1/4" narrow tubing service valve 3/8" wide tubing service valve 1/2" wide tubing service valve 3-5/32 2-3/4 5-1/4 26-7/32 26-7/32 WM–700699 5 25-1/16 5-3/8 26-3/8 5-7/16 28-1/32 32-1/16

Summary of the content on the page No. 11

92-131 S/M (Basic) 2/21/01 4:49 PM Page 6 Indoor Unit: KMS0712 Rear panel (center point of gravity) 7-11/64 17-23/32 6-23/32 31-1/2 7-3/32 Center of 1-3/8 tubing hole 5-1/2 Wireless remote Drain hose O.D. 23/32 control unit (for right O.D. 1/4" narrow tubing rear) 1-49/64 O.D. 3/8" wide tubing 2-13/64 19/32 Indoor Unit: KMS1812 14-3/16 38-31/32 7-25/32 Rear panel (Center point of gravity) Wireless remote control unit 1-61/64 2-13/64 19/32 Drain hose O.D. 1-1/4 5-19/32 Center of Narrow tube

Summary of the content on the page No. 12

92-131 S/M (Basic) 2/21/01 4:49 PM Page 7 4. COOLING CAPACITY 230V CM3622 / KMS0712×1 Rating Capacity: 7,000 BTU/H Air Flow Rate: 220 CFM Evaporator Condenser Ent. Temp. °F/(°C) Ambient Temp. °F/(°C) 75 85 95 105 115 WB DB (23.9) (29.4) (35.0) (40.6) (46.1) TC 6,930 6,620 6,300 5,940 5,460 kW 0.48 0.52 0.57 0.61 0.67 59 72 (22.2) SHC 5,290 5,130 4,980 4,810 4,590 (15.0) 76 (24.4) SHC 6,030 5,880 5,730 5,560 5,330 80 (26.7) SHC 6,810 6,620 6,300 5,940 5,460 84 (28.9) SHC 6,930 6,620 6,300 5,940

Summary of the content on the page No. 13

92-131 S/M (Basic) 2/21/01 4:49 PM Page 8 208V CM3622 / KMS0712×1 Rating Capacity: 7,000 BTU/H Air Flow Rate: 210 CFM Evaporator Condenser Ent. Temp. °F/(°C) Ambient Temp. °F/(°C) 75 85 95 105 115 WB DB (23.9) (29.4) (35.0) (40.6) (46.1) TC 6,930 6,620 6,300 5,940 5,460 kW 0.47 0.51 0.56 0.60 0.66 59 72 (22.2) SHC 5,220 5,070 4,920 4,750 4,520 (15.0) 76 (24.4) SHC 5,940 5,780 5,630 5,460 5,240 80 (26.7) SHC 6,690 6,530 6,300 5,940 5,460 84 (28.9) SHC 6,930 6,620 6,300 5,940 5,460 88 (31.1) SHC

Summary of the content on the page No. 14

92-131 S/M (Basic) 2/21/01 4:49 PM Page 9 230V CM3622 / KMS1812 Rating Capacity: 18,000 BTU/H Air Flow Rate: 440 CFM Evaporator Condenser Ent. Temp. °F/(°C) Ambient Temp. °F/(°C) 75 85 95 105 115 WB DB (23.9) (29.4) (35.0) (40.6) (46.1) TC 17,820 17,010 16,200 15,280 14,040 kW 1.30 1.41 1.54 1.67 1.83 59 72 (22.2) SHC 12,350 11,900 11,460 10,970 10,340 (15.0) 76 (24.4) SHC 13,720 13,270 12,830 12,350 11,710 80 (26.7) SHC 15,150 14,700 14,260 13,780 13,140 84 (28.9) SHC 16,520 16,070 15,630 15,

Summary of the content on the page No. 15

92-131 S/M (Basic) 2/21/01 4:49 PM Page 10 208V CM3622 / KMS1812 Rating Capacity: 17,600 BTU/H Air Flow Rate: 420 CFM Evaporator Condenser Ent. Temp. °F/(°C) Ambient Temp. °F/(°C) 75 85 95 105 115 WB DB (23.9) (29.4) (35.0) (40.6) (46.1) TC 17,420 16,630 15,840 14,940 13,730 kW 1.30 1.41 1.54 1.67 1.83 59 72 (22.2) SHC 10,040 9,520 9,030 8,470 7,750 (15.0) 76 (24.4) SHC 11,360 10,850 10,350 9,790 9,070 80 (26.7) SHC 12,740 12,230 11,730 11,170 10,450 84 (28.9) SHC 14,060 13,550 13,050 12,490 1

Summary of the content on the page No. 16

92-131 S/M (Basic) 2/21/01 4:49 PM Page 11 5. REFRIGERANT FLOW DIAGRAM OUTDOOR UNIT Narrow Narrow tube INDOOR UNIT tube O.D. UNIT A service valve 1/4" (6.35 mm) A Capillary tube Drier O.D. 1/4" (6.35 mm) B O.D. 1/4" (6.35 mm) C Check port A Check INDOOR UNIT port B UNIT B Check port C Wide tube Wide tube service O.D. Accumulator valve 3/8" (9.52 mm) A O.D. 3/8" (9.52 mm) B Accumulator O.D. 1/2" (12.7 mm) C INDOOR UNIT UNIT C Accumulator WM–700699 11 Heat exchanger Heat exchanger Heat exchang

Summary of the content on the page No. 17

92-131 S/M (Basic) 2/21/01 4:49 PM Page 12 6. ELECTRICAL DATA  Electrical Characteristics CM3212 / KMS0712×1 Indoor Unit Outdoor Unit Performance at Complete Unit 230/208V – 1ø – 60Hz Fan Motor Fan Motor Compressor A 0.15 / 0.14 0.62 / 0.56 2.53 / 2.80 3.3 / 3.5 Rating Conditions W 34 / 28 140 / 126 576 / 566 750 / 720 Locked-Rotor Amperes A 0.19 / 0.18 1.95 / 1.77 22 — Remarks: Rating conditions are: Outside air temperature 95°F DB/75°F WB Indoor unit entering air temperature 80°F DB/67°F

Summary of the content on the page No. 18

92-131 S/M (Basic) 2/21/01 4:49 PM Page 13 CM3212 / KMS0712+KMS1812 Outdoor Unit Performance at Indoor Units Complete Unit 230/208V – 1ø – 60Hz Fan Motor Compressor A 0.55 / 0.54 1.45 / 1.42 9.80 / 10.64 11.8 / 12.6 Rating Conditions W 124 / 108 330 / 290 2,246 / 2,202 2,700 / 2,600 Locked-Rotor Amperes A 0.19 + 0.45 / 0.18 + 0.40 1.95 / 1.77 22 + 54 — Remarks: Rating conditions are: Outside air temperature 95°F DB/75°F WB Indoor unit entering air temperature 80°F DB/67°F WB CM3212 / KMS7012

Summary of the content on the page No. 19

92-131 S/M (Basic) 2/21/01 4:49 PM Page 14  Electrical Wiring Diagram WARNING: To avoid electrical shock hazard, be sure to Outdoor Unit: CM3212 disconnect power before checking, servicing and/or cleaning any electrical parts. Capacitor Compressor CA motor 1 S WHT 2 R OLR A BLK CMA 3 BRN RED C Terminal Capacitor Compressor plate (3P) A CB motor S WHT 1 R OLR B BLK CMB 2 ORG RED C Capacitor 3 Compressor ORG CC motor S Terminal BLK WHT plate (3P) B R BLK YEL CMC 1 RED C PNK 2 GRY GRY Thermost

Summary of the content on the page No. 20

92-131 S/M (Basic) 2/21/01 4:49 PM Page 15 Indoor Unit: KMS0712 WARNING: To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. Terminal plate WHT 1 WHT Relay 2 BLK 3 RED G ORG 3 2 1 2 1 3 2 1 2 1 WHT 1 1 1 1 BLK 2P 3P 2P 2P WHT 2 2 2 2 BLK PRY Supply CM TH1 Thermistor BRN 1 1 1 1 BLK 2P 2P BRN 2 2 2 2 BLK SEC TH2 P S CONTROLLER Thermistor 2 2 BRN BRN 1 1 Power Connector transformer 5P FM 9P SW 1 2 3 4 5 1 2 8 9 1 2 3


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21