Sanyo RCS-SH80UA user manual

User manual for the device Sanyo RCS-SH80UA

Device: Sanyo RCS-SH80UA
Category: Air Conditioner
Manufacturer: Sanyo
Size: 4.94 MB
Added : 11/14/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo RCS-SH80UA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo RCS-SH80UA.

For your convenience

If looking through the Sanyo RCS-SH80UA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo RCS-SH80UA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo RCS-SH80UA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo RCS-SH80UA User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo RCS-SH80UA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo RCS-SH80UA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

0 SANYO Control Unit Cover 5/2/01 1:40 PM Page 1
Save These Instructions!
( )
Wired type: for all indoor units
1. RCS-SH80UG
1
( )
Wireless type: for X and T type indoor units
2. RCS-SH80UA.WL
( )
Wireless type: for K and U type indoor units
RCS-BH80UA.WL
( )
Weekly Timer
3. TM-SH80UG
2
( )
System Remote Controller
4. SHA-KC64UG
Indoor Units
3
SEMI-CONCEALED CEILING-MOUNTED WALL-MOUNTED CONCEALED DUCT
(4-WAY)
XH1242 KH1242 UH1242
XH1842 KH1842 UH1842
4
XH2442 TH2442 KH2442 UH2442
XH3642 TH364

Summary of the content on the page No. 2

0 SANYO Control Unit Cover 5/2/01 1:40 PM Page 2

Summary of the content on the page No. 3

1 RCS-SH80U 5/2/01 1:38 PM Page 1 Save These Instructions! RCS-SH80UG 1 SEMI-CONCEALED CEILING-MOUNTED WALL-MOUNTED CONCEALED DUCT (4-WAY) XH1242 KH1242 UH1242 XH1842 KH1842 UH1842 XH2442 TH2442 KH2442 UH2442 XH3642 TH3642 KH3632 UH3642 XH4242 TH4242 • Split System Air Conditioner INSTRUCTION MANUAL

Summary of the content on the page No. 4

1 RCS-SH80U 5/2/01 1:38 PM Page 2 Contents Page Product Information .......................................................................................... 2 Alert Symbols ................................................................................................... 2 Installation Location.......................................................................................... 3 Electrical Requirements...................................................................................

Summary of the content on the page No. 5

1 RCS-SH80U 5/2/01 1:38 PM Page 3 Installation Location • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a gre

Summary of the content on the page No. 6

1 RCS-SH80U 5/2/01 1:38 PM Page 4 Names of Parts INDOOR UNIT SEMI-CONCEALED WALL-MOUNTED X type (4-WAY) K type Air intake Celling panel (optional) Air outlet Air intake Air outlet CEILING-MOUNTED CONCEALED DUCT T type U type Air outlet Ceiling Air intake Air outlet Air intake (optional) (optional) REMOTE CONTROL UNITS (optional) NOTE This illustration is based on the external (Wired type: (Wireless type: appearance of a standard model. available for all available for 1 Consequently, the appea

Summary of the content on the page No. 7

1 RCS-SH80U 5/2/01 1:38 PM Page 5 Remote Cotrol Unit • With this remote controller, you can operate indoor units up to 8 units. • Once you set your operation conditions, you can operate the units only by pressing the ON/OFF operation button. • For the U type, the flap position is not shown on the display. N: SENSER J: TIMER SET button B: OPERATION lamp K: TIME A: ON/OFF operation setting button buttons G: CHECK button C: MODE button O: VENTILATION button D: Temperature setting buttons L: SET

Summary of the content on the page No. 8

1 RCS-SH80U 5/2/01 1:38 PM Page 6 Remote Control Unit (continued) F: FILTER reset button Use this button to reset the filter sign . The air conditioner has a timer for the filter and informs you when the filter needs cleaning. G: CHECK button This button is used only when servicing the air conditioner. Do not use the CHECK button for normal operation. H: UNIT button When more than one indoor unit is connected, this button is used to select a unit when adjusting the airflow direction. If no u

Summary of the content on the page No. 9

1 RCS-SH80U 5/2/01 1:38 PM Page 7 Remote Control Unit (continued) NOTE 1) When two remote control units are being used in one group control* system, a) the most recent button that is pressed on any remote control unit is effective. b) either a main-remote control unit or a sub-remote control can set the timer. *Group control means that maximum up to 8 indoor units can be concurrently controlled with a remote control unit. 2) If a power failure occurs in timer mode, the time counted up to that

Summary of the content on the page No. 10

1 RCS-SH80U 5/2/01 1:38 PM Page 8 Display (Remote Control Unit) When you first turn on the ON/OFF operation button, will blink on the display of the remote controller. During this blinking, the remote controller is verifying units connected. Use the remote controller, after stops blinking. B F C I J M G L N K A D O E P H Description A: When the unit is in the heating standby mode, the indicator appears. (Refer to the description of the Special Remarks on page 12.) 1 B: The currently selected

Summary of the content on the page No. 11

1 RCS-SH80U 5/2/01 1:38 PM Page 9 Operation STEP 1, 6 STEP 3 STEP 2 STEP 4 STEP 5 NOTE To warm up the system, the power mains must be turned on at least five (5) hours before operation. STEP 1 To start the air conditioner Press the operation button (ON/OFF button). STEP 2 Setting the mode Press the MODE button to select the mode of your choice. [ (AUTO), (HEAT), (DRY), (COOL) or (FAN)] 1 STEP 3 Setting the fan speed Press the FAN SPEED selector button to select the fan speed of your choice. [

Summary of the content on the page No. 12

1 RCS-SH80U 5/2/01 1:38 PM Page 10 Adjusting the Airflow Direction  Semi-concealed type 4-way type (X) This air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote control unit. (Refer to the description of the remote control unit.) Do not move the flap with your hands.  Ceiling mounted type (T) Vertical vane Auto flap 1 A. Vertical directions (automatic) This air conditioner is equipped with an auto flap. You

Summary of the content on the page No. 13

1 RCS-SH80U 5/2/01 1:38 PM Page 11 Adjusting the Airflow Direction (continued)  Wall mounted type (K) A. Vertical directions (automatic) Confirm that the remote control unit has been turned on. Press the FLAP Indoor unit button to start the flap moving up and down. If you want to stop the flap movement and to direct the air in the desired direction, press the FLAP button again. In the cool mode, don’t direct the flap down more than 30°, otherwise, condensation may drip on to the floor. Zone

Summary of the content on the page No. 14

1 RCS-SH80U 5/2/01 1:38 PM Page 12 Special Remarks “DRY” Operation How it works • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. • In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. • The fan speed is set to “LO.” automatically, and cannot be adjusted. • “DRY” operation is not possible if the outdoor temperature is 59 °F or less. Heating Operatio

Summary of the content on the page No. 15

1 RCS-SH80U 5/2/01 1:38 PM Page 13 Setting the Timer Use this mode to turn off the appliance automatically after the length of time set. OFF timer OFF ON Set time Use this mode to turn the appliance off automatically OFF OFF after the same set time every time. OFF cycle timer ON ON Set time Set time Use this mode to start the appliance automatically after the length of time set. ON timer OFF ON Set time NOTE When two remote control units are being used, either a main-remote control unit or a

Summary of the content on the page No. 16

1 RCS-SH80U 5/2/01 1:38 PM Page 14 How to set the OFF timer ( ) (Example) To stop the air conditioner after 3.5 hours Operation Indication 1. Press the ON/OFF button to start the air conditioner. 2. Press the TIMER SET button once to The and time $ select the mode. indications (hour) flash. 3. Press the button until 3.5 is displayed. Press the button if the set time is exceeded. 4. Press the SET button to set the The indication $ OFF timer. disappears and time indications (hour) flash. How

Summary of the content on the page No. 17

1 RCS-SH80U 5/2/01 1:38 PM Page 15 Care and Cleaning 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Air Intake and outlet side Clean the air intake and outlet side of the indoor unit with a vacuum (Indoor Unit) cleaner brush, or wipe them with a clean soft cloth. If these parts are stained, use a clean cloth

Summary of the content on the page No. 18

1 RCS-SH80U 5/2/01 1:38 PM Page 16 Care and Cleaning (continued) How to remove the filter (continued) 4. Remove the air filter attached to the air intake grille. Latch Safety chain Air intake Air filter grille Bolt screw How to remove the filter (continued) Ceiling-mounted type (T): 1. Remove the bolt screws on the finger-hold using a screw driver. (After cleaning, be sure to attach the two bolt screws.) 2. Take hold of the finger-hold on the air intake grille and slide it to the rear, and th

Summary of the content on the page No. 19

1 RCS-SH80U 5/2/01 1:38 PM Page 17 Troubleshooting If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. Trouble Possible Cause Remedy Air conditioner does not 1. Power failure 1. Restore power. run at all. 2. Leakage circuit breaker has tripped. 2. Contact service center. 3. Line voltage is too low. 3. Consult your electrician or dealer. 4. Operation button is tu

Summary of the content on the page No. 20

1 RCS-SH80U 5/2/01 1:38 PM Page 18 1


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21