Bloomfield 8572 user manual

User manual for the device Bloomfield 8572

Device: Bloomfield 8572
Category: Coffeemaker
Manufacturer: Bloomfield
Size: 1.75 MB
Added : 8/26/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bloomfield 8572. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bloomfield 8572.

For your convenience

If looking through the Bloomfield 8572 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bloomfield 8572 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bloomfield 8572 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bloomfield 8572 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bloomfield 8572 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bloomfield 8572. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

611
BLOOMFIELD INDUSTRIES
OWNERS MANUAL
2 ERIK CIRCLE, P. O. Box 280
For
Verdi, NV 89439

Customer Service (775) 345-0444 Ext.502
fax: (775) 345-0569

www.wellsbloomfield.com


MODULAR
BREWING SYSTEMS

MODELS

POUR OVER AUTOMATIC AUTOMATIC
UNITS UNITS UNITS
WITH FAUCET
8542 8541 8540
8543 8573 8572
8571

Summary of the content on the page No. 2

WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty. Seller

Summary of the content on the page No. 3

TABLE OF CONTENTS WARRANTY STATEMENT xi Thank You for purchasing this SPECIFICATIONS 1 Bloomfield Industries appliance. FEATURES & OPERATING CONTROLS 2 Proper installation, professional PRECAUTIONS & GENERAL INFORMATION 3 operation and consistent AGENCY APPROVAL INFORMATION 3 maintenance of this applianc

Summary of the content on the page No. 4

FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls 2

Summary of the content on the page No. 5

PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in pr

Summary of the content on the page No. 6

INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR To enable the installer to make COMPONENT NAMES/NUMBERS a quality installation and to Unpack the unit. Inspect all components for completeness and minimize installation time, the condition. Ensure that all packing materials have been removed following suggestions and tests from the unit. should be done before the actual unit installation

Summary of the content on the page No. 7

INSTALLATION INSTRUCTIONS (continued) NSF requires that the brewer be able to be moved for cleaning NOTE: This equipment must be installed to comply with underneath. A flex line or loops of copper tubing will satisfy this applicable federal, state and requirement. See Figure 2 below. local plumbing codes and ordinances. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a p

Summary of the content on the page No. 8

OPERATION Fig. 4 Brewer Operation Diagram IMPORTANT: A. START-UP Tank must be full of water For initial start-up, or if the brewer has not been used for an before connecting brewer extended period of time: to electrical power. Heating elements will be ♦ Be sure spray disk and brew gasket are properly installed in the damaged if allowed to brew head. operate without being fully ♦ Be sure the water supply is properly connected

Summary of the content on the page No. 9

OPERATION (continued) WATER HEATER HI-LIMIT THERMOSTAT Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating THERMOBULB element. The setpoint temperature is adjustable at the thermostat. HEATER THERMOSTAT ELEMENT The element is protected from over- temperature by a hi-limit thermostat. Fig. 5 Heat Control Diagram WATER FLOW POUR-OVER FEATURE

Summary of the content on the page No. 10

BREWING COFFEE CAUTION: B. PREPARATION Burn Hazard Place one (1) genuine Bloomfield PAPER FILTER paper filter in the brew chamber. Exposed surfaces of the Add a pre-measured amount of brewer, brew chamber and fresh coffee grounds. decanter may be HOT to BREW Gently shake the brew chamber to CHAMBER the touch, and can cause level the bed of grounds. Slide the serious burns. brew chamber into place under the brew head. Fig

Summary of the content on the page No. 11

CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer Burn Hazard PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns. Bristle Brush. CAUTION: 1. Disconnect brewer from electric

Summary of the content on the page No. 12

TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit (8786, 8788) Damaged internal component or Examine wiring & connectors, wiring thermostat and heating element Repair/replace as needed Pourover - no water or too li

Summary of the content on the page No. 13

SERVICING INSTRUCTIONS ACCESS PANELS CAUTION Electric Shock Each warmer plate has a center stud which screws into a Hazard bracket. Remove warmer plates by turning counter-clockwise. Opening access panels or Solenoid door is held by two screws and a retaining lip. removing warmer plates on this brew may expose uninsulated Front Panel (In-Line Models) and Top / Rear Panel (3-Station electrical components. Models): Disconnect brewer from a. Remove wa

Summary of the content on the page No. 14

SERVICING INSTRUCTIONS (continued) CAUTION TEMPERATURE ADJUSTMENT Electric Shock Hazard Unplug power cord or turn circuit breaker OFF. Remove top panel. These procedures involve Pull vent tube out of tank lid and insert a thermometer of known exposed electrical circuits. accuracy in vent hole. Reconnect brewer to electrical power. These procedures are to be performed by qualified technical personnel only. DIAL-TYPE THERMOSTAT THERMOMETER ADJUSTING

Summary of the content on the page No. 15

SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT IMPORTANT: Water pressure must be between 20 p.s.i and The amount of water dispensed automatically during a brew cycle 90 p.s.i. flowing pressure. is controlled by the timer. If water pressure exceeds this Place empty decanter under brew chamber. Press BREW value, or if water pressure button. Brewer should dispense one decanter of water. To varies greatly, a pressure adjust amount: regulator must be

Summary of the content on the page No. 16

SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting. A. (OLD-STYLE) Remove hex nut holding inlet fitting into back of brewer. Remove two screws holding access door in place. Remove access door. Remove front panel.

Summary of the content on the page No. 17

SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY IMPORTANT: When replacing water faucet coil, also replace Unplug power cord or turn circuit breaker OFF. seal gaskets. Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer. Reassemble in reverse order. Adjust timer as described on page 13 REPLACE HOT WATER FAUCET COIL Symptom: Brewer drips continuously from brew head, except when faucet valve is tur

Summary of the content on the page No. 18

SERVICING INSTRUCTIONS (continued) CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deliming Protective Gloves,

Summary of the content on the page No. 19

SERVICING INSTRUCTIONS (continued) 7. Set the tank back into the brewer. Reassemble the tank lid to NOTE: Normally, silicone the water tank. Make sure the gasket is properly in place, hoses do not need to be then reinstall the hold-down strap. delimed. Should deliming hoses become necessary, 8. Reinstall wiring to heating element and thermostat. Reinstall Bloomfield recommends the hi-limit thermostat (if removed). For brewers with hot replacing

Summary of the content on the page No. 20

EXPLODED VIEW & PARTS LIST CABINET & RELATED COMPONENTS 18


Alternative user manuals
# User manual Category Download
1 Bloomfield 1082XL User manual Coffeemaker 0
2 Bloomfield 1000 User manual Coffeemaker 1
3 Bloomfield 1088 User manual Coffeemaker 2
4 Bloomfield 0471 User manual Coffeemaker 2
5 Bloomfield 2072FRL User manual Coffeemaker 0
6 Bloomfield 2030 User manual Coffeemaker 0
7 Bloomfield 0443 User manual Coffeemaker 0
8 Bloomfield 1072 User manual Coffeemaker 2
9 Bloomfield 0482 User manual Coffeemaker 0
10 Bloomfield 1040 User manual Coffeemaker 0
11 Bloomfield 1082 User manual Coffeemaker 1
12 Bloomfield 2074FR User manual Coffeemaker 0
13 Bloomfield 2086 User manual Coffeemaker 0
14 Bloomfield 2080 User manual Coffeemaker 0
15 Bloomfield E.B.C. Dual Automatic Airpot Coffee Brewers 1092 User manual Coffeemaker 2
16 Philips coffee maker flavor select HD7606 User manual Coffeemaker 3
17 Sony WALKMAN D-EJ2000 User manual Coffeemaker 19
18 Philips HD 7820/65 User manual Coffeemaker 62
19 Philips coffee maker flavor select HD7612 User manual Coffeemaker 91
20 Philips HD7544 User manual Coffeemaker 8