Summary of the content on the page No. 1
605
OWNERS MANUAL
for
INTEGRITY™
5-WARMER
COFFEE BREWERS
MODEL:
8752
8752KFT
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 8752 Brewer
with optional
8900-Series Decanters
PRINTED IN UNITED STATES OF AMERICA
p/n 70988 Rev. B ECN-12887 M605 050617 cps
Summary of the content on the page No. 2
605 70988 Owners Manual Integrity 5W Decanter Brewer WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment a
Summary of the content on the page No. 3
TABLE OF CONTENTS WARRANTY STATEMENT xi Thank You for purchasing this Bloomfield Industries appliance. SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 Proper installation, professional PRECAUTIONS & GENERAL INFORMATION 3 operation and consistent AGENCY LISTING INFORMATION 3 maintenance of this appliance will ensure that it gives you the very INSTALLATION INSTRUCTIONS
Summary of the content on the page No. 4
605 70988 Owners Manual Integrity 5W Decanter Brewer FEATURES AND OPERATING CONTROLS Fig. 1 Model 8752 Features and Operating Controls 2
Summary of the content on the page No. 5
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could
Summary of the content on the page No. 6
605 70988 Owners Manual Integrity 5W Decanter Brewer INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: REFER TO EXPLODED VIEWS FOR COMPONENT NAMES/ To enable the installer to make NUMBERS a quality installation and to Unpack the unit. Inspect all components for completeness and minimize installation time, the condition. Ensure that all packing materials have been removed following suggestions and tests from the unit. should be done before the
Summary of the content on the page No. 7
INSTALLATION (continued) A water shut-off valve should be installed on the incoming water NOTE: This equipment must be line in a convenient location (Use a low restriction type valve, installed to comply with such as a 1/4-turn ball valve, to avoid loss of water flow thru the applicable federal, state and valve. local plumbing codes and ordinances. NSF requires that the brewer be able to be moved for cleaning underneath. A flex line or loops of copper tubing will
Summary of the content on the page No. 8
605 70988 Owners Manual Integrity 5W Decanter Brewer OPERATION Fig. 4 Brewer Operation Diagram IMPORTANT: START-UP Tank must be full of water For initial start-up, or if the brewer has not been used for an before pressing TANK extended period of time: HEATER SWITCH "ON". Heating elements will be ♦ Be sure spray disk and brew gasket are properly installed in the damaged if allowed to brew head. operate without being ♦
Summary of the content on the page No. 9
OPERATION (continued) Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. The setpoint temperature is adjustable at the thermostat. The element is protected from over- temperature by a hi-limit thermostat. Fig. 5 Heat Control Diagram WATER FLOW POUR-OVER FEATURE Pouring any amount of cold water into the pour-over opening and into the
Summary of the content on the page No. 10
605 70988 Owners Manual Integrity 5W Decanter Brewer BREWING COFFEE A. PREPARATION CAUTION: BURN HAZARD Place one (1) genuine Bloomfield paper filter in the brew chamber. Exposed surfaces of the Add a pre-measured amount of brewer, brew chamber and fresh coffee grounds. decanter may be HOT to Gently shake the brew chamber to the touch, and can cause level the bed of grounds. Slide the serious burns. brew chamber into place
Summary of the content on the page No. 11
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer CAUTION: BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns. Bristle Brush, Bottle Brush CAUTION: SHOCK HAZARD 1. Disconnect
Summary of the content on the page No. 12
605 70988 Owners Manual Integrity 5W Decanter Brewer TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit Damaged internal component Examine wiring & connectors, or wiring thermostat and heating element Repair/replace as
Summary of the content on the page No. 13
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD TOP PANEL: Remove top panel to access hot water tank, thermostat, heating Opening access panels or elements, brew circuit tubing and faucet tubing. removing warmer plates on this Top panel is held by two screws at the front and a retaining lip at brew may expose uninsulated the rear. electrical components. Disconnect brewer from FRONT PANELS: electrical power before Remove upper front panel to ac
Summary of the content on the page No. 14
605 70988 Owners Manual Integrity 5W Decanter Brewer SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Unplug power cord or turn circuit breaker OFF. Remove top panel. These procedures involve Pull vent tube out of tank lid and insert a thermometer of known exposed electrical circuits. accuracy in hole. Reconnect brewer to electrical power. These procedures are to be Place empty container under brew chamber. Energize brewer perf
Summary of the content on the page No. 15
SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT IMPORTANT: Water pressure must be between 20 p.s.i and The amount of water dispensed automatically during a brew cycle 90 p.s.i. flowing pressure. is controlled by the timer. If water pressure exceeds this Place empty decanter under brew chamber. Press BREW value, or if water pressure button. Brewer should dispense one decanter of water. To varies greatly, a pressure adjust amount: regulator must be
Summary of the content on the page No. 16
605 70988 Owners Manual Integrity 5W Decanter Brewer SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting. Unscrew water inlet fitting from solenoid. Remove two screws holding access door in place. Remove two screws holding solenoid to door. Disconnect wiring fr
Summary of the content on the page No. 17
SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY Unplug power cord or turn circuit breaker OFF. Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer. Reassemble in reverse order. Adjust timer as described on page 13 IMPORTANT: When replacing REPLACE HOT WATER FAUCET COIL water faucet coil, also replace Symptom: Brewer drips continuously from brew head, except seal gaskets. when faucet valve is tur
Summary of the content on the page No. 18
605 70988 Owners Manual Integrity 5W Decanter Brewer SERVICING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Delime the Water Tank CHEMICAL BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Deliming chemicals may be caustic. Wear appropriate FREQUENCY: As required (Brewer slow to heat) protective gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deli
Summary of the content on the page No. 19
SERVICING INSTRUCTIONS (continued) 7. Set the tank back into the brewer. Reassemble the tank lid to NOTE: Normally, silicone the water tank. Make sure the gasket is properly in place, hoses do not need to be then reinstall lid clamps. delimed. Should deliming hoses become necessary, 8. Reinstall wiring to heating element and thermostat. Bloomfield recommends Reassemble piping for the faucet. Verify that all internal replacing the hoses.
Summary of the content on the page No. 20
605 70988 Owners Manual Integrity 5W Decanter Brewer EXPLODED VIEW & PARTS LIST CABINET ASSEMBLY ITEM PART NUMBER DESCRIPTION 1 8700-16 PLATE, WARMER COVER 4 8543-80 CLIP, MOUNTING 23 BUSHING, HEYCO 1/78 33 8543-42 GASKET, SPRAYHEAD 34 82727 SPRAY DISK, EMBOSSED 34a 8543-85 RETAINER, SPRAY DISK (DRILL & RIVET REQUIRED TO INSTALL) 35 85089 DOOR, SOLENOID 48 8516-150 LEG SET, BLACK PLASTIC (pk 4) 81732 LEG ASSY 1” 70 8706-75 BUTTON PLUG, 2” 101 ASSEMBLY, BASIN BODY 102 8542-6