Lennox Hearth Adagio ADAGIO-EN user manual

User manual for the device Lennox Hearth Adagio ADAGIO-EN

Device: Lennox Hearth Adagio ADAGIO-EN
Category: Outdoor Fireplace
Manufacturer: Lennox Hearth
Size: 6.14 MB
Added : 11/13/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lennox Hearth Adagio ADAGIO-EN. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lennox Hearth Adagio ADAGIO-EN.

For your convenience

If looking through the Lennox Hearth Adagio ADAGIO-EN user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lennox Hearth Adagio ADAGIO-EN on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lennox Hearth Adagio ADAGIO-EN to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lennox Hearth Adagio ADAGIO-EN User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lennox Hearth Adagio ADAGIO-EN but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lennox Hearth Adagio ADAGIO-EN. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
TM
ADAGIO™ Direct-Vent
Gas Fireplaces
P/N 850044M Rev. F 01/2011
MODELS
This manual is one of a set of two supporting this product.
MILLIVOLT: ELECTRONIC:
Refer to P/N 875037M for Care and Operation Instructions.
ADAGIO-MN ADAGIO-EN
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850044CF.
ADAGIO-MP
Portland
US
OTL Report No. 116-F-48-5
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for f

Summary of the content on the page No. 2

PACKAGING GENERAL INFORMATION TABLE OF CONTENTS Packaging .........................................Page 2 The assembled vented gas fireplace heater is packaged with: Introduction ......................................Page 2 WARNING General Information ..........................Page 2 Young children should be care- 1 - One log set located in firebox. Requirements for Commonwealth 2 - One envelope containing the literature fully supervised when they are of Massachusetts ...............

Summary of the content on the page No. 3

Note: Installation and repair should be done The appliance, when installed, must be electri- WARNING by a qualified service person. The appliance cally grounded in accordance with local codes should be inspected before use and at least or, in the absence of local codes, with the Improper installation, adjust- annually by a professional service person. National Electrical Code, ANSI/NFPA 70-latest More frequent cleaning may be required ment, alteration, service or edition, or the Ca

Summary of the content on the page No. 4

I O O L I P T O i t T P T H T P T H L I P F L F O Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude HI/LO Variable (All Models) Inlet Pressure Manifold Flame Height Tap Tables 2 and 3 show the appliances' inlet and Pressure Tap Adjustment manifold gas pressure requirements: These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard HI Inlet Gas Supply Pressure burner orific

Summary of the content on the page No. 5

COLD CLIMATE INSULATION TOP VENT INSTALLATIONS For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other open- ings should be caulked or stuffed with unfaced ROOM DIVIDER APPLICATION VER TICAL VENT fiberglass insulation. HORIZONT AL

Summary of the content on the page No. 6

VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances Termination Heights For Vents These instructions should be used as a TERMINATION HEIGHTS FOR VENTS ABOVE Above Flat Or Sloped Roofs FLAT OR SLOPED ROOFS guideline and do not supersede local codes Ref. NFPA 54 / ANSI Z223.1 Horizontal Overhang in any way. Install vent according to local Roof Pitch * Feet * Meters 2 FT codes, these instructions, the current National Vertical MIN. 2 FT MIN. Wall Flat to 6/12 1.0 0.3 Fuel Ga

Summary of the content on the page No. 7

V EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS NOTE: Local Codes Or Regulations May Require Different Clearances. * See Item D in the Text Below. N P N NOTE: Location Of The Vent Termination Exterior Wall Inside Must Not Interfere With Access To The Corner Detail O Electrical Service. *18” V V G Q Horizontal Termination V 6” Ventilated Soffit A Inside Corner = 9” in U.S. � A = 12” in Canada Detail D H 3 ft. B B D E C X � A � A V V L Fixed Operable V Closed Window 3 ft. Window V

Summary of the content on the page No. 8

MINIMUM CLEARANCES TO Do not insulate the COMBUSTIBLES space between the MODELS appliance and the Adagio-MN area above it. Appliance And Vent Clearances Adagio-MP Adagio-EN Header The appliance is approved with zero clearance to com- 4” � Combustible Shelf Height bustible materials on all sides (as detailed in Table 5), (102mm) Inches (millimeters) with the following exception: When the unit is installed Drywall with one side flush with a wall, the wall on the other Top Vent - with One 90

Summary of the content on the page No. 9

TYPICAL INSTALLATION SEQUENCE Step 1. FRAMING WARNING The typical sequence of installation is outlined Frame these appliances as illustrated in Figures Failure to position the parts in below. However, each installation is unique 12 and 14 on Pages 10 and 12 (Figure 14 accordance with these diagrams and may result in variations to the steps applies to corner framing installations only). or failure to use only parts specifi- described. All framing details must allow for a minimum c

Summary of the content on the page No. 10

FIREPLACE AND FRAMING SPECIFICATIONS Framing Dimensions - All Models Framing With Platform Inches (millimeters) A B C D 10¹⁄₂ (267) VENT FRAMING - in. 22-1/8 40-1/4 15-3/4 44-1/8 TOP VENT WITH ONE 90° ELBOW mm 562 1022 400 1121 Framing should be constructed of 2x4 or larger lumber * D shown here is not dimensioned to the vertical center of the horizontal framing. This is to allow for the required 4" clearance above the vent and the 1" required clearance below the vent. This does not include

Summary of the content on the page No. 11

Facade (Required) * (arched style shown) FACADE SPECIFICATIONS Arch Facades** 1/2” (13mm) - Black and Brushed Nickel Finishes 1-1/2” (38mm) Cat. Model Description No. H5773 ADAGIO-AG Arch Black H5774 ADAGIO-PF Arch Br. Nickel ** A filigree inset kit is also required (sold separately). See Care and Operation Manual for ordering 20-1/4” 38-1/2” information. (514) (978) 1/2” (13) 14-13/16” (376) 26-3/4” (680) Gated Facades Cat. No. Model Description Copper and Iron Gates H5775 ADAGIO-IG Iron

Summary of the content on the page No. 12

Top Vent With Horizontal Termination In A Corner Corner Framing Dimensions - All Models A B C D E in. 22-1/8 41-5/8 29-1/2 10 20-7/8 D mm 562 1057 749 254 530 7 (178) uWhen installing in a corner configuration, one of the rear stand-offs will need to be removed. C � E A Figure 14 - Corner Framing with Square Termination (SV4.5HT-2) B Back wall of chase/enclosure Inches (including any finishing materials) (millimeters) Never use galvanized or plastic pipe. Refer Step 2. ROUTING GAS LINE Notes:

Summary of the content on the page No. 13

Step 3. INSTALL THE VENT SYSTEM wall (such as a chase). There is no requirement Use only approved venting components. for inspection openings in the enclosing wall See Approved Vent Components on General Information at any of the joints in the vent pipe. Page 2. These instructions should be used as a Select Venting System - Horizontal or Verti- These fireplaces must be vented directly guideline and do not supersede local codes cal to the outside. in any way. Install vent according to lo

Summary of the content on the page No. 14

VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART See Figures 16, and 24 through 26 on Nominal 6 12 24 36 48 Nominal Section 6 12 24 36 48 T VENT SECTION LENGTH CHART T Length (inches) Section Length O Pages 14 and 17 and their associated Vertical O T Nominal Section 62142638 4 T (inches) VENT SECTION LENGTH CHART T O Length (inches) Vent Tables which illustrate the various vertical Net Section 4 ½ 10 ½ 22 ½ 34 ½ 46 ½ A T Nominal A T Net Section Length

Summary of the content on the page No. 15

B. Attach vent components to appliance Push the vent component against the previous Vertical (Offset) Installation - Secure Vent SV4.5 direct-vent system compo- section until it fully engages, then twist the Analyze the vent routing and determine the nents are unitized concentric pipe components component clockwise running the dimples down quantities of vent sections and number of el- featuring positive twist lock connections (see and along the incline channels until they seat at bows requir

Summary of the content on the page No. 16

One method of support is by utilizing field pro- K. Install the vertical termination - The final step involves installation of the SV4.5CGV-1 vided support straps (conventional plumber's Vertical Termination. Extend the vent sections tape). Secure the plumber's tape to the framing to the height as shown in the "Vertical vent ter- members with nails or screws. Loop the tape mination section" on Page 6. The SV4.5CGV-1 around the vent, securing the ends of the tape C Vertical Termination (

Summary of the content on the page No. 17

VERTICAL VENT FIGURES/TABLES Table A Notes: H Maximum V Minimum • Secure V ent™ (rigid vent pipe) is shown H in the Figures; Secure Flex™ (flexible vent feet (meter) feet (meter) pipe) may also be used. 5 (1.524) Elbow Only • It is ver y important that the horizontal/in- clined run be maintained in a straight (no 5 (1.524) 1 (0.305) u Ceiling Firestop / dips) and recommended to be in a slightly Spacer (SV4.5VF) 10 (3.048) 2 (0.610) elevated plane, in a directio

Summary of the content on the page No. 18

HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM Support the vertical portion of the venting system every 8 feet (2.4m) above the fireplace vent outlet. Support Brackets Building See Figures 27, and Figures 30 to 33 on Pages Support Horizontal / Inclined Run SV4.5 HT-2 18, 20 and 21 and their associated Horizontal Framing Termination Vent Table which illustrate the various horizontal SV4.5E90 Shown venting configurations that are possible for use Elbow with these appliances. Secure Vent™ pipe

Summary of the content on the page No. 19

J. Assemble vent run to exterior wall - If not To help minimize water infiltration it is previously measured, locate the center of the recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior vent at the exterior wall. Prepare an opening as side of the wall. described in Step B. Assemble the vent system SV4.5 HT-2 to point where the terminus of the last section is Termination 7" (178) located relative to the exterior surface to which 12¹⁄₈" 10¹⁄₂" (308 mm) (267mm) the t

Summary of the content on the page No. 20

See Table 8 as an aid in venting component selection for a particular range of exterior wall thicknesses. Table C H Maximum V Minimum Venting Components Required for Various Exterior Wall Thick- feet (meter) feet (meter) nesses, when using Square Termination Kit (SV4.5HT-2) 3 (0.914) Elbow Only Vent Components Required Exterior Wall Thickness - inches (mm) Termination Kit Only 6 to 9-1/4 (152 to 235) Square termination (SV4.5HT-2) shown. Termination Kit and 6 In. Vent H 10-3/4 to 14 (273


Alternative user manuals
# User manual Category Download
1 Lennox Hearth Adagio ADAGIO-EN User manual Indoor Fireplace 0
2 Lennox Hearth Adagio ADAGIO-MN User manual Outdoor Fireplace 2
3 Lennox Hearth DPSS42 User manual Outdoor Fireplace 0
4 Lennox Hearth DPSS36 User manual Outdoor Fireplace 0
5 Lennox Hearth EBVCLNE User manual Outdoor Fireplace 0
6 Lennox Hearth EBVCLPM User manual Outdoor Fireplace 0
7 Lennox Hearth EBVPFNE User manual Outdoor Fireplace 0
8 Lennox Hearth Adagio ADAGIO-MP User manual Outdoor Fireplace 0
9 Lennox Hearth EBVCLNM User manual Outdoor Fireplace 0
10 Lennox Hearth EBVCRNM User manual Outdoor Fireplace 0
11 Lennox Hearth EBVCRNE User manual Outdoor Fireplace 0
12 Lennox Hearth EBVPFPM User manual Outdoor Fireplace 0
13 Lennox Hearth EBVSTNE User manual Outdoor Fireplace 1
14 Lennox Hearth EBVCRPM User manual Outdoor Fireplace 0
15 Lennox Hearth EBVPFNM User manual Outdoor Fireplace 0
16 Blue Rhino FIREPLACE WAF513C User manual Outdoor Fireplace 0
17 Blue Rhino 255635 User manual Outdoor Fireplace 1
18 Blue Rhino GAD860SP User manual Outdoor Fireplace 3
19 Blue Rhino 252207 User manual Outdoor Fireplace 1
20 Blue Rhino 251828 User manual Outdoor Fireplace 1