Sanyo CL1271 user manual

User manual for the device Sanyo CL1271

Device: Sanyo CL1271
Category: Air Conditioner
Manufacturer: Sanyo
Size: 5.48 MB
Added : 5/29/2014
Number of pages: 108
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo CL1271. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo CL1271.

For your convenience

If looking through the Sanyo CL1271 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo CL1271 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo CL1271 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo CL1271 User manual - Online PDF
Advertisement
« Page 1 of 108 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo CL1271 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo CL1271. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
KS0971 + C0971
FILE NO.
+ CL0971
KS1271 + C1271
+ CL1271
Destination: North America
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No. Outdoor Model No. Product Code No.
KS0971 1 852 099 81 C0971 1 852 330 23
KS1271 1 852 099 82 C1271 1 852 330 24
CL0971 1 852 330 25
CL1271 1 852 330 26
Indoor Unit Outdoor Unit
KS0971 C0971
KS1271 C1271
CL0971
CL1271
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention w

Summary of the content on the page No. 2

When Transporting Important! Be careful when picking up and moving the indoor and Please Read Before Starting outdoor units. Get a partner to help, and bend your knees This air conditioning system meets strict safety and operating when lifting to reduce strain on your back. Sharp edges or thin standards. As the installer or service person, it is an aluminum fins on the air conditioner can cut your fingers. important part of your job to install or service the system so it When Installing

Summary of the content on the page No. 3

Table of Contents Page 1. OPERATING RANGE ................................................................................................................... 5 2. SPECIFICATIONS 2-1. Unit Specifications ............................................................................................................. 6 2-2. Major Component Specifications ....................................................................................... 10 2-3. Other Component Specifications ...............

Summary of the content on the page No. 4

Page 10. CHECKING ELECTRICAL COMPONENTS 10-1. Measurement of Insulation Resistance ............................................................................... 48 10-2. Checking Continuity of Fuse on PCB Ass'y ......................................................................... 49 11. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 11-1. Characteristics of New Refrigerant R410A ......................................................................... 50 11-2. Checklist be

Summary of the content on the page No. 5

1. OPERATING RANGE Models : KS0971 + C0971 KS1271 + C1271 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F D.B. / 71 °F W.B. 115 °F D.B. Cooling Minimum 67 °F D.B. / 57 °F W.B. 67 °F D.B. Models : KS0971 + CL0971 KS1271 + CL1271 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F D.B. / 71 °F W.B. 115 °F D.B. Cooling Minimum 67 °F D.B. / 57 °F W.B. 0 °F D.B. 5

Summary of the content on the page No. 6

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit KS0971 Outdoor Unit C0971 Voltage Rating 115V Single-Phase 60Hz Cooling Total Capacity BTU/h 9,000 ( 3,000 to 9,000 ) kW 2.65 ( 0.9 to 2.65 ) Sensible Capacity 7,650 BTU/h Latent Capacity BTU/h 1,350 3 3 Air Circulation (High) ft /min (m /h) 282 (480) Moisture Removal (High) Pints/h 3.4 Available Voltage Range V 104 to 126 Running Amperes A 7.6 ( 2.5 to 7.6 ) Power Input W 750 ( 250 to 750 ) Power Factor % 86 EER BTU/h/W 12 SEER BTU/Wh 16

Summary of the content on the page No. 7

Indoor Unit KS1271 Outdoor Unit C1271 Voltage Rating 115V Single-Phase 60Hz Cooling Total Capacity BTU/h 11,900 ( 3,000 to 11,900 ) kW 3.5 ( 0.9 to 3.5 ) Sensible Capacity 9,100 BTU/h Latent Capacity BTU/h 2,800 3 3 Air Circulation (High) ft /min (m /h) 294 (500) Moisture Removal (High) Pints/h 4.26 Available Voltage Range V 104 to 126 Running Amperes A 10.9 ( 2.5 to 10.9 ) Power Input W 1,090 ( 250 to 1,090 ) Power Factor % 87 EER BTU/h/W 10.9 SEER BTU/Wh 17 Compressor Locked Rotor Amperes A20

Summary of the content on the page No. 8

Indoor Unit KS0971 Outdoor Unit CL0971 Voltage Rating 115V Single-Phase 60Hz Cooling Total Capacity BTU/h 9,000 ( 3,000 to 9,000 ) kW 2.65 ( 0.9 to 2.65 ) Sensible Capacity 7,650 BTU/h Latent Capacity BTU/h 1,350 3 3 Air Circulation (High) ft /min (m /h) 282 (480) Moisture Removal (High) Pints/h 3.4 Available Voltage Range V 104 to 126 Running Amperes A 7.6 ( 2.5 to 7.6 ) Power Input W 750 ( 250 to 750 ) Power Factor % 86 EER BTU/h/W 12 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A20 Fuse or

Summary of the content on the page No. 9

Indoor Unit KS1271 Outdoor Unit CL1271 Voltage Rating 115V Single-Phase 60Hz Cooling Total Capacity BTU/h 11,900 ( 3,000 to 11,900 ) kW 3.5 ( 0.9 to 3.5 ) Sensible Capacity 9,100 BTU/h Latent Capacity BTU/h 2,800 3 3 Air Circulation (High) ft /min (m /h) 294 (500) Moisture Removal (High) Pints/h 4.26 Available Voltage Range V 104 to 126 Running Amperes A 10.9 ( 2.5 to 10.9 ) Power Input W 1,090 ( 250 to 1,090 ) Power Factor % 87 EER BTU/h/W 10.9 SEER BTU/Wh 17 Compressor Locked Rotor Amperes A2

Summary of the content on the page No. 10

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit KS0971 Control PCB Part No. CB-KS0971 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-4VPIS4U Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-11/16 / L24-31/32 (D94/L634) Fan Motor Type AC Motor Model ... Q'ty IBH-884-076 ... 1 No. of Poles 4 Rough Measure RPM (Cool) 1,200 Nominal Output W 16 Coil Resistance Ohm BRN-WHT : 57.9 (Ambient Temp. 68 °F (20 °C)) RED-WHT : 55.2 Safety Dev

Summary of the content on the page No. 11

Indoor Unit KS1271 Control PCB Part No. CB-KS1271 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-4VPIS4U Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-11/16 / L24-31/32 (D94/L634) Fan Motor Type AC Motor Model ... Q'ty IBH-884-076 ... 1 No. of Poles 4 Rough Measure RPM (Cool) 1,250 Nominal Output W 16 Coil Resistance Ohm BRN-WHT : 57.9 (Ambient Temp. 68 °F (20 °C)) RED-WHT : 55.2 Safety Device Type Thermal Fuse Operating Temp. Open °F (°C) 266 (1

Summary of the content on the page No. 12

2-2-2. Outdoor Unit Outdoor Unit C0971 Control PCB Part No. CB-C0971 Controls Microprocessor Control Circuit Fuse 125V 25A Compressor Type DC Rotary (Hermetic) Compressor Model / Nominal Output G4C090LU1ER / 900W Compressor Oil ... Amount Pints (cc) FV50S ... 0.68 (320) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm U - V : 0.81 V - W : 0.81 W - U : 0.81 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambi

Summary of the content on the page No. 13

Outdoor Unit C1271 Control PCB Part No. CB-C1271 Controls Microprocessor Control Circuit Fuse 125V 25A Compressor Type DC Rotary (Hermetic) Compressor Model / Nominal Output G4C090LU1ER / 900W Compressor Oil ... Amount Pints (cc) FV50S ... 0.68 (320) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm U - V : 0.81 V - W : 0.81 W - U : 0.81 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambient Temp. Yes Overl

Summary of the content on the page No. 14

Outdoor Unit CL0971 Control PCB Part No. CB-CL0971 Controls Microprocessor Control Circuit Fuse 125V 25A Compressor Type DC Rotary (Hermetic) Compressor Model / Nominal Output G4C090LU1ER / 900W Compressor Oil ... Amount Pints (cc) FV50S ... 0.68 (320) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm U - V : 0.81 V - W : 0.81 W - U : 0.81 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambient Temp. Yes Ove

Summary of the content on the page No. 15

Outdoor Unit CL1271 Control PCB Part No. CB-CL1271 Controls Microprocessor Control Circuit Fuse 125V 25A Compressor Type DC Rotary (Hermetic) Compressor Model / Nominal Output G4C090LU1ER / 900W Compressor Oil ... Amount Pints (cc) FV50S ... 0.68 (320) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm U - V : 0.81 V - W : 0.81 W - U : 0.81 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambient Temp. Yes Ove

Summary of the content on the page No. 16

2-3. Other Component Specifications Indoor Unit KS0971 KS1271 Outdoor Unit C0971 C1271 CL0971 CL1271 Indoor heat exchanger sensor (Model:PTM-D51H-S3 TH1) Indoor air temp sensor Compressor temp sensor (Model:PTM-D51H-S3 TH2) (Model:DTN-TKS274Y TH2) 10 200 9 180 8 160 7 140 6 120 5 100 4 80 3 60 2 40 1 20 0 0 50 59 68 77 86 95 104 32 50 68 86 104 122 140 158 176 194 (10) (15) (20) (25) (30) (35) (40) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) Temper

Summary of the content on the page No. 17

3. DIMENSIONAL DATA Indoor Unit KS0971 KS1271 Unit: inch(mm) 17

Summary of the content on the page No. 18

Outdoor Unit C0971 C1271 CL0971 CL1271 21-3/16 3-19/32 15/32 10-13/16 Wide tube service valve dia.3/8" (9.52) 28-11/32 (720) 2-1/8 Narrow tube service valve dia.1/4" (6.35) 6-3/32 Unit: inch(mm) 18 ID:23/32 2-ID:15/16 3-19/32 5/8 21-9/16 (548) 10-7/16(265) 11-13/32 12-7/16 4-9/32 2-5/32

Summary of the content on the page No. 19

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit KS0971 Outdoor Unit C0971 C1271 KS1271 CL0971 CL1271 Indoor unit Outdoor unit Wide tube service Wide tube valve Accumulator Muffler O.D. High pressure 3/8" switch (9.52 mm) H.P. Electric Narrow expansion tube valve service Narrow tube M valve Muffler O.D. *1 1/4" Cooling cycle (6.35 mm) *1: 0nly for C1271/CL1271 Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the

Summary of the content on the page No. 20

5. PERFORMANCE DATA 5-1. Temperature Charts Indoor Unit KS0971 Outdoor Unit C0971 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 115V) (1) Low pressure performance chart 173 (1.2) Lo fan Hi Fan 159 (1.1) 145 (1.0) 131 (0.9) 117 (0.8) 68 77 86 95 104 (20) (25) (30) (35) (40) Outdoor inlet air D.B. temp.°F(°C) (2) Operating current performance chart 9 Lo fan Hi Fan 8 7 6 5 4 68 77 86 95 104 (20) (25) (30) (35) (40) Outdoor inlet air D.B. temp.°F(°C) (3) Indoor dischar


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21