Desa VN1000BTA user manual

User manual for the device Desa VN1000BTA

Device: Desa VN1000BTA
Category: Gas Heater
Manufacturer: Desa
Size: 0.28 MB
Added : 6/10/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VN1000BTA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VN1000BTA.

For your convenience

If looking through the Desa VN1000BTA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VN1000BTA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VN1000BTA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VN1000BTA User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VN1000BTA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VN1000BTA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
BLUE FLAME
VENT-FREE NATURAL GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
VN1000BTA
10,000 Btu/Hr
Thermostatically-
Controlled Models
WARNING: Improper installa-
WARNING: If the information in this manual is not
tion, adjustment, alteration,
followed exactly, a fire or explosion may result caus-
service, or maintenance can
ing property damage, personal injury, or loss of life.
cause injury or property dam-
age. Refer to this manual for
— Do not store or use gasoline or other
correct in

Summary of the content on the page No. 2

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER 3. Heater shall not be installed in a bath- SAFETY Due to high temperatures, the room. appliance should be located out INFORMATION 4. This heater needs fresh, outside air ven- of traffic and away from furniture tilation to run properly. This heater has and draperies. an Oxygen Depletion Sensing (ODS) WARNINGS safety shutoff system. The ODS shuts Do not place clothing or other down the heater if not enough fresh air IMPORTANT: Read this owner’s flammabl

Summary of the content on the page No. 3

OWNER’S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES Ignitor Button SAFETY PILOT Control Knob This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system Grill Guard requires no matches, batteries, or other sources to light heater. Glass Panel Heater Front Cabinet Panel

Summary of the content on the page No. 4

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code ANS Z223.1 COMBUSTION AND defines a confined space as a space whose The following are excerpts from National VENTILATION volume is less than 50 cubic feet per 1,000 Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- Btu per hour (4.8 m3 per kw) of the aggre- tion 5.3, Air for Combustion and Ventilation. gate input rating of all appliances installed WARNING: This heater

Summary of the content on the page No. 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = ______________ cu. ft.

Summary of the content on the page No. 6

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER AIR FOR COMBUSTION AND 12" VENTILATION Continued VENTILATION AIR Ventilation Grills Ventilation Air From Inside Into Adjoining Room, Ventilation Option 2 Building Grills Or into Adjoining Remove This fresh air would come from an adjoining Room, Door into unconfined space. When ventilating to an Option 1 Adjoining adjoining unconfined space, you must pro- Room, vide two permanent openings: one within Option 3 12" of the ceiling and one within 12" o

Summary of the content on the page No. 7

OWNER’S MANUAL CEILING LOCATING HEATER INSTALLATION This heater is designed to be mounted on a NOTICE: This heater is intended wall. 36" for use as supplemental heat. Use Minimum this heater along with your pri- 6" WARNING: Maintain the mini- mary heating system. Do not in- Minimum mum clearances shown in Figure From stall this heater as your primary 4. If you can, provide greater clear- Sides Of heat source. If you have a central Heater ances from floor, ceiling, and join- heating system, you

Summary of the content on the page No. 8

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER Thin or Installing Bottom Mounting INSTALLATION Thick Wall Screw Continued (thick wall 1. Locate bottom mounting hole. This shown) Installing Two Mounting Screws 1/16" hole is near bottom on back panel of Space heater (see Figure 11). Note: Wall anchors and mounting screws are in hardware package. The hardware pack- 2. Mark screw location on wall. Solid age is provided with heater. 3. Remove heater from wall. Wall Attaching To Wall Stud Method 4. If ins

Summary of the content on the page No. 9

OWNER’S MANUAL Installation must include an equipment shutoff INSTALLATION CAUTION: Use pipe joint seal- valve, ground joint union, and plugged Continued ant that is resistant to liquid pe- 1/8" NPT tap. Locate NPT tap within reach troleum (LP) gas. for test gauge hook up. NPT tap must be CONNECTING TO GAS upstream from heater (see Figure 12). Install sediment trap (trap) in supply line as SUPPLY IMPORTANT: Install an equipment shutoff shown in Figure 12. Locate sediment trap valve in an acces

Summary of the content on the page No. 10

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER Pressure Testing Heater Gas INSTALLATION OPERATING Connections Continued HEATER 1. Open equipment shutoff valve (see Fig- CHECKING GAS ure 13). FOR YOUR SAFETY CONNECTIONS 2. Open main gas valve located on or near READ BEFORE gas meter. LIGHTING WARNING: Test all gas pip- 3. Make sure control knob of heater is in ing and connections for leaks the OFF position. WARNING: If you do not fol- after installing or servicing. Cor- 4. Check all joints from equ

Summary of the content on the page No. 11

OFF HI OWNER’S MANUAL Note: If pilot goes out, repeat steps THERMOSTAT OPERATING 3 through 7. This heater has a safety CONTROL HEATER interlock system. Wait one (1) minute OPERATION before lighting pilot again. Continued The thermostatic control used on these 8. Turn control knob counterclockwise LIGHTING models differs from standard thermo- to desired heating level. The C-clockwise INSTRUCTIONS stats. Standard thermostats simply turn main burner should light. Set control on and off the burner.

Summary of the content on the page No. 12

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER CLEANING BURNER INSPECTING NOTICE: Do not mistake orange PILOT AIR INLET HOLE flames with yellow tipping. Dust BURNER or other fine particles enter the We recommend that you clean the unit every heater and burn causing brief Check pilot flame pattern and burner flame 2,500 hours of operation or every three months. patches of orange flame. pattern often. We also recommend that you keep the burner tube and pilot assembly clean and free of dust PILOT FLAME

Summary of the content on the page No. 13

OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater CAUTION: Never use a wire, and let cool before servicing. Only Note: For additional help, visit DESA needle, or similar object to clean a qualified service person should International’s technical service web site ODS/pilot. This can damage ODS/ service and repair heater. at www.desatech.com. pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed,

Summary of the content on the page No. 14

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice is clogged 1. Clean burner orifice (see Cleaning and Maintenance, page 12) or replace burner orifice 2. Burner orifice diameter is too small 2. Replace burner orifice 3. Inlet gas pressure is too low 3. Contact local natural gas company Delayed ignition of burner 1. Manifold pressure is too low 1. Contact local natural gas comp

Summary of the content on the page No. 15

OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette

Summary of the content on the page No. 16

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER ILLUSTRATED 22 21 PARTS BREAKDOWN 20 VN1000BTA 10 14 16 13 19 23 12 24 10 18 4 11 14 15 7 9 6 3 5 17 8 2 12-1 1 12-2 ODS/PILOT 104265 16

Summary of the content on the page No. 17

OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions PARTS LIST listed under Replacement Parts on page 18 of this manual. VN1000BTA KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembly 1 3 099318-04 Grill Guard 1 4 101108-01 Grill Guard Clip 2 5 102017-02 Bottom Glass Retainer 1 6 098260-11 Glass Panel 1 7 098532-06AA Top Glass Retainer 1 8 M11084-38 Screw, #8 x 3/8" 8 9 098352-03BR

Summary of the content on the page No. 18

® BLUE FLAME 10,000 BTU NATURAL GAS HEATER SPECIFICATIONS REPLACEMENT VN1000BTA PARTS Btu(Variable) 5,000/10,000 Note: Use only original replacement parts. Type Gas Natural Only This will protect your warranty coverage for Ignition Piezo parts replaced under warranty. Pressure Regulator Setting 3" W.C. PARTS UNDER WARRANTY Inlet Gas Pressure (inches of water) 10.5" Max. / 4" Min. Contact authorized dealer from whom you Heater Dimensions purchased this product. If they cannot sup- (Includes knobs

Summary of the content on the page No. 19

OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________

Summary of the content on the page No. 20

WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) yea


Alternative user manuals
# User manual Category Download
1 Desa 125-R User manual Gas Heater 0
2 Desa BG30P User manual Gas Heater 0
3 Desa 30-80 User manual Gas Heater 0
4 Desa 75-200 User manual Gas Heater 0
5 Desa BG30N User manual Gas Heater 0
6 Desa BG30NT User manual Gas Heater 0
7 Desa BCLP375 User manual Gas Heater 0
8 Desa BG30PT User manual Gas Heater 0
9 Desa 125-RN User manual Gas Heater 0
10 Desa BLP35E User manual Gas Heater 0
11 Desa BVDR18 User manual Gas Heater 1
12 Desa BVDR24 User manual Gas Heater 0
13 Desa BVDR30 User manual Gas Heater 0
14 Desa BVSR18 User manual Gas Heater 0
15 Desa CB36N User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1