Desa GWP20 GWN20T user manual

User manual for the device Desa GWP20 GWN20T

Device: Desa GWP20 GWN20T
Category: Gas Heater
Manufacturer: Desa
Size: 3.3 MB
Added : 6/10/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa GWP20 GWN20T. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa GWP20 GWN20T.

For your convenience

If looking through the Desa GWP20 GWN20T user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa GWP20 GWN20T on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa GWP20 GWN20T to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa GWP20 GWN20T User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa GWP20 GWN20T but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa GWP20 GWN20T. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED (VENT-FREE)
BLUE FLAME GAS HEATER
TM
SAFETY INFORMATION AND INSTALLATION MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
GN30, GP30
GN30T, GP30T
GWN20, GWP20
GWN20T, GWP20T
GWN30T, GWP30T
WMN20, WMP20
WARNING: Improper installation,
WARNING: If the information in this manual is not
adjustment, alteration, service, or
followed exactly, a fire or explosion may result caus-
maintenance can cause injury or
ing property damage, personal injury

Summary of the content on the page No. 2

TABLE OF CONTENTS 2 SAFETY INFORMATION TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 20 LOCAL CODES ........................................................................... 3 SPECIFICATIONS .................................................................... 24 PRODUCT IDENTIFICATION ..................................................... 3 SERVICE HINTS......................................

Summary of the content on the page No. 3

SAFETY INFORMATION 3 LOCAL CODES 3 PRODUCT IDENTIFICATION UNPACKING PRODUCT FEATURES SAFETY INFORMATION PRODUCT Continued IDENTIFICATION Control Knob 4. If you smell gas Ignitor Button • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the fire depart- ment 5. This heat

Summary of the content on the page No. 4

AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation 4 AIR FOR COMBUSTION AND VENTILATION Unusually tight construction is defined as construction WARNING: This heater shall not be installed in a where: confined space or unusually tight construction un- a. walls and ceilings exposed to the outside atmosphere less provisions are provided for adequate combustion have a continuous water vapor retarder with a rating and ventilation air. Read the following instructions to -11 2 of one pe

Summary of the content on the page No. 5

AIR FOR COMBUSTION AND VENTILATION 5 Determining Fresh-Air Flow For Heater Location 5 AIR FOR COMBUSTION AND VENTILATION Continued 4. Compare the maximum Btu/Hr the space can support with the actual DETERMINING FRESH-AIR FLOW FOR amount of Btu/Hr used. HEATER LOCATION __________________ Btu/Hr (maximum the space can support) Determining if You Have a Confined or __________________ Btu/Hr (actual amount of Btu/Hr used) Unconfined Space Example: 51,200 Btu/Hr (maximum the space can support) Use th

Summary of the content on the page No. 6

AIR FOR COMBUSTION AND VENTILATION Ventilation Air 6 AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR 12" Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and Ventilation Grills Into Adjoining Room, one within 12" of the floor on the wall connecting the two spaces Ventilation Option 2 (see options 1 and 2, Figure

Summary of the content on the page No. 7

INSTALLATION 7 Check Gas Type 7 Installation Items Locating Heater INSTALLATION NOTICE: This heater is intended for use as supple- WARNING: Never install the heater mental heat. Use this heater along with your primary • in a bedroom or bathroom heating system. Do not install this heater as your • in a recreational vehicle primary heat source. If you have a central heating • where curtains, furniture, clothing, or other flam- system, you may run system’s circulating blower mable objects are less

Summary of the content on the page No. 8

INSTALLATION Thermostat Sensing Bulb 8 Installing Heater To Wall INSTALLATION Continued THERMOSTAT SENSING BULB Removing Front Panel Of Heater (Thermostat Models Only) 1. Remove the four painted screws, two on each side of front panel. The thermostat sensing bulb has been placed inside the heater for 2. Pull bottom of front panel forward, then out. protection during shipping. 3. Remove any remaining packaging materials. Locating Thermostat Sensing Bulb (for thermostat applications) 1. Remove fro

Summary of the content on the page No. 9

INSTALLATION 9 Installing Heater To Wall (Cont.) 9 INSTALLATION Continued 3. Insert mounting screws through bracket and into wall studs. Marking Screw Locations 4. Tighten screws until mounting bracket is firmly fastened to 1. Tape mounting bracket to wall where heater will be located. wall studs. Make sure mounting bracket is level. Attaching To Wall Anchor Method WARNING: Maintain minimum clearances shown For attaching mounting bracket to hollow walls (wall areas between in Figure 8. If you c

Summary of the content on the page No. 10

INSTALLATION Installing Heater To Wall (Cont.) 10 Mounting Heater To Floor With Optional Floor Kit INSTALLATION Continued Installing Bottom Mounting Screws MOUNTING HEATER TO FLOOR WITH OPTIONAL FLOOR KIT 1. Locate two bottom mounting holes. These holes are near bot- tom on back panel of heater (see Figure 12). Mounting Base Feet to Heater 2. Mark screw locations on wall. 1. Lay heater cabinet on its back on a table with the heater bot- 3. Remove heater from mounting bracket. tom overhanging the

Summary of the content on the page No. 11

INSTALLATION 11 Connecting To Gas Supply 11 INSTALLATION Continued Typical Inlet Pipe Diameters CONNECTING TO GAS SUPPLY 20,000 Btu/Hr Models - 3/8" or greater WARNING: This appliance requires a 3/8" NPT 30,000 Btu/Hr Models - 1/2" or greater (National Pipe Thread) inlet connection to the pres- sure regulator. Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 15

Summary of the content on the page No. 12

INSTALLATION Checking Gas Connections 12 INSTALLATION Continued CHECKING GAS CONNECTIONS Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 16). WARNING: Test all gas piping and connections 2. For natural gas open main gas valve located on or near gas for leaks after installing or servicing. Correct all leaks meter. For propane/LP gas open propane/LP supply tank valve. at once. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from

Summary of the content on the page No. 13

OPERATING HEATER (MANUAL CONTROL MODELS) 13 For Your Safety Read Before Lighting 13 Lighting Instructions OPERATING HEATER 5. Press in control knob and turn counterclockwise MANUAL CONTROL MODELS to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 19). FOR YOUR SAFETY READ Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may BEFORE LIGHTING need to be pressed in for 30 seconds or more. This will al-

Summary of the content on the page No. 14

OPERATING HEATER (MANUAL CONTROL MODELS) To Turn Off Gas To Appliance 14 Manual Lighting Procedure OPERATING HEATER (THERMOSTAT CONTROLLED MODELS) For Your Safety Read Before Lighting Lighting Instructions OPERATING HEATER Continued C. Use only your hand to push in or turn the gas control knob. TO TURN OFF GAS TO APPLIANCE Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- Shutting Off Heater cian or gas supplier. Force or atte

Summary of the content on the page No. 15

OFF HI OPERATING HEATER (THERMOSTAT CONTROLLED MODELS) 15 15 Lighting Instructions (Cont.) Thermostat Control Operation Manual Lighting Procedure INSPECTING HEATER Pilot Flame Pattern OPERATING HEATER Continued Note: The thermostat sensing bulb measures the temperature CAUTION: Do not try to adjust heating levels by of air near the heater cabinet. This may not always agree with using the equipment shutoff valve. room temperature (depending on housing construction, instal- lation location, room

Summary of the content on the page No. 16

INSPECTING HEATER Burner Flame Pattern 16 CLEANING AND MAINTENANCE ODS/Pilot and Burner Cleaning Burner Pilot Air Inlet Cabinet INSPECTING HEATER Continued BURNER FLAME PATTERN ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled WARNING: If yellow tipping occurs, your heater brush to clean. could produce increased levels of carbon monoxide. CLEANING BURNER PILOT AIR INLET The primary air inlet holes allow the proper amount of air to mix with NOTICE: Do not mist

Summary of the content on the page No. 17

TROUBLESHOOTING 17 17 TROUBLESHOOTING WARNING: Turn off and un- CAUTION: Never use a wire, plug heater and let cool before needle, or similar object to clean Note: For additional help, visit DESA servicing. Only a qualified ser- ODS/pilot. This can damage ODS/ International’s technical service web site vice person should service and pilot unit. at www.desatech.com. repair heater. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignit

Summary of the content on the page No. 18

TROUBLESHOOTING 18 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice is clogged 1. Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice 2. Inlet gas pressure is too low 2. Contact local natural or propane/LP gas company Delayed ignition of burner 1. Manifold pressure is too low 1. Contact local natural or propane/LP gas company 2. Burner orifice is clogged 2. Clean burner (see Cleaning and M

Summary of the content on the page No. 19

TROUBLESHOOTING 19 19 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, ci

Summary of the content on the page No. 20

ILLUSTRATED PARTS BREAKDOWN GN30, GP30 GWN20, GWP20, WMN20, WMP20 20 ILLUSTRATED PARTS BREAKDOWN 15 7 GN30, GP30 1 20 GWN20, GWP20 WMN20, WMP20 21 4 22 9 17 12 13 11 10 18 9 14 19 8 16 6 3 5 2 For more information, visit www.desatech.com For more information, visit www.desatech.com 107884


Alternative user manuals
# User manual Category Download
1 Desa 125-R User manual Gas Heater 0
2 Desa BG30P User manual Gas Heater 0
3 Desa 30-80 User manual Gas Heater 0
4 Desa 75-200 User manual Gas Heater 0
5 Desa BG30N User manual Gas Heater 0
6 Desa BG30NT User manual Gas Heater 0
7 Desa BCLP375 User manual Gas Heater 0
8 Desa BG30PT User manual Gas Heater 0
9 Desa 125-RN User manual Gas Heater 0
10 Desa BLP35E User manual Gas Heater 0
11 Desa BVDR18 User manual Gas Heater 1
12 Desa BVDR24 User manual Gas Heater 0
13 Desa BVDR30 User manual Gas Heater 0
14 Desa BVSR18 User manual Gas Heater 0
15 Desa CB36N User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1