White Rodgers 37-5488A user manual

User manual for the device White Rodgers 37-5488A

Device: White Rodgers 37-5488A
Category: Marine Heating System
Manufacturer: White Rodgers
Size: 0.15 MB
Added : 10/4/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers 37-5488A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers 37-5488A.

For your convenience

If looking through the White Rodgers 37-5488A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers 37-5488A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers 37-5488A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers 37-5488A User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers 37-5488A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers 37-5488A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TYPE 8B43A-601
RELAY-HOT WATER CONTROL
WHITE-RODGERS For Use With Line Voltage Primary Control
(Suitable for External Zone Valve Load)
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
These Relay-Hot Water Controls combine into a single
enclosure: a high limit control, low limit-circulator control,
circulator

Summary of the content on the page No. 2

INSTALLATION CONT. WELL CLAMP 3. Insert sensing bulb into well, forming capillary so bulb CONTROL CASE bottoms in well. Raise control onto well, slipping ADAPTOR FLANGE flange on well between back of case and well clamp. WELL ADAPTOR Be sure well fits snugly into hole in case. Then tighten (F71-0924) well clamp screws evenly and securely. Fig. 1 CAUTION CAPILLARY MOUNTING TO EXISTING WELL Do not dent or bend the bulb of the temperature (for types with well adaptor) BULB sensitive element as this

Summary of the content on the page No. 3

ZONING FOR WATER VALVES Connect Z to 1, T1 to 2, and T2 to 3 on water zone valves 3 as shown. Refer to sheet packed with water valves for TO TERMINALS ON T1 complete wiring information. For water valves other than T2 W-R 1311 OR 1361 2 ZONE VALVES White-Rodgers, consult the valve manufacturer for wiring 1 Z1 details. Fig. 4 ZONING WITH CIRCULATORS All wiring should be done in accordance with local and national electrical codes and ordinances. This diagram shows connections for either a line volt

Summary of the content on the page No. 4

COMMANDE À RELAIS POUR EAU CHAUDE TYPE 8B43A-601 À l’usage des commandes principales à la tension du réseau WHITE-RODGERS (Convient aux charges externes de robinets de zone) INSTRUCTIONS D’INSTALLATION Utilisateur : conservez ces instructions pour vous y référer au besoin ! SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D’INSTALLER ET D’UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATÉRIELS. DESCRIPTION La commande à relais pour eau chaude rassemble dans

Summary of the content on the page No. 5

INSTALLATION (suite) SUPPORT DE LA GAINE 3. Introduisez le capteur bien au fond de la gaine en formant BOÎTIER DE LA convenablement le capillaire. Placez la commande sur la REBORD DE COMMANDE L’ADAPTATEUR gaine et glissez le rebord de celle-ci entre l’arrière du boîtier et le support. Assurez-vous que la gaine s’adapte bien juste ADAPTATEUR DE GAINE (F71-0924) dans le trou du boîter. Serrez ensuite solidement et uniformément les vis du support de la gaine. Fig. 1 CAPILLAIRE ATTENTION INSTALLATIO

Summary of the content on the page No. 6

ZONAGE POUR ROBINETS À L’EAU Raccordez Z sur 1, T1 sur 2 et T2 sur 3 du robinet de zone (voir 3 l’illustration). Pour des renseignements de câblage plus complets, référez-vous au feuillet fourni avec le robinet de zone. Dans le VERS LES BORNES DU T1 T2 ROBINET DE ZONE 2 cas de robinets de zoned’un fabricant autre que White-Rodgers, W-R 1311 OU 1361 obtenez les détails de câblage du fabricant. 1 Z1 Fig. 4 ZONAGE A VEC CIRCULA TEURS Tout le câblage doit être conforme aux codes et règlements locaux


Alternative user manuals
# User manual Category Download
1 White Rodgers 37-0883 User manual Marine Heating System 1
2 White Rodgers 37-0882C User manual Marine Heating System 1
3 Bravo! BH -0133 User manual Marine Heating System 1
4 Bravo! Bravo User manual Marine Heating System 0
5 Carrier Performance Series 2 - Stage Heat Pump with Puron Refrigerant 25HPA6 User manual Marine Heating System 4
6 Kambrook KRH300 User manual Marine Heating System 0
7 White Rodgers 37-0883 User manual Marine Heating System 1
8 White Rodgers 37-0882C User manual Marine Heating System 1
9 York GF9 User manual Marine Heating System 0
10 York GM9 User manual Marine Heating System 0
11 York GY9 User manual Marine Heating System 1