Universal 150-FASNG user manual

User manual for the device Universal 150-FASNG

Device: Universal 150-FASNG
Category: Gas Heater
Manufacturer: Universal
Size: 0.36 MB
Added : 9/19/2013
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Universal 150-FASNG. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Universal 150-FASNG.

For your convenience

If looking through the Universal 150-FASNG user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Universal 150-FASNG on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Universal 150-FASNG to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Universal 150-FASNG User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Universal 150-FASNG but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Universal 150-FASNG. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OWNERS MANUAL
FORCED AIR NATURAL GAS CONSTRUCTION HEATER
Model
150-FASNG
QUESTIONS?
MISSING / DAMAGED PARTS
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
http://allpro-heaters.com, or call our Customer
STOP
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.
TABLE OF CONTENTS
HEATER SPECIFICATIONS...

Summary of the content on the page No. 2

Model 150-FASNG HEATER SPECIFICATIONS Type of Gas: For use with Natural Gas Only Gas Supply Pressure to regulator Maximum: Minimum: 5" W.C. (1.25 kPa) 1/2 psig (3.45 kPa) regulator out 4" W.C. (1.0 kPa) Electrical Input: 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 100V Ignition: Direct Spark, interrupted type Primary Flame Control: Solid State, 10-15 Second Timing High Temperature Control: 240°F (116°C) Minimum Ambient Temp. Rating 0°F (-17.8°C) Model: 150-FASNG Rating:

Summary of the content on the page No. 3

Model 150-FASNG OPERATING PRECAUTIONS SAFETY PRECAUTIONS This is a natural gas, direct-fired, forced air heater. It's intended 1.Check the heater thoroughly for damage. DO NOT operate a use is primarily temporary heating of buildings under damaged heater. construction, alteration or repair. 2.DO NOT modify the heater or operate a heater which has been modified from its original condition. If natural gas leaks from a connection or fitting, it mixes with 3.Use only natural gas. the surrounding air

Summary of the content on the page No. 4

Model 150-FASNG ODOR FADE WARNING WARNING heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the Asphyxiation Hazard heater. • Do not use this heater for heating human living quarters. • Lack of proper ventilation air will lead to improper • Do not use in unventilated areas. combustion. • The flow of combustion and ventilation air must not be • Improper combustion can lead to carbon monoxide obstructed. poisoning leading to serious inj

Summary of the content on the page No. 5

Model 150-FASNG OPERATING INSTRUCTIONS SERVICING A hazardous condition may result if a heater is used that has PREPARING FOR OPERATION been modified or is not functioning properly. When the heater is 1.Check the heater for possible shipping damage. If any is working properly: found, immediately notify the factory. * The flame is contained within the heater. 2.Follow all of the "Precautions". * The flame is essentially blue with perhaps some yellow 3.Install plumbing to a low pressure (1/2 psig m

Summary of the content on the page No. 6

150-FASNG PARTS Item Part No. Description Qty. Item Part No. Description Qty. 1 1700 Burner Shell Ass'y 1 21 7095 Handle Ass'y 1 22 6146 Fitting, Reducing Nipple 1 2 6225 Snap Bushing, 5/8" 1 23 6259 Regulator 1 3 1672 Middle Cylinder 1 4 1146 Flame Holder Ass'y 1 24 6125 Fitting, Male Connector 1 5 1083 Spark Plug 1 25 3087 Grill, Inlet 1 6 1216 Orifice Ass'y 1 26 3037 Nut, Spark Plug 3 * 7295 Label, Wiring Diagram 1 7 1741 Control Box Ass'y 1 28 6010 Set Screw 1 8 15

Summary of the content on the page No. 7

MODEL 150-FASNG WIRING DIAGRAM If any original wiring as supplied with the heater must be replaced, it must be replaced with type AWG 105° C wire or its equivalent except as indicated (*type SF2-200, **SGI 250° C). WIRING CHART PART NO. COLOR LENGTH FROM TO 1100 White 7" Valve Terminal Block 1040 Black 6" On/Off Switch Terminal Block 1226 Red (Hi-Temp) 16 1/2" High Limit Switch Valve 1226 Red (Hi-Temp) 16 1/2" High Limit Switch Terminal Block 1070 Orange 11" Flame Control (Ignition) Spark Pl

Summary of the content on the page No. 8

Model 150-FASNG WARRANTY We are pleased that you have selected our product and take the like and no implied warranty arising from course of dealing this opportunity to assure you that qualified service facilities are or usage of trade. This warranty will not apply to any product available if required. With the cooperation of independent which has been repaired or altered outside of the California dealers, a nationwide network of authorized servicing dealers is factory in any respect which in our

Summary of the content on the page No. 9

Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle. Warranty Registration Your Information First Name Last name Mailing Address - City State Postal code E-mail Address <$9,999 $10,000 to $19,999 >$50,000 Annual house hold income before tax $20,000 to $34,999 $20,000 to $34,999 Age of Purchaser <20 years 20-29 years 30-39 years 40-49 years 50-59 years >60 years Fold Here Your Preferences In choosing your heater the following categories were: Male Wh

Summary of the content on the page No. 10

SCHEU PRODUCTS COMPANY, INC ATTN: MARKETING DEPARTMENT 8855 BAKER AVENUE RANCHO CUCAMONGA, CA 91730 Visit our website for product information, technical support, customer service, and warranty registration at: WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.


Alternative user manuals
# User manual Category Download
1 Universal 35-R User manual Gas Heater 0
2 Allied Air Enterprises 506271-01 User manual Gas Heater 0
3 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
4 Breckwell ECONOMY P22FSL User manual Gas Heater 0
5 Breckwell ECONOMY P22FSA User manual Gas Heater 0
6 Breckwell ECONOMY P22I User manual Gas Heater 1
7 Briggs & Stratton 32K400 User manual Gas Heater 2
8 Bryan Boilers CLM240WP User manual Gas Heater 2
9 Bryan Boilers CLM180WP User manual Gas Heater 0
10 Bryan Boilers CLM270WP User manual Gas Heater 1
11 Bryan Boilers CLM300WP User manual Gas Heater 0
12 Bryan Boilers CLM90WP User manual Gas Heater 0
13 Cannon CANTFS-03-NG User manual Gas Heater 0
14 Cannon CANTFS-03-LP User manual Gas Heater 0
15 Bryant 585A/YAC User manual Gas Heater 7