Universal 35-R user manual

User manual for the device Universal 35-R

Device: Universal 35-R
Category: Gas Heater
Manufacturer: Universal
Size: 0.21 MB
Added : 9/19/2013
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Universal 35-R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Universal 35-R.

For your convenience

If looking through the Universal 35-R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Universal 35-R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Universal 35-R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Universal 35-R User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Universal 35-R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Universal 35-R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
Model # 35-R
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
GAS-FIRED INFRA-RED
PORT ABLE CONSTRUCTION HEA TER
DO NOT LEA VE HEA TER UNA TTENDED OR IN OPERA TION WHILE SLEEPING
CYLINDER NOT INCLUDED
GENERAL HAZARD WARNING:
F AILURE TO COMPL Y WITH THE PRECAUTIONS AND INSTRUCTION

Summary of the content on the page No. 2

SPECIFICATIONS VENTILATION MODEL NO. ............ 35-R WARNING GAS TYPE ......... LP-Gas MAX. INLET THIS APPLIANCE IS UNVENTED AND MUST BE PRESSURE. ......... 22 in. w.c. USED ONLY IN A WELL VENTILATED AREA. MIN. INLET PRESSURE .......... 22 in. w.c. The flow of combustion and ventilation air must not be MANIFOLD obstructed. DO NOT use in a tightly enclosed area. Any PRESSURE .......... 21 in. w.c. combustion process requires and consumes oxygen, and may produce carbon monoxide. This heater must

Summary of the content on the page No. 3

The minimum ambient temperature rating for this heater is GENERAL INFORMATION 20 degrees F. A. Your 35-R portable gas-fired infra-red heater comes This heater incorporates a “Tip Over” switch which fully assembled and is tested at the factory for proper automatically shuts off the burner in the event of tipping. gas and input as stated on the nameplate. Ensure that this switch is in the vertical position and is B. Each heater is equipped with a 100% safety shutoff, secured with the screws provid

Summary of the content on the page No. 4

ODOR FADE WARNING WARNING heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the Asphyxiation Hazard heater. • Do not use this heater for heating human living quarters. • Lack of proper ventilation air will lead to improper • Do not use in unventilated areas. combustion. • The flow of combustion and ventilation air must not be • Improper combustion can lead to carbon monoxide obstructed. poisoning leading to serious injury or death. Sy

Summary of the content on the page No. 5

The connection of Model 35-R to an LP-Gas cylinder must CAUTION be made in a well ventilated area using the regulator and hose assembly supplied with the appliance. DO NOT DO NOT PLACE CLOTHING OR attempt to adjust this regulator. It has been preset at the OTHER COMBUSTIBLE factory to provide safe and proper operation of the ATERIALS ON THIS APPLIANCE. appliance. Use a 7/8” open end wrench to connect the POL fitting (supplied with the LP regulator) to the LP-Gas cylinder. Turn the POL nut in a c

Summary of the content on the page No. 6

• Clean the orifice of each burner with a #55 drill bit (for LP-Gas). NOTE: In cases where long runs of gas supply lineshave been installed ahead of the appliance, it may be necessary • Clean the thermocouple lead. to bleed trapped air out of the supply lines before lighting DO NOT operate this heater if any part has been under the burner. New installations generally require bleeding of water. Call a qualified service person to inspect the appliance supply lines. Wait a minimum of five minutes a

Summary of the content on the page No. 7

Tip Over Switch Magnetic Portion of Control Thermocouple Tip Over Switch Adaptor Leads Leads Control Junction Block Adaptor Kit Heater Bottom Figure 4 REPLACEMENT PARTS LIST Tip-Over Switch Arrangement NOTE: The purpose of the tip-over Switch is to stop the flow REF. # ...... ITEM# DESCRIPTION of gas when heater is accidentally knocked over. When and 1 ............. 00333 ........ CONT M-N SS PORT 3/8MPXI/4MP if the heater is knocked over, simply stand heater up. 2 ............. 02455 ........B

Summary of the content on the page No. 8

Gas-Fired Infra-Red Portable Construction Heater • Model # 35-R 13 3 2 9 4 5 12 8 10 1 11 14 6 7 IF SERVICE IS REQUIRED PLEASE DO NOT RETURN THIS APPLIANCE TO YOUR STORE For information regarding service, please call our Toll-Free Number: 1-888-619-7060 Our office hours are 7:00 AM to 4:00 PM, CT Time Zone, Monday through Friday Please include the model number, date of purchase and description of problem in all communication. Operating Instructions and Owner’s Manual 8

Summary of the content on the page No. 9

OPERATING INSTRUCTIONS AND OWNER’S MANUAL Model # 35-R WARNING: USE ONL Y MANUF ACTURER’S REPLACEMENT P AR TS. USE OF ANY OTHER P ARTS COULD CAUSE INJURY OR DEA TH. REPLACEMENT P ARTS ARE ONL Y A V AILABLE DIRECT FROM THE F ACTORY AND MUST BE INST ALLED BY A QUALIFIED SERVICE AGENCY . PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any SCHEU PROUCTS CO. local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll-Free 888-619-7060 E-Mail Addr


Alternative user manuals
# User manual Category Download
1 Universal 150-FASNG User manual Gas Heater 4
2 Allied Air Enterprises 506271-01 User manual Gas Heater 0
3 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
4 Breckwell ECONOMY P22FSL User manual Gas Heater 0
5 Breckwell ECONOMY P22FSA User manual Gas Heater 0
6 Breckwell ECONOMY P22I User manual Gas Heater 1
7 Briggs & Stratton 32K400 User manual Gas Heater 2
8 Bryan Boilers CLM240WP User manual Gas Heater 2
9 Bryan Boilers CLM180WP User manual Gas Heater 0
10 Bryan Boilers CLM270WP User manual Gas Heater 1
11 Bryan Boilers CLM300WP User manual Gas Heater 0
12 Bryan Boilers CLM90WP User manual Gas Heater 0
13 Cannon CANTFS-03-NG User manual Gas Heater 0
14 Cannon CANTFS-03-LP User manual Gas Heater 0
15 Bryant 585A/YAC User manual Gas Heater 7