Summary of the content on the page No. 1
OPERATOR MANUAL &
SERVICE MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
HY-6E(CE) HYPERSTEAM
™
ATMOSPHERIC CONVECTION
STEAMER INTERNATIONAL
· Self-Contained
· Electric Heated
· Capacity: 6 Steamer Pans (305 x 508 x 64mm)
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the containe
Summary of the content on the page No. 2
OM/SM-HY-6E(CE) IMPORTANT — READ FIRST — IMPORTANT THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING: I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS ELECTRICITY AT WORK REGULATIONS HEALTH AND SAFETY AT WORK ACT FIRE PRECAUTIONS ACT LOCAL AND NATIONAL BUILDING REGULATIONS USERS SHOULD BE CONVERSANT WITH THE APPROPRIATE PROVISIO
Summary of the content on the page No. 3
OM/SM-HY-6E(CE) WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. STEAM CAN CAUSE BURNS. WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT. WARNING: ALLOW COOKING CHAMBER TO COOL BEFORE CLEANING. WARNING: CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT. USE SAFE
Summary of the content on the page No. 4
OM/SM-HY-6E(CE) Table of Contents 1.0 EQUIPMENT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.0 INSPECTION AND UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.0 WATER CONDITIONING/REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.0 INSTALLATION AND START-UP INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5.0 OPERATING INSTRUCTIONS .
Summary of the content on the page No. 5
OM/SM-HY-6E(CE) 1.0 - Equipment Description Your Groen HY-6E (CE) HyPerSteam Convection Steamer is designed to give years of service. It has two stainless steel cavities (cooking chambers) which are served by twin, independent atmospheric steam generators which are electrically-heated. A powerful blower circulates the steam in each cavity to increase heating efficiency. Each cavity holds up to three steam table pans (305 x 508 x 64 mm). A 1.5 mm stainless steel case encloses the cavities, th
Summary of the content on the page No. 6
OM/SM-HY-6E(CE) 3.0 - Water Conditioning It is essential to supply the steam generator with 3.2 If your water contains scale-forming minerals, as water that will not form scale. Even though the steam most water does, use a well-maintained water generator is engineered to minimize scale formation, softener. Whether an exchangeable softener scale development depends on the hardness of your cartridge or a regenerating system is chosen, a water and the number of hours the equipment regular exchange
Summary of the content on the page No. 7
OM/SM-HY-6E(CE) 4.0 - Installation and Start-Up WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. CAUTION DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 30 CENTIMETERS OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE). TO AVOID DRAINAGE PROBLEMS
Summary of the content on the page No. 8
OM/SM-HY-6E(CE) WARNING TO AVOID DAMAGE OR INJURY, FOLLOW THE ELECTRICAL SCHEMATIC EXACTLY WHEN CONNECTING THE UNIT. HY-6E (CE) HyPerSteam™ convection steamers operate at 400 Volts (Three Phase) or 230 Volts (One Phase). ELECTRICAL SUPPLY CONNECTIONS Model Voltage Maximum Kw Field Wiring Current Demands 400 - 3 Phase 19 10 AWG 26.5 Amps HY-6E (CE) 230 - 1 Phase 19 4 AWG 72 Amps 4.1.5 Branch Circuit Protection Each conductor must have overcurrent protection. Connections to the unit must be watert
Summary of the content on the page No. 9
OM/SM-HY-6E(CE) 5.0 - Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. 2 When a cook time is set, the unit steams until 5.1 Controls the timer reaches OFF. The steaming stops, a red light comes on and a beeper sounds. Operator controls are on the front right of the unit. The control panel has the following touch pads and indicator lights. (Your controls may have either 3 With the timer turned to the ON position, the unit steams c
Summary of the content on the page No. 10
OM/SM-HY-6E(CE) 5.2.5 Open the door. Remove the pans from the 5.2.6 To shut down the unit, press the ON steamer, using hot pads or oven mitts to protect switch/pad to OFF. The steam generator will your hands from the hot pans. automatically drain. 10 10 OM/SM-HY-6E(CE)
Summary of the content on the page No. 11
OM/SM-HY-6E(CE) 6.0 - Cleaning To keep your HY-6E Steamer in proper working condition/order, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generators and cavities. 6.1 Suggested Tools WARNING 1. Mild detergent DISCONNECT THE POWER SUPPLY 2. Stainless steel exterior cleaner such as Zepper® BEFORE CLEANING THE OUTSIDE OF 3. Steam generator de-liming agent, such as THE STEAMER. Groen Delimer Descaler, Lime-Away® or an equiva
Summary of the content on the page No. 12
OM/SM-HY-6E(CE) 7. Replace fan baffle partition and close door. 6.2.2 Steam Generator and Cooking Chamber The steamer cavity and steam generator may be 8. The cleaning cycle consists of a boiling clean cleaned separately. When cleaning is scheduled, or stage, a soak stage, and a rinse stage. The full if theSERVICE light is on, follow these simple de- cycle takes about 50 minutes to complete. liming instructions. REMEMBER: DON’T ALLOW DE-LIMING AGENTS TO MIX WITH DE- 9. WEAR PROTECTIVE GREASERS.
Summary of the content on the page No. 13
OM/SM-HY-6E(CE) 7.0 - Maintenance The HY-6E Steamer is designed for minimum 2. Inspect the cooking chamber drain to be sure maintenance, and no user adjustments should be it is not blocked. necessary. Certain parts may need replacement after prolonged use. If there is a need for service, 3. Adjust the latch pin to allow for changes that only Groen personnel or authorized Groen might occur as the gasket ages: representatives should perform the work. a. Loosen the lock nut at the base of the Alw
Summary of the content on the page No. 14
OM/SM-HY-6E(CE) 9.0 - Parts List 9.1 External Cabinet and Sheet Metal Key Description Part No. Key Description Part No. 1 Lower Side Panels 125899 9a Door Pin Lock Nut 003823 2 Lower Front Panel 125898 10 Timer Knob 123100 3 Adjustable Table Leg 042505 11 Mylar Overlay Plate 123128 4 Door 094150 12 Vent Pipe 096855 5 Door Handle 070123 13 Upper Right Side Panel 123183 6 Door Gasket 094147 14 Lower Back Panel 096722 7 Left Pan Rack 094148 15 Sink Drain Fitting 099943 8 Blower Cover/Rack 096788 16
Summary of the content on the page No. 15
OM/SM-HY-6E(CE) 9.0 - Parts List 9.2 Cavity Control Section Key Description Part No. Key Description Part No. 1 Top Cover Clip 123150 8 x 1-3/8” Hose Clamp 127525 2 Timer 100983 9 Fan Motor 096740 3 x Door Switch 096857 10 Motor Capacitor 096813 4 Ready Thermostat 088865 11 Cover, Control Panel 119806 5 Steam Port 088874 12 Steamer Control PC Board 119801 5a Steam Port Gasket 099250 13 Transformer/Capacitor Assy 119815 6 x Steam Hose, Top 099952 14 Timer Board 119817 7 x Steam Hose, Bottom 09995
Summary of the content on the page No. 16
OM/SM-HY-6E(CE) 9.0 - Parts List 9.3 Steamer Base Section Key Description Part No. Key Description Part No. 1 Terminal Block 096810 7 Control Transformer 120/208/240 121716 Volt Pri. 24 Volt Sec. 150VA 2 Fuse Block 096809 3 Fuse 20 Amp 071849 8 Hi-Heat Contactor 119811 4 Water Level Probes 070178 9 Harnesses (see pg 21) 5 Heater Assy (with hi limit t-stat) 128697 10 Circuit Breaker, 2 Amp 119836 5a Heater Element 240V 121706 K1/4 Contactor Relay 24 VDC 119814 6 Gasket Heater Element 042366 K2/5
Summary of the content on the page No. 17
OM/SM-HY-6E(CE) 9.0 - Parts List 9.4 Steamer Base - Rear View Key Description Part No. Key Description Part No. 1 Outer Steam Generator 096719 12 Drain Box 096791 2 Inner Steam Generator 096719 13 Drain Box Flap 099213 3 Top Steam Hose 099952 14 Drain Box Cover 096792 4 Bottom Steam Hose 099951 15 Top Cavity Drain Hose 088847 5 Water Inlet Hose 096773 16 Bot. Cavity Drain Hose 088846 6 Water Inlet Hose Clamp 071271 17 Cavity Dr. Hose Clamp 073259 7 Water Inlet Hose Bib 057217 18 Vent Pipe 096855
Summary of the content on the page No. 18
OM/SM-HY-6E(CE) 9.0 - Parts List 9.5 Steamer Motor and Controls Key Description Part No. Key Description Part No. 1 Fan Motor 096740 7 Timer Knob 123100 2 Motor Mounting Plate 094134 8 Door Switch 096857 3 Motor Shaft Seal 096868 9 Steam Port Kit* 118102 4 Motor Insulator 094135 10 -Ready Thermostat 088865 5 Fan 096790 11 -Steam Port Gasket 099250 6 Timer 50 Hz 100983 12 Timer Fastener Nut 101145 *Includes Thermostat and Steam Port Gasket 18 1 OM/SM-HY-6E(CE)
Summary of the content on the page No. 19
OM/SM-HY-6E(CE) 9.0 - Parts List 9.6 Steamer Generator Individual Parts Key Description New Key Description New 1 Steam Generator Weldment 096887 9 Top Steam Hose 099953 2 Right Steam Gen. Insulation* 096896 10 Sink Drain Hose 099915 3 Left Steam Gen. Insulation* 096770 11 Water Inlet Hose 096772 4 Safety Valve 106392 12 Inner Steam Generator Hose 099912 5 Drain Box Spray Nozzle 081670 13 Outer Steam Generator Hose 099911 6 Water Level Probe 070178 14 Condensate Hose 096771 7 Top Cavity Drain Ho
Summary of the content on the page No. 20
OM/SM-HY-6E(CE) 9.0 - Parts List 9.7 Steamer Individual Parts Key Description Part No. Key Description Part No. 1 Heater Element, 240V 121706 7 Water Inlet Valve 3-way 090827 2 Heater Element, Gasket 042366 8 Control Transformer 120/208/240 Volt 121716 Pri. 24 Volt Sec. 150VA 3 High Limit Thermostat 122009 4 Thermostat Clamp 093482 9 Hi-Heat Contactor 119811 5 Water Level Probes 070178 10 Relay, 24V DC Coil (Low Heat) 119814 6 x Heater Assy w/high limit thermostat 128697 x Part Not Shown 20 0