Sub-Zero CTWH36 user manual

User manual for the device Sub-Zero CTWH36

Device: Sub-Zero CTWH36
Category: Blower
Manufacturer: Sub-Zero
Size: 0.69 MB
Added : 8/20/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sub-Zero CTWH36. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sub-Zero CTWH36.

For your convenience

If looking through the Sub-Zero CTWH36 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sub-Zero CTWH36 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sub-Zero CTWH36 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sub-Zero CTWH36 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sub-Zero CTWH36 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sub-Zero CTWH36. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Page 1
MODEL 808331
IN-LINE BLOWER
For use with models CTWH30, CTWH36, IH4227,
W302418, W302718, W362210-482210
READ AND SAVE THESE INSTRUCTIONS
! !
FOR DOMESTIC COOKING ONLY
WARNING WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4. Use an extinguisher ONLY if:
TO PERSONS, OBSERVE THE FOLLOWING:
A. You know you have a Class ABC extinguisher and you already
1. Use this unit only in the manner intended by the manufacturer. If know how to operate it.
you have questions, contac

Summary of the content on the page No. 2

Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 4½” X 18½” Mounting brackets TO 10” ROUND HANGER factory-shipped in TRANSITION KIT BOLT position for ½” ceil- & WASHER ing material. EXTENSION CEILING SPRING JOIST HANGER 10” ROUND (24” centers KIT CHAIN DUCT (INTAKE) shown) HANGER KIT EYE-BOLT 4½” X 18½” TO 10” ROUND HANGER TRANSI- 10” ROUND KIT NUT & Blower factory-shipped TION DUCT WASHER in horizonta

Summary of the content on the page No. 3

Page 3 WIRING WIRING PLATE POSITION BLACK TO TOP / BACK BLACK OF HOUSING VERTICAL GROUND TO POWER CABLE WIRING PLATE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION 120 VAC LINE IN WHITE (from Wiring plate mounts to side or top of housing. TO range WHITE hood) Ventilator can be wired from outside of housing. Use UL approved connectors to wire per local codes. DUCTING OPTIONS MOUNTING OPTIONS BLOWER DISCHARGE POSITIONS ¼-20 hex nuts secure mounting brackets to housing. Loosen and DUC

Summary of the content on the page No. 4

Page 4 ATTACH POWER CORD TO USE AND CARE To clean blower assembly: Remove access panel, unplug blower HOOD from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft Follow wiring instructions packed with range hood, and adhere to cloth and mild soap or detergent to clean blower discharge area and all local and state codes, and the National Electrical Code. wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assem

Summary of the content on the page No. 5

Page 1 MODEL 808332 IN-LINE BLOWER For use with models CTWH30, CTWH36, IH4227, DD30R, DD36R, DD45R, W30-662418, W30-662718, L28-582212, I36-663418 READ AND SAVE THESE INSTRUCTIONS ! ! FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4. Use an extinguisher ONLY if: TO PERSONS, OBSERVE THE FOLLOWING: A. You know you have a Class ABC extinguisher and you already 1. Use this unit only in the manner intended by the manufacturer. If know how to op

Summary of the content on the page No. 6

Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 8” X 12” TO 8” X 12” TO 8” X 12” TO (OUTLET) 10” ROUND 10” ROUND HANGER 10” ROUND TRANSITION KIT BOLT TRANSITION TRANSITION (FEMALE) & WASHER (FEMALE) (MALE) EXTENSION SPRING 10” ROUND DUCT HANGER 10” ROUND (INTAKE) KIT CHAIN DUCT (INTAKE) HANGER KIT EYE-BOLT GRILLE NUT (Install into square 8” X 12” TO holes in housing) 10” ROUND HANGER MOUNTING TRANSITI

Summary of the content on the page No. 7

Page 3 WIRING WIRING PLATE POSITION BLACK TO BLACK EDGE OF HOUSING GROUND TO VERTICAL WIRING PLATE POWER CABLE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION WHITE TO Wiring plate mounts to side or top of housing. WHITE 120 VAC LINE IN (from range hood) DUCTING OPTIONS Ventilator can be wired from outside of housing. BLOWER DISCHARGE POSITIONS Use UL approved connectors to wire per local codes. DUCT DUCT Housing MOVABLE CONNECTOR rotated & mov- CONNECTOR PANEL (outlet) able panel

Summary of the content on the page No. 8

Page 4 ATTACH POWER CORD TO USE AND CARE To clean blower assembly: Remove access panel, unplug blower HOOD from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft Follow wiring instructions packed with range hood, and adhere to cloth and mild soap or detergent to clean blower discharge area and all local and state codes, and the National Electrical Code. wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assem


Alternative user manuals
# User manual Category Download
1 Sub-Zero 808331 User manual Blower 0
2 Sub-Zero W302718 User manual Blower 0
3 Sub-Zero W362210-482210 User manual Blower 0
4 Sub-Zero CTWH30 User manual Blower 0
5 Sub-Zero IH4227 User manual Blower 0
6 Sub-Zero W302418 User manual Blower 1
7 Sub-Zero CTWH36 User manual Cookware 0
8 AEG HG654320NM User manual Blower 2
9 Air King Exhaust Fan AK110 User manual Blower 1
10 Air King Exhaust Fan AK50LS User manual Blower 1
11 Air King AK90 User manual Blower 13
12 Air King Exhaust Fan AK110PN User manual Blower 1
13 Air King Exhaust Fan AK80 User manual Blower 1
14 Air King B1125 User manual Blower 1
15 Air King B600 User manual Blower 1