Summary of the content on the page No. 1
FEATURES
Instruction Manual
Automatic Dispensing Reboil Function
Automatic Dispensing Hot
Water Pot with
One-Touch
Dispense
Multi-temperature Function
5 Temperature Settings
Multi-temp Cleaning Function
selections
Image
208°F For tea, coffee, instant noodle.
194°F Keep warm around 194°F.
Citric
Of
acid
176°F Keep warm around 176°F.
140°F For infant formula.
SP-5016
COOL Water temp will continuously
decrease till cool
* Based on full pot of water. Ambient temperature of 68°F.
Picture explanat
Summary of the content on the page No. 2
Important Safeguards Warning. To prevent possible electric shock and injury: Do not fill READ ALL INSTRUCTIONS BEFORE USE Open lid with caution, do water above not use force. When using an electrical the FULL appliance, basic precautions indicator. Do not cover the should always be followed, SYMBOLS steam outlet. including the following. Attention Do not tilt or move the unit Warning This appliance is intended with the lid Do not disassemble to boil water only. Do not May cause inju
Summary of the content on the page No. 3
Notice Parts Identification Do not use other than Be cautious of hot steam the supplied power when opening the lid. cord. Plug in dedicated Do not add water during socket. the boiling process. Unplug from power Never turn the unit upside source when not in use. down. Be cautious when moving To disconnect, grip and the unit. Always unplug pull plug from from power source. the wall outlet, Unplug power do not pull by cord and wait the cord. for unit to cool During operation, do not d
Summary of the content on the page No. 4
Operating Instructions Adding Water 1. Open lid and add water. 2. Close lid firmly. Opening and closing the lid Removing and attaching the lid To open: press down with thumb To remove: press down on the Release 3. Connect power. and pull latch upwards. button, pull latch and open lid to 45°. 4. Press TEMP SET button. To close: press lid down firmly. To attach: press down on the NOTE: Do not add water Release button and place lid in above the FULL mark. the groove. • Add water when water lev
Summary of the content on the page No. 5
Temperature Setting Re-Boil 5 temperature settings: 208°F, • Cool Setting: unit will boil water To reboil water, press the REBOIL button. Unit will beep and 194 °F, 176 °F, 140 °F, and Cool. then stop heating. Pressing the Re- Boil indicator will lit. boil button will reboil water. •If water temp is 203°F or higher, unit will boil for 3 minutes. •If water temp is below 203°F, unit will bring water back to • If temp setting is changed from To set/change temperature boiling point. lower to high
Summary of the content on the page No. 6
Adding Water Dry Boil • Add water when water level falls within the red section on the Water Level Indicator. • Unit will automatically begin to boil after adding water. If If there is no water or not, press the Reboil button. if water level is low, Dry boil indicator Press Reboil button will flash and unit Add water to begin boiling. will beep 12 times. immediately. Standby Mode Unit will automatically enter Standby mode if no buttons are pressed If unit is in Dry-boil for over a per
Summary of the content on the page No. 7
Cleaning with Citric Acid. Replacing Worn Parts Lid and Body Storage • Wipe clean with damp cloth. When planning not to use for a The rubber gasket on the lid will wear over time and will need to be period of time, clean unit and replaced periodically. Contact Sunpentown (www.spt-usa.com / 909- Power Cord allow unit to dry completely. 468-5288) to purchase replacement gaskets or for instruction to send • Wipe clean with dry, soft cloth. Place unit back in original box in for repair. Filter
Summary of the content on the page No. 8
Troubleshooting PROBLEM CAUSE REMEDY No power Loose power Check connection at connection the unit and socket. Your Guarantee Cannot switch to Water level is too Add water. If this product is found to be faulty as a result of faulty materials or boil / reboil low. workmanship within one year from date of purchase, it will be repaired free of charge. Water cannot be No power Check power dispensed or not connection This guarantee is subject to the following terms: dispensing • Sunpentown must