Cecilware C-2003RG-IT user manual

User manual for the device Cecilware C-2003RG-IT

Device: Cecilware C-2003RG-IT
Category: Coffeemaker
Manufacturer: Cecilware
Size: 0.87 MB
Added : 2/20/2013
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cecilware C-2003RG-IT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cecilware C-2003RG-IT.

For your convenience

If looking through the Cecilware C-2003RG-IT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cecilware C-2003RG-IT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cecilware C-2003RG-IT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cecilware C-2003RG-IT User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cecilware C-2003RG-IT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cecilware C-2003RG-IT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CENTURY 2000-IT, COFFEE BREWING EQUIPMENT


MODELS


C-2003G-IT

C-2003RG-IT

C-2003LG-IT






MANUAL

Specifications

Installation

Operating Instructions

Programming Instructions

Care Maintenance

Adjustments


Parts Identification


Wiring Diagram














Cecilware sells value... Worldwide

43 -05 20th Avenue, Long Island City, NY 11105 TEL: 718-932-1414

Summary of the content on the page No. 2

SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT Volts 120 120 120 Watts 1,800 1,800 1,800 Amps 15 15 15 Wall Outlet (Receptacle) 5-15R 5-15R 5-15R All Brew Centers are single phase with 2 wires plus a ground with cord and plug, except Eport 220V, 1 PH, 50 cycles (UROPEAN). MECHANICAL SPECIFICATIONS MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT Tank Capacity (US gal.) Cups/Brew Cycle 12 12 12 Cups/Hour 120 120 120 Height (includes 2 ½"

Summary of the content on the page No. 3

FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular design and reduced component count for ease of service. 3. Optional Low Water Temperature Lockout to prevent dispensing at water temperatures below an adjustable threshold. 4. Redundant system interlocks for uncompromising user safety. 5. Large two line display for viewing system status on digital display and modifying parameters. 6. In

Summary of the content on the page No. 4

INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP The Brewer is shipped complete with: DESCRIPTION C-2003G-IT C-2003RG-IT C-2003LG-IT Decanters 3 3 3 Funnels with sample Filter pack 1 1 1 WATER HOOK UP The National Sanit

Summary of the content on the page No. 5

PROGRAMMING INSTRUCTIONS TO ACCESS PROGRAMMING: Press Simultaneously Both Buttons TO SCROLL THRU PROGRAMMING FUNCTIONS: Press One Button TO CHANGE OR RESET LED PARAMETER VALUES LIGHTS D:\1-Milt\Labels & Logos\Techno copy.tif CAUTION LCD WINDOW………… HOT WATER NG34A-E POWER WARMER CANCEL LAST BREW BUTTON BUTTONS BUTTON OPERATION The following is a Functional Description of the Single Station Brewer: Modes of Operati

Summary of the content on the page No. 6

MODES OF OPERATION – DESCRIPTIONS CECILWARE Initialization Mode: &&&&& REV #.# The following screen signifies the presence of this mode: Description – This mode is active only during the first few seconds after “power-on”. The purpose of the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number (depicted by “#.#”). SSSSSS DDD K Normal Mode: SSSSSS HH:MMP The following screen signifies the presence of Normal Mode: Descr

Summary of the content on the page No. 7

BREWING DDD K Brewing State MM:SS HH:MMP Description – This screen is displayed when a Brew Cycle is in progress. The time remaining in the Brew Cycle is displayed in the lower left-hand corner of the screen (depicted as “MM:SS”). The Brew Key LED will blink in this state. The Main Warmer is automatically activated upon entry into this state. The Brewing parameters of Brew Size, Dilution, Pre-Infusion, Pulse Brew, and Drip Time are utilized in this state. Refer to the Service Mo

Summary of the content on the page No. 8

SERVICE MODE Description – The main function of Service Mode is to give qualified personnel the ability to configure the system to meet the requirements of each installation. General Conventions (unless otherwise indicated) 1) To enter or exit Service Mode simultaneously depress both the hidden key under the Cecilware Logo (CW Key) and the hidden key under the first letter of the Model Name (MN Key) until the buzzer sounds (approximately two seconds). 2) Depressing the MN Key will

Summary of the content on the page No. 9

INFUSION TIME - OPTIONAL INFUSION TIME ## SECONDS Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into the grinds during the Pre-Infusion process. SOAK TIME – OPTIONAL SOAK TIME ## SECONDS Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusion period and the beginning of brewing. PULSE BREW - OPTIONAL PULSE BREW ON/OFF Description – The Pulse Brew feature gives the user

Summary of the content on the page No. 10

WARMER TIMER WARMER TIMER ON/OFF Description – The Warmer Timer feature allows the user to set the maximum length of time a brew remains fresh while being warmed. Once the Warmer Timer has expired an alarm is generated. An alarm consists of a blinking warmer LED and (optionally) the audible alarm (buzzer) sounding. The Warmer Timer is reset (restarted) by cycling the warmer Off and On. AUDIBLE ALARM AUDIBLE ALARM ON/OFF Description – The Audible Alarm feature allows the user to enable

Summary of the content on the page No. 11

ADJUST SECONDS ADJUST SECONDS DAY HH:MM:## Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock Seconds placeholder. ADJUST MINUTES ADJUST MINUTES DAY HH:##:SS Description – The Adjust Minutes function allows the user to adjust (set) the systems Real-Time-Clock Minutes placeholder. ADJUST HOURS ADJUST HOURS DAY ##:MM:SS Description – The Adjust Hours function allows the user to adjust (set) the systems Real-Time-Clock Hours placeholder.

Summary of the content on the page No. 12

ERROR MODE Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” using the Power Key located on the membrane keypad to reset any reported error. KEYPAD ! SYSTEM ERROR ! KEYPAD Description – This screen is displayed and the unit is disabled when a key-press is detected during the initial application of power to the system. This test is not performed during a Power Key initiated “power-on” sequence. Pos

Summary of the content on the page No. 13

C-2003G-IT FRONT OPEN VIEW 1 18 2 17 5 4 3 16 15 14 13 12 11 6 10 7 8 9 13

Summary of the content on the page No. 14

TOP CABIN OPEN VIEW 19 20 32 31 30 21 22 24 25 26 23 27 28 29 14

Summary of the content on the page No. 15

PARTS IDENTIFICATION FOR C-2003G-IT, C-2003LG-IT, C-2003RG-IT ITEM SPARE P/N QTY DESCRIPTION PARTS 1 * NG34A 1 TOUCH PAD LABEL: C-2003G-IT, C-2003LG-IT, C-2003RG-IT 2 * L616A 1 THERMISTER PROBE 3 * L615A 1 TRIAC 25 AMPS P182A 2 SCREW F/ TRIAC K624A 1 HEATSINK, F/TRIAC, COPPER P301A 2 WINGED NUT F/ HEATSINK 4 M483A 1 SILICONE HOSE ( .312”ID x 20”L) TANK DRAIN 5 R958A 1 FRONT COVER 6 * L069A 1 POWER SWITCH 7 * C396Q 1 FUSE HOLDER ASS’Y 8 C032A 1

Summary of the content on the page No. 16

TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1. a) Loose wire connection. a) Check wire connections to Relay. See Power Safety Relay Test. No power to the b) Inoperative Power Safety Relay b) Replace Power Safety Relay, if inoper

Summary of the content on the page No. 17

SPECIAL COMPONENTS TEST AND ADJUSTMENTS 1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this test a few times. The

Summary of the content on the page No. 18

5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves. Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed. Replace The Valve Into The Tank And Refill tank. The SINGLE DISPENSE VALVE is factory adjusted to dispense 0.35 oz./sec. of water during the brew cycle (spray duration). TO ADJUST WATER FLOW RATE: Lo

Summary of the content on the page No. 19

FILL DUMP 2 4 6 8 10 12 14 16 18 20 22 SOLENOID HTR HTR HTR VALVE J2 1 3 5 7 9 11 13 15 17 19 21 120VAC 120VAC +- +++ + ++ + + #2 #1 #3 #2 #1 100W 100W 100W CONTROL BOARD L669A 3 1- SAFETY OVERFLOW 2 46 8 10 12 14 16 18 RELAY J1 K1 1 35 7 911 13 15 17 HOSE THER- B203A + + + + + MISTOR LEVEL 4 2+ L617A PROBE TEE ASS'Y K681A TANK HEATER G FUSE 6 AMP MT2 MT1 L1 S1 POWER 8VAC C1 SWITCH 120V 120VAC SP1 0.1uf INPUT 275V


Alternative user manuals
# User manual Category Download
1 Cecilware APT18WT User manual Coffeemaker 1
2 Cecilware BC1 User manual Coffeemaker 0
3 Cecilware FE75N User manual Coffeemaker 0
4 Cecilware JAVA 2-QB User manual Coffeemaker 1
5 Cecilware Ground Coffee Dispensers User manual Coffeemaker 0
6 Cecilware Java Self Serve User manual Coffeemaker 0
7 Cecilware BT-2A 2 24 " 29 lbs User manual Coffeemaker 0
8 Cecilware BC302 User manual Coffeemaker 1
9 Cecilware CL100N User manual Coffeemaker 0
10 Cecilware C-2003LG-IT User manual Coffeemaker 0
11 Cecilware CL75N User manual Coffeemaker 0
12 Cecilware CH100N User manual Coffeemaker 4
13 Cecilware CH75N User manual Coffeemaker 4
14 Cecilware BT-3 3 25" 27 lbs. User manual Coffeemaker 0
15 Cecilware ICAP1-P User manual Coffeemaker 1
16 Philips coffee maker flavor select HD7606 User manual Coffeemaker 3
17 Sony WALKMAN D-EJ2000 User manual Coffeemaker 19
18 Philips HD 7820/65 User manual Coffeemaker 62
19 Philips coffee maker flavor select HD7612 User manual Coffeemaker 91
20 Philips HD7544 User manual Coffeemaker 8