Siemens CZM-4 user manual

User manual for the device Siemens CZM-4

Device: Siemens CZM-4
Category: Smoke Alarm
Manufacturer: Siemens
Size: 0.2 MB
Added : 7/19/2014
Number of pages: 2
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens CZM-4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens CZM-4.

For your convenience

If looking through the Siemens CZM-4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens CZM-4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens CZM-4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens CZM-4 User manual - Online PDF
Advertisement
« Page 1 of 2 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens CZM-4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens CZM-4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CZM-4
Conventional Zone Module
• Four Conventional Initiating Device Circuits
• Supports the Use of:
30 Two Wire Photo or Ion Detectors Per Circuit
Projected Beam Detector (Limit 1 Per Circuit)
Unlimited Shorting Devices
Detector Relay Bases
Audible Bases
Remote Indicator Lamps
• Class A (Style D)
• Class B (Style B)
• On-Board Microprocessor
• 32 Character Custom Alphanumeric Message
Per Circuit
• Optional Alarm Verification by Circuit
• Walk Test by Circuit
• Circuits Power Limited per NEC 760

Summary of the content on the page No. 2

Electrical Specifications Dimensions Electrical Connections 1. Initiating device circuits: Voltage range 20-24.5 VDC Supervisory current 4mA max. capacitor EOL 9mA max. resistor EOL Alarm current 180mA max. per zone 2. Initiating devices per zone: Up to 30 detectors, any combination of those in No. 3 below. Up to five waterflow switches may be used. Any number of direct shorting devices may be used. Wiring may be Style D (Class A) or Style B (Class B). 3. The UL identifiers for compatibility ar


Alternative user manuals
# User manual Category Download
1 Siemens IP-Module CFVA-IP User manual Smoke Alarm 5
2 Siemens Synova FC330A User manual Smoke Alarm 1214
3 Siemens FC700A User manual Smoke Alarm 332
4 Siemens FP-11 User manual Smoke Alarm 47
5 Adobe CS3 User manual Smoke Alarm 1
6 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
7 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
8 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
9 ADT Security Services Unimode 9600 User manual Smoke Alarm 7
10 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
11 Aico Ei166RC User manual Smoke Alarm 12
12 Aico Carbon Monoxide Alarm Ei 225EN User manual Smoke Alarm 40
13 Aico Ei161RC User manual Smoke Alarm 5
14 Aico Ei169RF User manual Smoke Alarm 1
15 Aico Ei168RC User manual Smoke Alarm 14