Bunn VP17A user manual

User manual for the device Bunn VP17A

Device: Bunn VP17A
Category: Coffeemaker
Manufacturer: Bunn
Size: 0.97 MB
Added : 4/24/2014
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bunn VP17A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bunn VP17A.

For your convenience

If looking through the Bunn VP17A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bunn VP17A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bunn VP17A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bunn VP17A User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bunn VP17A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bunn VP17A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
BUNN
VP17A
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
10860.0001C 9/00 ©1997 Bunn-O-Matic Corporation

Summary of the content on the page No. 2

INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It is only for indoor use on a sturdy counter or shelf. WARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition: 1.) Bunn warrants electronic circuit and/or control boards to be commercially free from defe

Summary of the content on the page No. 3

USER NOTICES (cont.) # 00658.0000 #00831.0000 # 02763.0000 10860.1 091300 Page 3

Summary of the content on the page No. 4

ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. The brewer requires 2-wire, grounded service rated 220 - 240 volts ac, 20 amp, single phase, 50 Hz. An all pole disconnect means must be incorporated in the fixed wiring according to local wiring regulations. Proceed as follows: ELECTRICAL HOOK-UP CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service

Summary of the content on the page No. 5

CLEANING 1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. 2. Check and clean the sprayhead. The sprayhead holes must always remain open. 3. With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. When inserted properly, no more than two inches of spring should be visible. Saw back and forth five or six times. NOTE – In hard water areas, this may need

Summary of the content on the page No. 6

TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • This brewer is heated at all times. Keep away from combustibles. WARNING – • Exercise extreme caution when servicing electric

Summary of the content on the page No. 7

TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming 1. Lime Build-up Inspect tank assembly for exces- CAUTION - Tank and tank compo- sive lime deposits. Delime as re- nents should be delimed regularly quired. depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks. 2. Control Thermostat Refer to Service - Control Ther- mostat for testing procedures. See page 10 Dri

Summary of the content on the page No. 8

TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY ® Weak beverage (cont.) 4. Funnel Loading The BUNN paper filter must be centered in the funnel and the bed of grounds leveled by gentle shak- ing. 5. Water Temperature Place an empty funnel on an empty dispenser beneath the sprayhead. Initiate a brew cycle and check the water temperature immediately be- low the sprayhead with a ther- mometer. The reading should not be less than 195°F (91˚C). Adjust the control thermostat to increase the water

Summary of the content on the page No. 9

Contents SERVICE This section provides procedures for testing and Control Thermostat............................................. 10 replacing various major components used in this ON/OFF Warmer Switch ...................................... 11 brewer should service become necessary. Refer to Tank Heater ....................................................... 12 Troubleshooting for assistance in determining the Thermal Cut-Offs ................................................ 13 cause of any pro

Summary of the content on the page No. 10

SERVICE (cont.) 7. Voltage must not be present when the thermostat is turned to the "OFF" position. CONTROL THERMOSTAT If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermostat is operating properly. If voltage is not present as described, replace the thermostat. Removal and Replacement: 1. Remove wires from control thermostat. 2. Remove the thermostat capillary bulb by firmly pulling up on the capillary at the tank lid

Summary of the content on the page No. 11

SERVICE (cont.) If voltage is present as described, reconnect the red ON/OFF WARMER SWITCH wire and proceed to #5. If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness. 5. With the black wire removed, remove the wire from the lower terminal. 6. Check for continuity across the center and lower terminal with the switch in the "ON" (upper) posi- tion. Continuity must not be present when the switch is in the "OFF" (lower) position. ONE WARMER If

Summary of the content on the page No. 12

4. Remove sprayhead and the hex nut securing the SERVICE (cont.) sprayhead tube to the hood. Set aside for reas- TANK HEATER sembly. 5. Remove the eight #8-32 nuts securing the tank lid to the tank. 6. Remove the tank lid with sprayhead tube and tank heater. 7 Remove the two hex nuts securing the tank heater to the tank lid. Remove tank heater with gaskets and discard. 8. Install new tank heater with gaskets on the tank lid and secure with two hex nuts. 9. Install tank lid with sprayhead tube a

Summary of the content on the page No. 13

SERVICE (cont.) Removal and Replacement: THERMAL CUT-OFFS 1. Disconnect the thermal cut-off from the terminal on the black lead from ready light harness and the black lead from the control thermostat or the tank heater terminal and the red lead from the main harness. 2. Remove the white lead from the tank "keep warm" heater from the thermal cut-off terminal. 3. Install new thermal cut-off. 4. Refer to Fig. 9 when reconnecting wires. BLK Lead BLK Lead from Control Thermostat P1262 Thermal Cut-Off

Summary of the content on the page No. 14

SERVICE (cont.) wire, and red/white, brown/black or violet wires on the WARMER ELEMENT(S) warmer element. If continuity is not present as described, replace the warmer element. Removal and Replacement: 1. Remove the three #4-40 screws securing the warmer assembly to the brewer. 2. Lift the warmer assembly from the brewer. 3. Disconnect the two wires from the warmer ele- ment terminals. 4. Remove the two #8-32 nuts securing the warmer element to the warmer plate. 5. Securly install new warmer el

Summary of the content on the page No. 15

10860.1 091300 Page 15

Summary of the content on the page No. 16

10860.1 091300 Page 16

Summary of the content on the page No. 17

10860.1 091300 Page 17


Alternative user manuals
# User manual Category Download
1 Bunn AUTOMATIC CEZF15 User manual Coffeemaker 6
2 Bunn 5S User manual Coffeemaker 0
3 Bunn CWT15 User manual Coffeemaker 12
4 Bunn CEZF User manual Coffeemaker 0
5 Bunn AutoPOD User manual Coffeemaker 3
6 Bunn A10 Automatic User manual Coffeemaker 41
7 Bunn IMIX-4 User manual Coffeemaker 0
8 Bunn 1.5 GALLON User manual Coffeemaker 6
9 Bunn 120/208V User manual Coffeemaker 17
10 Bunn 10 Cup Pourover Coffee Brewer A10 User manual Coffeemaker 20
11 Bunn CDBC-TSR User manual Coffeemaker 0
12 Bunn 12 CUP AUTOMATIC COFFEE BREWER RL35 User manual Coffeemaker 7
13 Bunn 37614 041410 User manual Coffeemaker 3
14 Bunn COFFEE BREWERNHB User manual Coffeemaker 2
15 Bunn AXIOM BREWWISE 39131.0004B User manual Coffeemaker 45
16 Philips coffee maker flavor select HD7606 User manual Coffeemaker 3
17 Sony WALKMAN D-EJ2000 User manual Coffeemaker 19
18 Philips HD 7820/65 User manual Coffeemaker 62
19 Philips coffee maker flavor select HD7612 User manual Coffeemaker 91
20 Philips HD7544 User manual Coffeemaker 8