Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 user manual

User manual for the device Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125

Device: Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125
Category: Patio Heater
Manufacturer: Roberts Gorden
Size: 12.7 MB
Added : 2/23/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125.

For your convenience

If looking through the Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Roberts Gorden Gas-Fired, Low Intensity Unitary Heater Designed for Harsh Environments HE-125. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance.
®
3. DO NOT use electrical switches.
4. DO NOT use any telephone in
your building.
5. Extinguish any open flame.
Vantage HE
6. Leave the building.
7. Immediately call your local gas
supplier after leaving the building.
Follow the gas supplier’s
instructions.
Gas-Fired, Low Intensity
8. If you cannot reach your gas
supplier, call the Fire Department.
Unitary Heater Designed for
WARNING
Ha

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS SECTION 1: Heater Safety......................................................1 8.12 Outside Combustion Air Supply............................... 40 1.1 Manpower Requirements .............................................1 SECTION 9: Gas Piping........................................................ 43 1.2 Safety Labels and Their Placement .............................1 SECTION 10: Wiring.............................................................. 45 1.3 California Proposition

Summary of the content on the page No. 4

Summary of the content on the page No. 5

TABLE OF FIGURES Figure 1: Top and Bottom Panel Label Placement ....................2 Figure 2: Side and Back Panel Label Placement......................3 Figure 3: Standard Reflector ....................................................7 Figure 4: One Side Reflector....................................................7 Figure 5: Two Side Reflectors ..................................................7 Figure 6: 45° Tilt Reflector .......................................................8 Figure 7

Summary of the content on the page No. 6

Summary of the content on the page No. 7

SECTION 1: HEATER SAFETY SECTION 1: HEATER SAFETY Your Safety is Important to Us! 1.1 Manpower Requirements This symbol is used throughout To prevent personal injury and damage to the heater, the manual to notify you of possi- two persons will be required for installation. ble fire, electrical or burn hazards. 1.2 Safety Labels and Their Placement Please pay special attention when Product safety signs or labels should be replaced by reading and following the warn- the product user when th

Summary of the content on the page No. 8

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL FIGURE 1: Top and Bottom Panel Label Placement Logo Label Rating Plate Label Bottom Panel Proposition 65 Label Top Panel Description Part Number Logo Label 91013201 Rating Plate Label 91010401 Gas Connection Label 91018122 Proposition 65 Label 91070015 2

Summary of the content on the page No. 9

SECTION 1: HEATER SAFETY FIGURE 2: Side and Back Panel Label Placement Control Side Panel Clearances to Combustibles Label Control Side Panel (Inside) Wiring Label Vent Length Label Back Panel Lighting Instruction Plate Label Description Part Number Clearances to Combustibles Label 91013415 Wiring Label 91013300 Vent Length Label 91039500 Lighting Instruction Plate Label 91029602 3

Summary of the content on the page No. 10

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 2: INSTALLER RESPONSIBILITY The installer is responsible for the following: system which minimizes the lateral movement or swing which might damage reflectors. See Page � To install the heater, as well as the gas and elec- 17, Figure 15. trical supplies, in accordance with applicable specifications and codes. Roberts-Gordon LLC �Washbays/car washes: The heater must not be recommends the installer contact a Local Building exposed to

Summary of the content on the page No. 11

SECTION 2: INSTALLER RESPONSIBILITY 2.2 Corrosive Chemicals CAUTION Product Damage Hazard Do not use heater in area containing corrosive chemicals. Refer to appropriate Material Safety Data Sheets (MSDS). Failure to follow these instructions can result in product damage. Roberts-Gordon LLC cannot be responsible for ensuring that all appropriate safety measures are undertaken prior to installation; this is entirely the responsibility of the installer. It is essential that the contractor,

Summary of the content on the page No. 12

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 3: CLEARANCES TO COMBUSTIBLES � Maintain clearances from swinging and overhead doors, overhead cranes, vehicle lifts, partitions, 3.1 Required Clearances to Combustibles storage racks, hoists, building construction, etc. WARNING � In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to the com- bustibles.

Summary of the content on the page No. 13

SECTION 3: CLEARANCES TO COMBUSTIBLES NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows. 2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect. FIGURE 3: STANDARD REFLECTOR (inches) (centimeters) Model A B CDA BC D HE-40 6 27 53 27 16 69 135 69 HE-60 6 35 63 35 16 89 161 89 HE-80 6 38 66 38 16 97 168 97 HE-100 6 40 71 40 16 102 181 102 HE-125 6 46 77 46 16 117 196 117 HE-150 6 50 80 50

Summary of the content on the page No. 14

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows. 2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect. FIGURE 6: 45° TILT REFLECTOR (inches) (centimeters) Model A BC DA BC D HE-40 8 8 51 46 21 21 130 117 HE-60 8 8 60 54 21 21 153 138 HE-80 8 8 66 60 21 21 168 153 HE-100 10 8 74 64 26 21 188 163 HE-125 10 8 78 69 26 21 199 176 HE-150

Summary of the content on the page No. 15

SECTION 3: CLEARANCES TO COMBUSTIBLES NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows. 2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect. FIGURE 9: U-TUBE, OPPOSITE 45° REFLECTOR (inches) (centimeters) Model A BC DA BC D  - UNAPPROVED - HE-40 - UNAPPROVED - HE-60 8 54 60 22 21 138 153 56 HE-80 8 60 66 22 21 153 168 56    HE-100 10 64 74 22 26 163 188 56 HE-125 10 70 78 22 26

Summary of the content on the page No. 16

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows. 2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect. FIGURE 12: VENTING (inches) (centimeters) Model A E F A E F   HE-40 14 18 18 36 46 46   HE-60 141818364646   HE-80 20 24 18 51 61 46    HE-100 20 24 18 51 61 46 HE-125 20 24 18 51 61 46   HE-150

Summary of the content on the page No. 17

SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES 4.1 Gas Codes 4.3 Public Garages The type of gas appearing on the nameplate Installation in garages must be in accordance must be the type of gas used. Installation must with the following codes: comply with national and local codes and United States: Refer to Standard for Parking requirements of the local gas company. Structures NFPA 88A - latest revision or the United States: Refer to

Summary of the content on the page No. 18

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL SECTION 5: MAJOR COMPONENTS FIGURE 13: Major Component Descriptions Burner with Tube Gasket Reflector Must be installed with the (Stainless Steel flame observation or Aluminum) window facing down. Alternate overlap as shown on overview and on Page 19, Figure 17. Minimum overlap is 6" (16 cm). Vent Cap Tube Burner Tube Attach at flue end Heat Treated Supplied in 10' and air inlet with Aluminized tube supplied (3 m) lengths. Burner t

Summary of the content on the page No. 19

SECTION 5: MAJOR COMPONENTS 5.1 Standard Parts List Table 1: Contents of Heater Burner Carton Part No. Description HE-40 HE-60 HE-80 HE-100 HE-125 HE-150 HE-175 032XXXXX Burner Assembly (Rate and Fuel Varies) 1 1 1 1 1 1 1 02568200 Gasket (Burner to Burner Tube) 1 1 1 1 1 1 1 132100NA Installation, Operation and Service Manual 1 1 1 1 1 1 1 94273914 Hex Head Bolts 5/16-18 Rolok 4 4 4 4 4 4 4 96411600 Split Lock washer 4 4 4 4 4 4 4 91221100 Nipple 1/2" NPT x 4" Galv. 1 1 1 1 1 1 1 91317300 1/4

Summary of the content on the page No. 20

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL Table 3: Component Package Guide Core and Extension Packages Model Tubing Length Aluminized Stainless Steel HE-40 10' (3 m) CP10ALUM CP10ALUMSS HE-60 20' (6 m) CP20ALUM CP20ALUMSS HE-80 20' (6 m) CP20ALUM CP20ALUMSS HE-100 30' (9 m) CP30ALUM CP30ALUMSS HE-125 40' (12 m) CP40ALUM CP40ALUMSS HE-150 50' (15 m) CP30ALUM + EXP20ALUM CP30ALUMSS+ EXP20ALUMSS HE-175 60' (18 m) CP30ALUM + EXP30ALUM CP30ALUMSS + EXP30ALUMSS Table 4: Accessories Package


Alternative user manuals
# User manual Category Download
1 Roberts Gorden Compact Tubular Unit Heaters CTCU 11 User manual Patio Heater 0
2 Roberts Gorden Blackheat UHA-Series 60 User manual Patio Heater 0
3 Roberts Gorden Compact Tubular Unit Heaters CTCU 15 User manual Patio Heater 0
4 Roberts Gorden Blackheat UHA-Series 45 User manual Patio Heater 0
5 Roberts Gorden Compact Tubular Unit Heaters CTCU 22 User manual Patio Heater 0
6 Roberts Gorden Blackheat UHA-Series 125 User manual Patio Heater 1
7 Roberts Gorden Blackheat UHA-Series 30 User manual Patio Heater 0
8 Roberts Gorden Compact Tubular Unit Heaters CTCU 27 User manual Patio Heater 0
9 Roberts Gorden Blackheat UHA-Series 75 User manual Patio Heater 0
10 Roberts Gorden Compact Tubular Unit Heaters CTCU 32 User manual Patio Heater 0
11 Roberts Gorden Combat Cabinet Heaters POP-ECA/PGP-ECA 015 to 0100 User manual Patio Heater 17
12 Roberts Gorden Compact Tubular Unit Heaters CTCU 7 User manual Patio Heater 0
13 Roberts Gorden Gas-Fired, Low Intensity Unitary Heater CTH2-100 User manual Patio Heater 0
14 Roberts Gorden Gas-Fired, Low Intensity Unitary Heater CTH2-125 User manual Patio Heater 0
15 Roberts Gorden Gas-Fired, Low Intensity Unitary Heater CTH2-175 User manual Patio Heater 0
16 Blue Rhino 163000 User manual Patio Heater 0
17 Blue Rhino 450000 User manual Patio Heater 0
18 Blue Rhino Charmglow 200605 User manual Patio Heater 5
19 Blue Rhino 223600 User manual Patio Heater 1
20 Blue Rhino 200209-450000 User manual Patio Heater 1