Procom ML150TPA user manual

User manual for the device Procom ML150TPA

Device: Procom ML150TPA
Category: Gas Heater
Manufacturer: Procom
Size: 3.62 MB
Added : 3/29/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Procom ML150TPA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Procom ML150TPA.

For your convenience

If looking through the Procom ML150TPA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Procom ML150TPA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Procom ML150TPA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Procom ML150TPA User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Procom ML150TPA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Procom ML150TPA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

IMPORTANT 10. Before using furniture polish, WARNING SAFETY INFORMATION wax, carpet cleaner, or similar Modeles ML150HPA, ML150TPA, IMPORTANT: Read this products, turn heater off. If ML250HPA, ML250TPA are equipped owner’s manual carefully and heated, the vapors from these for propane gas. Field conversion is completely before trying to not permitted. products may create a white assemble, operate, or service this heater. Im

Summary of the content on the page No. 3

PRODUCT FEATURES Figure1-Vent-Free Propane/LP Gas Heater SAFETY DEVICE LOCAL CODES A standard requirement for all vent-free room Install and use heater with care. Follow all local heaters. This heater has a pilot with an Oxygen codes. In the absence of local codes, use the Depletion Sensor(ODS) safety shutoff system. latest edition of National Fuel Gas code ANSI Z223.1, The ODS/pilot shuts off the heater if there is also known as NFPA 54*. not eno

Summary of the content on the page No. 4

Unusually Tight Construction Confined and FRESH AIR FOR The air that leaks around doors and Unconfined Space COMBUSTION AND windows may provide enough fresh The National Fuel Gas Code ANSI VENTILATION air for combustion and ventilation. Z223.1 defines a confined space However, in buildings of unusually as a space whose volume is less WARNING: This heater tight construction, you must provide than 50 cubic feet per 1,000 Btu per shall not be

Summary of the content on the page No. 5

3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Example: Gas furnace Btu/Hr Gas water heater 40,000 Btu/Hr Vented gas heater Btu/Hr Vent free heater + 18,000

Summary of the content on the page No. 6

VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3. Air for Combustion and Ventilation for required s

Summary of the content on the page No. 7

INSTALLATION FASTENING HEATER TO WALL Attaching to Wall Anchor: This WARNING: Maintain the Mounting Bracket method allows you to attach minimum clearances shown The mounting bracket is located mounting bracket to hollow walls in Figure 4. If you can, on back panel of heater (see (wall areas between studs) or to provide greater clearances from figure 6). It has been taped there solid walls (concrete or masonry). floor, ceiling, and joi

Summary of the content on the page No. 8

INSTALLATION Attaching Mounting Bracket to IMPORTANT: Do not Wall hammer key! For thick walls Note: Wall anchors, mounting (over 1/2" thick) or solid walls, screws, and spacers are in do not pop open wings. hardware package. The hardware package is provided with heater. Attaching to Wal l Stud Method Figure 12 - Installing Bottom For attaching mounting bracket to Mounting Screws wall studs 1. Drill holes at marked lo

Summary of the content on the page No. 9

INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect r heater to gas supply. Follow all local codes. WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/

Summary of the content on the page No. 10

OPERATING YOUR HEATER INSTALLATION NON-THERMOSTAT MODELS CHECKING GAS Pressure Testing Heater Gas Connections CONNECTIONS nFOR YOUR SAFETYn WARNING: Test all gas READ BEFORE LIGHTING 1. Open equipment shutoff valve piping and connections for leaks (see Figure 15). after installing or servicing. Correct WARNING: If you do not 2. Open propane/LP supply tank all leaks at once. follow these instructions exactly, valve. a fire

Summary of the content on the page No. 11

OPERATING YOUR HEATER Slightly press in control knob and turn counterclockwise to the Manual Control Models LOW,MEDIUM, or HIGH position nLIGHTINGn (see Figure 19). INSTRUCTIONS IMPORTANT: Release downward 1. STOP! Read the safety pressure while turning control knob. information on the side of Control knob will lock at the desired heater. position. 2. Check that gas supply to Figure 17 - Control Knob in The nTO TURN OFFn heater is

Summary of the content on the page No. 12

OPERATING YOUR HEATER a qualified service person or gas nLIGHTINGn supplier for repairs. THERMOSTAT MODELS INSTRUCTIONS Note: If pilot goes out, repeat 1. STOP! Read the safety nFOR YOUR SAFETYn steps 3 through 7. This heater information on the side of heater. READ BEFORE LIGHTING has a safety interlock system. 2. Make sure equipment shutoff Wait one(1)minute before lighting valve is fully open. WARNING:

Summary of the content on the page No. 13

OPERATING HEATER Continued CLEANING ODS/PILOT AND nTHERMOSTATn BURNER CONTROL OPERATION l Use a vacuum cleaner, The thermostatic control used on pressurized air. or small, soft these Models differs from standard bristled brush to clean. Figure 23 - Correct Pilot Flame thermostats.Standard thermostats sim- ply turn on and off the burner. The Pattern CLEANING BURNER thermostat used on this heater PILOT AIR INLET HOLE senses the room temperatu

Summary of the content on the page No. 14

TROUBLESHOOTING Note : All troubleshooting WARNING: Only a qualified CAUTION: Never use a wire, items are listed in order of needle, or similar object to clean service person should service and operation. ODS/pilot. This can damage repair heater. ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed and 1. Ignitor electrode is positioned 1. Replace ignitor. control knob is pressed in and turned to wrong.

Summary of the content on the page No. 15

TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner(s)does not light after 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning ODS/pilot is lit. and Maintenance, Page 13) or replace burner orifice. 2. Burner orifice diameter is too small. 2. Replace burner orifice. 3. Inlet gas pressure is too low. 3. Contact local Propane/LP gas company. Delayed ignition of burner(s). 1. Manifold pressure is too low. 1. Con

Summary of the content on the page No. 16

TROUBLESHOOTING Continued WARNING: If you smell gas l Shut off gas supply. l Do not try to light any appliance. l Do not touch any electrical switch; do not use any phone in your building. l Immediately cal l your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. l If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Clean- i

Summary of the content on the page No. 17

SPECIFICATIONS ML150TPA ML250HPA ML250TPA ML150HPA 15,000 6,000/25,000 25,000 6,000/15,000 Btu(available) Propane/LP Only Propane/LP Only Propane/LP Only Propane/LP Only Gas Type Piezo Piezo Piezo Piezo Ignition 10" W.C. 10" W.C. 10" W.C. 10" W.C. Pressure Regulator setting Inlet Gas Pressure (inches of water) 14" 14" 14" 14" Maximum 11" 11" 11" 11" Minimum Dimensions, Inches (HxWxD) 23 1/2 19 1/4 8 23 1/2 26 5/8 8 23 1/2 26 5/8 8 23 1/2×19 1/4×8 × × × × × × Heater 26 1/2 21 3/4 9 1/4 26 1

Summary of the content on the page No. 18

ILLUSTRATED PARTS BREAKDOWN ML150HPA Burner Assembly ODS/Pilot Assembly 18

Summary of the content on the page No. 19

This list contains replaceable parts for your heater. When ordering relacement PARTS LIST parts, following the instructions listed under Replacement Part on page17 of this ML150HPA manual. KEY ML150HPA NO. QTY PART NO. DESCRIPTION 1 1 MB11054 Cabinet Assembly 2 MB09052 1 Lower Front Panel Assembly 3 MB11053 1 Deflector Unit 4 MB19004 1 Burner Assembly 5 ND1808x400x9 1 ODS Pilot Assembly 5-1 ND0803-4 1 Thermocouple 5-2 ND0807 1 lgnitor Electrode 6 ML026-01 1 ODS

Summary of the content on the page No. 20

ILLUSTRATED PARTS BREAKDOWN ML250HPA ODS/Pilot Assembly Burner Assembly 20


Alternative user manuals
# User manual Category Download
1 Procom BLUE FLAME VENT-FREE MN100HBA User manual Gas Heater 1
2 Procom ML300HGA User manual Gas Heater 2
3 Procom BLUE FLAME VENT-FREE MN100TBA User manual Gas Heater 3
4 Procom ML150HPA User manual Gas Heater 1
5 Procom MN100HPA User manual Gas Heater 1
6 Procom ML250HPA User manual Gas Heater 3
7 Procom MN060HPA User manual Gas Heater 0
8 Procom MN100TPA User manual Gas Heater 0
9 Procom ML300TGA User manual Gas Heater 0
10 Procom BLUE FLAME VENT-FREE MN060HBA User manual Gas Heater 1
11 Allied Air Enterprises 506271-01 User manual Gas Heater 0
12 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
13 Breckwell ECONOMY P22FSL User manual Gas Heater 0
14 Breckwell ECONOMY P22FSA User manual Gas Heater 0
15 Breckwell ECONOMY P22I User manual Gas Heater 1