Summary of the content on the page No. 1
906388 - 10-28-02.qxd 10/28/02 11:47 AM Page 1
ESPAÑOL: PÁGINA 13
FRANÇAISE : PAGE 25
HIGH PRESSURE
Instruction
CLIPPED HEAD
manual
FRAMING NAILER
MODEL FCP350
IMPORTANT
Please make certain that the person who is
To learn more about Porter-Cable
visit our website at: to use this equipment carefully reads and
understands these instructions before
http://www.porter-cable.com
starting operations.
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in
Summary of the content on the page No. 2
906388 - 10-28-02.qxd 10/28/02 11:47 AM Page 2 ✦ ✦ PORTER CABLE Porter-Cable Corporation 4825 Highway 45 North Jackson, TN 38305 GB ENGLISH EC-DECLARATION OF CONFORMITY We declare under our sole responsibility that this product is in conformity with the regulations EN292-2: section 3 of 1992 EN292-1: section 5 of 1992 EN1050: 1993 EN792 13: 2000 E ESPANOL DECLARACION DE CONFORMIDAD ”CE” Declaramos bajo nuestra sola responsabilidad que est e producto está en conformidad con las regulaciones EN
Summary of the content on the page No. 3
906388 - 10-28-02.qxd 10/28/02 11:48 AM Page 3 GENERAL SAFETY RULES DANGER: When using pneumatic tools, basic safety precautions should always be followed to reduce the risk of personal injury, including the following: READ AND FOLLOW ALL INSTRUCTIONS. There are certain applications for which this tool was designed. Porter-Cable strongly recommends that this tool NOT be modified and/or used for any application other than for which it was designed. If you have any questions relative to its app
Summary of the content on the page No. 4
906388 - 10-28-02.qxd 10/28/02 11:49 AM Page 4 7. Wear ear protection to safe-guard Fig. 5 against possible hearing loss. Fig. 5. 8. Use clean, dry, regulated, com- pressed air at 80 to 150 PSI, (5.5 to 10.3 BAR). Fig. 6. 9. Do not connect tool to pressure which potentially exceeds 200 PSI (13.7 BAR). 10. Only use air hose that is rated for a maximum working pressure of at least 300 PSI (20.7 BAR) or 150% of the maximum Fig. 6 system pressure, which ever is greater. 11. Connect tool to air su
Summary of the content on the page No. 5
906388 - 10-28-02.qxd 10/28/02 11:50 AM Page 5 Fig. 11 Fig. 12 22. Do not overreach. Keep proper footing Fig. 13 and balance at all times when using or handling the tool. 23. Fire fasteners into work surface only: never into materials too hard to penetrate. Fig. 15. 24. Grip tool firmly to maintain control while allowing tool to recoil away from work surface as fastener is driven. In “Contact Actuation Mode” if safety element is allowed to recontact work surface before trigger is released an
Summary of the content on the page No. 6
906388 - 10-28-02.qxd 10/28/02 11:50 AM Page 6 TECHNICAL SPECIFICATIONS Noise level . . . . . . . . . . . . . . . . . . Typical Mean 2 A - Weighted sound impulse . . . effective Acceleration . . . . 4.9 m/s power level . . . . . . 105 dBA P - Emission sound pressure pressure level . . . . . . 98 dBA EMPLOYER’S RESPONSIBILITIES DANGER: Employer must enforce compliance with the safety warnings and all other instructions contained in this manual. Keep this manual available for use by all people
Summary of the content on the page No. 7
906388 - 10-28-02.qxd 10/28/02 11:50 AM Page 7 PREPARING THE TOOL 1. After reading and understanding this entire manual, connect tool to air supply (Fig. 18). DANGER: Never point tool at yourself or others in work area. Always connect tool to air supply before loading fasteners (Fig. 18). Do not load fasteners with trigger or safety depressed. Only use approved Porter-Cable fasteners. Operator and others in work area MUST wear safety glasses with side shields. Always wear ANSI Z87.1 approved
Summary of the content on the page No. 8
906388 - 10-28-02.qxd 10/28/02 11:50 AM Page 8 5. Pull the follower (B) Fig. 22, all the way to Fig. 23 the rear of the magazine and release. The A follower will apply pressure to the strip of nails to feed it into the driving mechanism. 6. Adjust directional exhaust deflector (A) Fig. 23, so that the exhaust air blast will be directed away from the operator. The exhaust deflector provides seven detented positions for directing the exhaust blast away from the operator. Grasp the deflector a
Summary of the content on the page No. 9
906388 - 10-28-02.qxd 10/28/02 11:50 AM Page 9 DANGER: Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing. Never carry tool with finger on trigger. In “Contact Actuation Mode” tool will fire a fastener if safety is bumped while trigger is depressed. Never point tool at yourself or others in work area. Never attempt to drive a fastener into material that is too hard, or at too steep an angle, or near the edge of the workpiece. The fastener can ricochet causin
Summary of the content on the page No. 10
906388 - 10-28-02.qxd 10/28/02 11:51 AM Page 10 CLEARING A JAMMED FASTENER 1. WARNING: Disconnect tool from air supply. 2. Remove any remaining fasteners from the nailer. A. Place finger in recess (A) Fig. 28, and depress lever to release follower mechanism. B. With follower release button (A) Fig. 28 depressed, slide follower all the way to the front of the magazine. C. Depress stop (B) Fig. 29, slide fasteners to the rear, and remove from magazine (see Fig. 22). 3. Use a pair of needle nose
Summary of the content on the page No. 11
906388 - 10-28-02.qxd 10/28/02 11:51 AM Page 11 MAINTENANCE CLEAN AND INSPECT DAILY WARNING: Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts. Inspect trigger and safety mechanism to assure system is complete and
Summary of the content on the page No. 12
906388 - 10-28-02.qxd 10/28/02 11:51 AM Page 12 ACCESSORIES A complete line of accessories is available from your Porter-CableDelta Supplier, Porter-CableDelta Factory Service Centers, and Porter-Cable Authorized Service Stations. Please visit our Web Site www.porter-cable.com for a catalog or for the name of your nearest supplier. WARNING: Since accessories, other than those offered by Porter-Cable Delta, have not been tested with this product, use of such accessories could be hazardous.
Summary of the content on the page No. 13
906388 - 10-28-02.qxd 10/28/02 11:51 AM Page 36 PORTER-CABLE DELTA SERVICE CENTERS (CENTROS DE SERVICIO DE PORTER-CABLE DELTA) (CENTRE DE SERVICE PORTER-CABLE DELTA) Parts and Repair Service for Porter-Cable Delta Power Tools are Available at These Locations (Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable Delta) (Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien) Cleveland 44125 ARIZON