Pentair Pool and SPA Heater PowerMax user manual

User manual for the device Pentair Pool and SPA Heater PowerMax

Device: Pentair Pool and SPA Heater PowerMax
Category: Swimming Pool Heater
Manufacturer: Pentair
Size: 2.14 MB
Added : 9/9/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pentair Pool and SPA Heater PowerMax. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pentair Pool and SPA Heater PowerMax.

For your convenience

If looking through the Pentair Pool and SPA Heater PowerMax user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pentair Pool and SPA Heater PowerMax on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pentair Pool and SPA Heater PowerMax to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pentair Pool and SPA Heater PowerMax User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pentair Pool and SPA Heater PowerMax but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pentair Pool and SPA Heater PowerMax. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1 1 1
® ™
MiniMax Plus and PowerMax
POOL & SPA HEATERS
OPERATION & INSTALLATION MANUAL
WARNING
FOR YOUR SAFETY - READ BEFORE OPERATING
Warning: If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury or loss of life.
For additional free copies of this manual; call (800) 831-7133.
To
Consumer
Retain For
Future
Reference
U.S. Patent Numbers
6,295,980
5,318,007 - 5,228,618
5,201,307 - 4,595,825
WARNING
Warning: Improper installatio

Summary of the content on the page No. 2

2 Table of Contents Introduction ............................................................................................................... 3 Important Notices ...................................................................................................................................................................... 3 Warranty Information .................................................................................................................................................

Summary of the content on the page No. 3

3 Introduction ® ™ MiniMax Plus and PowerMax * Pool and Spa Heaters Congratulations on your purchase of a MiniMax Plus high performance heating system. Proper installation and service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MiniMax Plus is a compact, lightweight and efficient gas fired high performance pool and spa heater that can be directly connected to schedule 40 PVC pipe and has a built-in top. The MiniMax Plus, also comes

Summary of the content on the page No. 4

Operation (contd.) 4 This instruction manual provides operating WARRANTY INFORMATION instructions, installation and service information for The MiniMax Plus pool heater is sold with a limited the MiniMax Plus high performance heater. The factory warranty. Specific details are described on information in this manual applies to the MiniMax the back cover of this manual and a copy of the Plus 150, 195, 200, 250, 300, 350, and 400 natural warranty and warranty registration card are gas and propane

Summary of the content on the page No. 5

Operation (contd.) 5 MINIMAX PLUS ELECTRONIC IGNITION LIGHTING/OPERATION - NATURAL GAS FOR YOUR SAFETY: READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage. Do not attempt to light the heater if you suspect a natural gas leak. Lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage. C. Use only your hand to push in or turn

Summary of the content on the page No. 6

Operation (contd.) 6 MINIMAX PLUS ELECTRONIC IGNITION LIGHTING/OPERATION - PROPANE FOR YOUR SAFETY: READ BEFORE LIGHTING NOTE The MiniMax Plus propane models have special features for additional safety and protection. Read the safety instructions for natural gas (page 5) before proceeding. WARNING If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage. Since propane gas is heavier than air, escaping propane wi

Summary of the content on the page No. 7

Operation (contd.) 7 MINIMAX PLUS MILLIVOLT LIGHTING/OPERATION-NATURAL GAS & PROPANE FOR YOUR SAFETY: READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage. Since propane gas is heavier than air, escaping propane will accumulate and remain at ground level. Do not attempt to light the heater. If you suspect a propane leak, lighting the heater can result in a fire or explosion which c

Summary of the content on the page No. 8

Operation (contd.) 8 OPERATING (CONTROLS) Dual Temperature Control System - (Electronic and Millivolt Models) For convenience and economy all MiniMax Plus heaters THERMOSTAT ADJUSTMENT are equipped with two thermostats on the front of the heater The knob with locking feature eliminates the need for control panel; see Figure 7. constant thermostat adjustments. Set the knob pointer to the desired pool or spa temperature. If further adjustment is needed, rotate the knob until the desired temperatur

Summary of the content on the page No. 9

Operation (contd.) 9 HEAT (HEAT) SERVICE (SERVICE) The heat light is on any time the thermostat has The service light is off during normal operation of signaled a call for heat which initializes the ignition heater. The light only comes on if a problem with a safety firing circuit -- the light comes on to indicate control has occurred or when the heater is first successful firing of the main burners. firing. The problem must be investigated by the serviceman prior to attempts to fire the heater

Summary of the content on the page No. 10

Operation (contd.) 10 TROUBLESHOOTING (CONTROLS) - Continued SYMBOL TABLE SWITCH OR DEVICE SWITCH OR DEVICE OPEN CIRCUIT CLOSED CIRCUIT LED LIT LED OFF (BLOCK CURRENT) (PASS CURRENT) IGNITION MODULE IND GND VAL GAS VALVE TRANSFORMER INCOMING CIRCUIT HI TEMP REMOTE PRESS TFUSE MV LINE VOLTAGE BREAKER LIMIT SWITCHES MV THERMOSTAT RELAY RMT PRESS HEAT PWR TSTAT HI TEMP TFUSE MV SRVE POWER THERM CLOSE IF NO MV SERVICE AUX THERMOSTAT CIRCUIT BOARD PRESS HEATER FIRING - NORMAL OPERATION HEAT FRONT PAN

Summary of the content on the page No. 11

11 Maintenance MAINTENANCE INSTRUCTIONS It is recommended that you check the following items at 3. Keep the heater area clear and free from least every six months and at the beginning of every combustibles and flammable liquids. swimming season. 1. Examine the venting system. Make sure there are no Relief Valve obstructions in the flow of combustion and ventila- In some installations, a tion air. relief valve is required 2. Visually inspect the main burner and the pilot burner on the MiniMax Plu

Summary of the content on the page No. 12

Maintenance (contd.) 12 12 RULE: 7.4 to 7.6 is a desirable pH range. It is essential CHEMICAL BALANCE to maintain correct pH, see Table 2. POOL AND SPA WATER If pH becomes too high (over alkaline), it Your Pentair Pool Products pool heater was designed has these effects: specifically for your spa or pool and will give you many 1. Greatly lowers the ability of chlorine to destroy years of trouble free service provided you keep your bacteria and algae. water chemistry in proper condition. 2. Wate

Summary of the content on the page No. 13

13 Installation Instructions SPECIFICATIONS IMPORTANT NOTICE: These installation instructions are designed for use by qualified personnel only, trained especially for installation of this type of heating equipment and related components. Some states require installation and repair by licensed personnel. If this applies in your state, be sure your contractor bears the appropriate license. Outdoor installation - stackless Mm odel"m A" Di "B" Di 1. 501. 7 7/8 in 6½ in TM HIGH PERFORMANCE HEATER 3

Summary of the content on the page No. 14

Installation (contd.) 14 WATER CONNECTIONS Reversible Inlet/Outlet Connection The MiniMax Plus heater is factory assembled with right side inlet/outlet water connections. The inlet/ TO PUMP outlet header can be reversed for left side water POOL FILTER POOL MANUAL ISOLATION connections without removing the heat exchanger. 3 BY-PASS HEATER VALVE CHECK 1 VALVE Reversing Water Connections ISOLATION VALVE CHECK Disassembly 2 1 Optional. VALVE FROM 2 Required when installation is below water level. PO

Summary of the content on the page No. 15

Installation (contd.) 15 WATER CONNECTIONS QUICK-FLANGE INSTALLATION INSTRUCTIONS Each MiniMax Plus Quick-Flange Accessory Kit contains the following items: One (1) Quick-Flange unit Two (2) 2 in. Rubber gaskets Four (4) 3/8 Bolts Four (4) 3/8 in. Washers Two (2) Plastic sleeves FOR 1½ & 2 in. SCHEDULE 40 PVC PIPE FOR 1½ & 2 in. COPPER PIPE Pipe Plastic Bushing Figure 13. Gasket/Sleeve Figure 15. Gasket 1. Insert plastic sleeves into the “Quick-Flange” inlet/outlet openings. NOTE 2. Slip the 2

Summary of the content on the page No. 16

16 16 Installation (contd.) GAS CONNECTIONS Table 7. Pipe Sized For Length Of Run In Equivalent Feet 1. /2 in.3. /4 in1. in1. ¼ in1. ½in 2 in GAS LINE INSTALLATIONS NP atLtNP aLtNP aLtNP aLtNP aLtNP a L Model Before installing the gas line, be sure to 1' 0'4' 05' 01' 501' 50600 ------ 150 check which gas the heater has been -'2' 03' 08' 01' 252' 504' 50600 ---- 195/200 designed to burn. This is important -'1' 02' 05' 07' 01' 502' 505' 00600 --- 250 because different types of gas require -- 1' 0'

Summary of the content on the page No. 17

DOOR Installation (contd.) 17 VENTILATION STACK TYPE OUTDOOR VENT KIT Mp odelV. ent CaP. roduct No Vent Dia OUTDOOR INSTALLATION ONLY 15 50O7 V14. 6023 6 in (See additional instructions for outdoor Power- 10 95/200O2 V24. 6022 7 in Max units in PowerMax Appendix) 25 50O3 V24. 6022 7 in For outdoor installation with built in vent top, the heater must be placed in a suitable area on a level, noncombus- 30 00O4 V34. 6022 8 in tible surface. Do not install the heater under an overhang 35 50O5 V34. 6

Summary of the content on the page No. 18

18 Installation (contd.) INDOOR INSTALLATION (USA ONLY) OUTDOOR SHELTER INSTALLATION (CANADA) (See additional instructions for outdoor PowerMax units in PowerMax Appendix) All products of combustion and vent gases must Installations in basements, garages, or be completely removed to the outside atmosphere underground structures where flammable liquids through a vent pipe which is connected to the may be stored must have the heater elevated 18 draft hood. A vent pipe extension of the same inches

Summary of the content on the page No. 19

Installation (contd.) 19 NOTE The heater requires two uninterrupted air supply b) Construct a non-combustible base from masonry openings; one for ventilation and one to supply blocks as illustrated, see Figure 23. oxygen for proper gas combustion. The air supply openings should be sized according to Tables 10. and 11. Air supply requirements below apply to all BASE FOR USE ON COMBUSTIBLE FLOORS MiniMax heaters, including PowerMax versions. All Air From Inside TM Air for Combustion Air Ventilatio

Summary of the content on the page No. 20

Installation (contd.) 20 Draft Hood INDOOR DRAFT HOOD INSTALLATION Top Cover 1. Take out the louvered outer top piece after first removing the sheet metal screws, attaching it to Adaptor the cabinet. Screw (2 PLC's) 2. Install the adaptor (vent kit). 3. Install the top cover (vent kit). 4. Install the draft hood (vent kit). Use the provided screws to secure the vent assembly. HEATER Figure 24. Transformer Wiring Instruction ELECTRICAL, IID ELECTRONIC UNITS Electrical Rating 60 Hz 115 V.A.C. or 2


Alternative user manuals
# User manual Category Download
1 Pentair 5001825 User manual Swimming Pool Heater 7
2 Pentair MASTERTEMP 300K BTU/HR User manual Swimming Pool Heater 15
3 Pentair MASTERTEMP 400K BTU/HR User manual Swimming Pool Heater 642
4 Pentair MASTERTEMP 200K BTU/HR User manual Swimming Pool Heater 15
5 Pentair MiniMax 200 User manual Swimming Pool Heater 31
6 Pentair 75 User manual Swimming Pool Heater 1
7 Pentair MASTERTEMP 250K BTU/HR User manual Swimming Pool Heater 267
8 Pentair MiniMax NT Standard Series User manual Swimming Pool Heater 36
9 Pentair MiniMax CH User manual Swimming Pool Heater 18
10 Pentair MT User manual Swimming Pool Heater 5
11 Pentair MT Sizes 500 User manual Swimming Pool Heater 4
12 Pentair INTELLIFLO 100 User manual Swimming Pool Heater 0
13 Pentair MiniMax 250 User manual Swimming Pool Heater 19
14 Pentair MiniMax Plus, PowerMax MiniMax Plus HP Series User manual Swimming Pool Heater 19
15 Pentair Purex Triton Minimax 300 User manual Swimming Pool Heater 60
16 Aquacal HP7 User manual Swimming Pool Heater 8
17 AquaPRO PRO1100e User manual Swimming Pool Heater 1
18 AquaPRO PRO400 User manual Swimming Pool Heater 10
19 AquaPRO PRO1300h/c User manual Swimming Pool Heater 5
20 AquaPRO PRO1300 User manual Swimming Pool Heater 20