Summary of the content on the page No. 1
DIGITAL WEATHER FORECASTER
MAIN FEATURES: MAIN UNIT
WITH REMOTE THERMO-HYGRO
H
SENSOR AND ALARM CLOCK
MODEL NO.: BAA182HG A
A1
USER’S MANUAL
C
B
D
INTRODUCTION
E
Congratulations on your purchase of the Weather forecaster with
F
cable free sensor and clock (BAR182HG).
G
This unit has a large four-line liquid crystal display (LCD) for
displaying weather forecast information, in/outdoor temperatures
and relative humidity, calendar clock, clock display of 2nd time-
zone and dual daily
Summary of the content on the page No. 2
A . FRONT DISPLAY CLOCK : A four line easy-to-read LCD I. [ ON / OFF ] BUTTON A1. WEATHER FORECAST WINDOW Enables or disables the daily alarms Graphically illustrates a weather forecast J. [ ] BUTTON Decreases the value of a setting B. [ ] BATTERY-LOW INDICATOR Activates when the remote-sensor or main unit battery power K. [ ] BUTTON is low Advances the value of a setting 1 2 C. [ ] / [ ] ALARM-ON ICONS TEMP. % RH ALARM : Appears when the alarm is activated L. [ ON / OFF ] BUTTON (
Summary of the content on the page No. 3
A. TWO-LINE LCD FEATURES: REMOTE THERMO-HYGRO Displays the current temperature and humidity monitored by SENSOR the remote unit B. LED INDICATOR Flashes when the remote sensor transmits a reading C. °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) D. CHANNEL SLIDE SWITCH Select the remote sensor Channel 1, Channel 2 or Channel 3 E. RESET Returns all user programmed settings to original factory set values F . BATTERY COMPARTMENT Accommodates two (2) UM-3 or AA-size batteries
Summary of the content on the page No. 4
easier synchronization between the transmission and reception BATTERY AND CHANNEL INSTALLATION: of signals. REMOTE UNIT 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is up to 30 The remote thermo-hygro sensor unit uses two (2) UM-3 or “AA” meters. size batteries. Note that the effective range is vastly affected by the building Follow these steps to install / replace batteries: materials and where the main and remote units are positi
Summary of the content on the page No. 5
Remote unit LOW BATTERY WARNING Wall-mount Table Stand When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the unit on a wall using the recessed screw hole. As for the remote unit, it comes with a wall-m
Summary of the content on the page No. 6
To force a signal search: To display temperature / humidity readings from a remote sensor: Press and hold [CHANNEL] & [MEM] for 2-seconds to enforce a 3-minute search. Press [CHANNEL] until the appropriate remote sensor channel is displayed in the box under the kinetic-wave. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the DISCONNECTED SIGNALS reading shown on the main unit and that on the re
Summary of the content on the page No. 7
HOW TO READ THE KINETIC WAVE THE COMFORT-LEVEL ICONS DISPLAY The comfort level indicators COM, WET or DRY will tell you if the current environment is comfortable, too wet or too dry. The kinetic wave display shows the signal receiving status of the main unit. There are three possible forms: The comfort indicator will appear on the display when the follow- ing conditions are satisfied: The unit is in searching mode. Indicator Shows that the Temperature Humidity displays Current Range Range on the
Summary of the content on the page No. 8
TEMPERATURE, HUMIDITY & PRESSURE MAXIMUM AND MINIMUM TEMPERATURE TREND INDICATORS AND HUMIDITY The temperature-trend, humidity-trend and pressure trend indicators The maximum and minimum recorded temperature and humidity show the trends of collected readings. Arrows indicate a rising, readings will automatically be stored in the memory. steady or falling trend. To display the maximum and minimum display memory: 1. Select the channel to be checked. Arrow indicator 2. Press [MEM] once to display t
Summary of the content on the page No. 9
The high-low displays are as follows: The respective HI, LO or both indicators will light up to signify the status of the alarm. Sequence Respective Display If in another channel other than channel one is selected, when the Pressing HI/LO once Enters HI temperature display alarm activates the display will switch to channel-1 and the display will flash. If left untouched, the alarm will activate for a 1-minute. Pressing HI/LO twice Enters HI humidity display Press [CHANNEL],[MEM],[HI/LO],[ ],[ ON
Summary of the content on the page No. 10
MODE 3. Hour-Minute-Day of the Week (of local time) Indicator Hour-Minute (of alternate time zone) displays on the unit Forecast Sunny Slightly Cloudy Rainy Cloudy MODE 4. Hour-Minute-Day of the Week (of second time zone) NOTE: Day-Month (of alternate time zone) 1. The accuracy of a general pressure-based weather forecast is about 70% to 75%. 2. The weather forecasts from this unit are predictions that cover the next 12 to 24 hours. It may not necessaril
Summary of the content on the page No. 11
The four-step crescendo function allows the alarm to start off gently For the 2nd time zone, which is indicated by the ZONE icon, enter and step up its intensity every 20 seconds for four times. Without the hour offset using the [ ] and [ ] (CLOCK) buttons and interruption, the alarm will go off for a total of two minutes. If no key the BAA182HG will calculate the second zone-time accordingly. is pressed to turn off the alarm within these 2 minutes, the alarm will If there is an item you do n
Summary of the content on the page No. 12
Temperature resolution : 0.2°F (0.1°C) MAINTENANCE Relative Humidity Operating : 25% RH to 90% RH range When handled properly, this unit is engineered to give you years of satisfactory service. Here are a few product care instructions: Remote thermo-hygro unit 1. Do not immerse the unit in water. If the unit comes in contact Proposed operating range : -4.0°F to 140.0°F with water, dry it immediately with a soft lint-free cloth. (-20.0°C to +60.0°C) 2. Do not clean the unit with abrasive or corro
Summary of the content on the page No. 13
Company Name: Oregon Scientific, Inc. NOTE ON COMPLIANCE Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA This device complies with Part 15 of the FCC Rules. Operation is Telephone Number: 1-800-853-8883 subject to the following two conditions: (1) This device may not Name and model number of the product: Weather Station cause harmful interference, and (2) This device must accept any BAA182HG interference received, including interference that may cause undesired operations. Warning: Ch
Summary of the content on the page No. 14
WARRANTY This product is warranted to be free of manufacturing defects for a period of 1 year from date of retail purchase. Defective product should be directed to the place of retail purchase for exchange. Should this not be possible, contact our customer care department for assistance and a return material authorization. No returns may be made without a return authorization. Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased. This warranty